3RP2505-2AW30-0AX0

Siemens AG 3RP2505-2AW30-0AX0

Timing relays

  • Бренд: Siemens AG
  • Артикул (MPN): 3RP2505-2AW30-0AX0
  • Статус производства: Не определён

Категории:

Технические характеристики

product brand nameSIRIUS
product designationtiming relay
design of the product13 functions
product type designation3RP25
General technical data – product feature protective coating on printed-circuit boardYes; acc. to IPC-A-610
General technical data – ● relay outputYes
General technical data – ● semi-conductor outputNo
General technical data – product extension required remote controlNo
General technical data – product extension optional remote controlNo
General technical data – power loss [W] maximum2 W
Напряжение питания300 V
Напряжение питания2.5 kV
General technical data – degree of pollution3
Напряжение питания4 000 V
General technical data – shock resistance according to IEC 60068-2-2711 g / 15 ms
General technical data – vibration resistance according to IEC 60068-2-610 ... 55 Hz / 0.35 mm
General technical data – mechanical service life (operating cycles) typical10 000 000
General technical data – electrical endurance (operating cycles) at AC-15 at 230 V typical100 000
General technical data – adjustable time0.05 s ... 100 h
General technical data – relative setting accuracy relating to full-scale value5 %; +/-
General technical data – thermal current5 A
General technical data – ON period/maximum minimum35 ms
General technical data – recovery time250 ms
General technical data – reference code according to IEC 81346-2K
General technical data – relative repeat accuracy1 %; +/-
General technical data – influence of the surrounding temperature1% in the whole temperature range to the set runtime
General technical data – power supply influence1% in the whole voltage range to the set runtime
General technical data – Substance Prohibitance (day/month/year)09/12/2014
General technical data – SVHC substance name2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1
Масса0.107 kg
Напряжение питанияAC/DC
Control circuit/ Control – ● at 50 Hz rated value12 ... 240 V
Control circuit/ Control – ● at 60 Hz rated value12 ... 240 V
Control circuit/ Control – ● at 50 Hz12 ... 240 V
Control circuit/ Control – ● at 60 Hz12 ... 240 V
Напряжение питания50 ... 60 Hz
Напряжение питания12 ... 240 V
Напряжение питания12 ... 240 V
Control circuit/ Control – ● initial value0.8
Control circuit/ Control – ● full-scale value1.1
Control circuit/ Control – ● initial value (2)0.8
Control circuit/ Control – ● full-scale value (2)1.1
Control circuit/ Control – ● initial value (3)0.8
Control circuit/ Control – ● full-scale value (3)1.1
Control circuit/ Control – ● at 24 V0.4 A
Control circuit/ Control – ● at 240 V5 A
Control circuit/ Control – ● at 24 V (2)0.3 ms
Control circuit/ Control – ● at 240 V (2)0.5 ms
Switching Function – ● ON-delayYes
Switching Function – ● ON-delay/instantaneous contactNo
Switching Function – ● passing make contactYes
Switching Function – ● passing make contact/instantaneous contactNo
Switching Function – ● OFF delayNo
Switching Function – ● flashing symmetrically with interval start/instantaneousNo
Switching Function – ● flashing symmetrically with interval startYes
Switching Function – ● flashing symmetrically with pulse start/instantaneousNo
Switching Function – ● flashing symmetrically with pulse startYes
Switching Function – ● flashing asymmetrically with interval startNo
Switching Function – ● flashing asymmetrically with pulse startNo
Switching Function – ● star-delta circuit with delay timeNo
Switching Function – ● star-delta circuitNo
Switching Function – ● additive ON-delayYes
Switching Function – ● passing break contactYes
Switching Function – ● passing break contact/instantaneousNo
Switching Function – ● OFF delay (2)Yes
Switching Function – ● OFF delay/instantaneousNo
Switching Function – ● pulse delayedYes
Switching Function – ● pulse delayed/instantaneousNo
Switching Function – ● pulse-shapingYes
Switching Function – ● pulse-shaping/instantaneousNo
Switching Function – ● additive ON-delay/instantaneousNo
Switching Function – ● ON-delay/OFF-delay/instantaneousNo
Switching Function – ● passing make contact (2)Yes
Switching Function – ● passing make contact/instantaneous contact (2)No
Switching Function – ● retrotriggerable with deactivated control signal/instantaneous contactNo
Switching Function – ● retrotriggerable with switched-on control signalYes
Switching Function – ● retrotriggerable with switched-on control signal/instantaneous contactNo
