Siemens AG 3RH2911-2FB11
Instantaneous
Категории:
Технические характеристики
| product brand name | SIRIUS |
|---|---|
| product category | Auxiliary switch |
| product designation | auxiliary switch |
| design of the product | for snapping onto the front |
| product type designation | 3RH29 |
| suitability for use | for 3RT2.1, 3RT2.2, 3RT2.3, 3RT2.4, 3RH2 |
| Напряжение питания | 690 V |
| Напряжение питания | 6 kV |
| General technical data – protection class IP on the front | IP20 |
| General technical data – mechanical service life (operating cycles) typical | 10 000 000 |
| General technical data – electrical endurance (operating cycles) at AC-15 at 230 V typical | 200 000 |
| General technical data – Substance Prohibitance (day/month/year) | 10/01/2009 |
| Масса | 0.049 g |
| General technical data – ● instantaneous contact | 0 |
| General technical data – ● lagging switching | 1 |
| General technical data – ● instantaneous contact (2) | 0 |
| General technical data – ● leading contact | 1 |
| General technical data – number of CO contacts of auxiliary contacts instantaneous contact | 0 |
| General technical data – operational current at AC-15 at 690 V rated value | 1 A |
| General technical data – ● at 24 V | 10 A |
| General technical data – ● at 230 V | 10 A |
| General technical data – ● at 125 V | 6 A |
| General technical data – ● at 250 V | 6 A |
| General technical data – operational current of auxiliary contacts at AC-12 maximum | 10 A |
| General technical data – ● at 24 V (2) | 6 A |
| General technical data – ● at 230 V (2) | 6 A |
| General technical data – ● at 400 V | 3 A |
| General technical data – ● at 24 V (3) | 10 A |
| General technical data – ● at 110 V | 3 A |
| General technical data – ● at 220 V | 1 A |
| General technical data – ● at 24 V rated value | 10 A |
| General technical data – ● at 60 V rated value | 10 A |
| General technical data – ● at 110 V rated value | 4 A |
| General technical data – ● at 220 V rated value | 2 A |
| General technical data – ● at 440 V rated value | 1.3 A |
| General technical data – ● at 600 V rated value | 0.65 A |
| General technical data – ● at 24 V rated value (2) | 10 A |
| General technical data – ● at 60 V rated value (2) | 10 A |
| General technical data – ● at 110 V rated value (2) | 10 A |
| General technical data – ● at 220 V rated value (2) | 3.6 A |
| General technical data – ● at 440 V rated value (2) | 2.5 A |
| General technical data – ● at 600 V rated value (2) | 1.8 A |
| General technical data – ● at 24 V rated value (3) | 10 A |
| General technical data – ● at 60 V rated value (3) | 3.5 A |
| General technical data – ● at 110 V rated value (3) | 1.3 A |
| General technical data – ● at 220 V rated value (3) | 0.9 A |
| General technical data – ● at 440 V rated value (3) | 0.2 A |
| General technical data – ● at 600 V rated value (3) | 0.1 A |
| General technical data – ● at 24 V rated value (4) | 10 A |
| General technical data – ● at 60 V rated value (4) | 4.7 A |
| General technical data – ● at 110 V rated value (4) | 3 A |
| General technical data – ● at 220 V rated value (4) | 1.2 A |
| General technical data – ● at 440 V rated value (4) | 0.5 A |
| General technical data – ● at 600 V rated value (4) | 0.26 A |
| General technical data – ● at 24 V (4) | 6 A |
| General technical data – ● at 48 V | 2 A |
| General technical data – ● at 60 V | 2 A |
| General technical data – ● at 110 V (2) | 1 A |
| General technical data – ● at 125 V (2) | 0.9 A |
| General technical data – ● at 220 V (2) | 0.3 A |
| General technical data – ● at 250 V (2) | 0.3 A |
| General technical data – design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V | C characteristic: 10 A; 0.4 kA |
| General technical data – contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| Ambient conditions – ● during operation | -25 ... +60 °C |
| Ambient conditions – ● during storage | -55 ... +80 °C |
| Safety related data – ● mirror contact according to IEC 60947-4-1 | No |
| Safety related data – ● positively driven operation according to IEC 60947-5-1 | No |
| Short-circuit protection – design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V | C characteristic: 10 A; 0.4 kA |
| Short-circuit protection – design of the fuse link for short-circuit protection of the auxiliary switch required | gG: 10 A (690 V, 1 kA) |
| Installation/ mounting/ dimensions – fastening method | snap-on mounting |
| Installation/ mounting/ dimensions – height | 41.5 mm |
| Installation/ mounting/ dimensions – width | 36 mm |
| Installation/ mounting/ dimensions – depth | 47.7 mm |
| Connections/ Terminals – type of electrical connection for auxiliary and control circuit | spring-loaded terminals |
| Connections/ Terminals – ● solid or stranded | 0.5 ... 2.5 mm² |
| Connections/ Terminals – ● finely stranded with core end processing | 0.5 ... 2.5 mm² |
| Connections/ Terminals – ● finely stranded without core end processing | 0.5 ... 2.5 mm² |
| Connections/ Terminals – — solid or stranded | 2x (0.5 ... 2.5 mm²) |
| Connections/ Terminals – — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) |
| Connections/ Terminals – — finely stranded without core end processing | 2x (0.5 ... 2.5 mm²) |
| Connections/ Terminals – ● for AWG cables for auxiliary contacts | 2x (20 ... 14) |
| Connections/ Terminals – AWG number as coded connectable conductor cross section for auxiliary contacts | 20 ... 14 |
| Сертификация | 0.34 kg |
| Сертификация | 0.562 kg |
| Сертификация | 0.0172 kg |
| Сертификация | 0.92 kg |