Switching Function – ● retriggerable with deactivated control signalYes
Switching Function – design of the control terminal non-floatingYes
Short-circuit protection – design of the fuse link for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 4 A
МатериалAgSnO2
Auxiliary circuit – ● delayed switching0
Auxiliary circuit – ● instantaneous contact0
Auxiliary circuit – ● delayed switching (2)0
Auxiliary circuit – ● instantaneous contact (2)0
Auxiliary circuit – ● delayed switching (3)1
Auxiliary circuit – ● instantaneous contact (3)0
Auxiliary circuit – ● at 24 V3 A
Auxiliary circuit – ● at 250 V3 A
Auxiliary circuit – ● at 24 V (2)1 A
Auxiliary circuit – ● at 125 V0.2 A
Auxiliary circuit – ● at 250 V (2)0.1 A
Auxiliary circuit – operating frequency with 3RT2 contactor maximum5 000 1/h
Auxiliary circuit – contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
Auxiliary circuit – contact rating of auxiliary contacts according to ULR300 / B300
Auxiliary circuit – switching capacity current with inductive load0.01 ... 3 A
Inputs/ Outputs – ● at the relay outputs switchover delayed/without delayNo
Inputs/ Outputs – ● non-volatileNo
Inputs/ Outputs – ● at 24 V1 A
Inputs/ Outputs – ● at 125 V0.2 A
Electromagnetic compatibility – EMC emitted interference according to IEC 61812-1ambience A (industrial sector)
Electromagnetic compatibility – EMC immunity according to IEC 61812-1corresponds to degree of severity 3
Electromagnetic compatibility – ● due to burst according to IEC 61000-4-42 kV network connection / 1 kV control connection
Electromagnetic compatibility – ● due to conductor-earth surge according to IEC 61000-4-52 kV
Electromagnetic compatibility – ● due to conductor-conductor surge according to IEC 61000-4-51 kV
Electromagnetic compatibility – field-based interference according to IEC 61000-4-310 V/m
Electromagnetic compatibility – electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Safety related data – category according to EN 954-1none
Safety related data – protection class IP on the front according to IEC 60529IP20
Safety related data – type of insulationBasic insulation
Connections/ Terminals – product component removable terminal for auxiliary and control circuitYes
Connections/ Terminals – type of electrical connectionspring-loaded terminal (push-in)
Connections/ Terminals – ● for auxiliary and control circuitspring-loaded terminals (push-in)
Connections/ Terminals – ● solid1x (0.5 ... 4 mm²)
Connections/ Terminals – ● finely stranded with core end processing1x (0.5 ... 2.5 mm²)
Connections/ Terminals – ● finely stranded without core end processing0.5 ... 4 mm²
Connections/ Terminals – ● for AWG cables solid1x (20 ... 12)
Connections/ Terminals – ● for AWG cables stranded20 ... 12
Connections/ Terminals – ● solid (2)0.5 ... 4 mm²
Connections/ Terminals – ● finely stranded with core end processing (2)0.5 ... 4 mm²
Connections/ Terminals – ● finely stranded without core end processing (2)0.5 ... 4 mm²
Connections/ Terminals – ● solid (3)20 ... 12
Connections/ Terminals – ● stranded20 ... 14
Installation/ mounting/ dimensions – mounting positionany
Installation/ mounting/ dimensions – fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Installation/ mounting/ dimensions – height100 mm
Installation/ mounting/ dimensions – width17.5 mm
Installation/ mounting/ dimensions – depth90 mm
Installation/ mounting/ dimensions – — forwards0 mm
Installation/ mounting/ dimensions – — backwards0 mm
Installation/ mounting/ dimensions – — upwards0 mm
Installation/ mounting/ dimensions – — downwards0 mm
Installation/ mounting/ dimensions – — at the side0 mm
Installation/ mounting/ dimensions – — forwards (2)0 mm
Installation/ mounting/ dimensions – — backwards (2)0 mm
Installation/ mounting/ dimensions – — upwards (2)0 mm
Installation/ mounting/ dimensions – — at the side (2)0 mm
Installation/ mounting/ dimensions – — downwards (2)0 mm
Installation/ mounting/ dimensions – — forwards (3)0 mm
Installation/ mounting/ dimensions – — backwards (3)0 mm
Installation/ mounting/ dimensions – — upwards (3)0 mm
Installation/ mounting/ dimensions – — downwards (3)0 mm
Installation/ mounting/ dimensions – — at the side (3)0 mm
Ambient conditions – installation altitude at height above sea level maximum2 000 m
Ambient conditions – ● during operation-25 ... +60 °C
Ambient conditions – ● during storage-40 ... +85 °C
Ambient conditions – ● during transport-40 ... +85 °C
Ambient conditions – relative humidity during operation10 ... 95 %
Получить предложение по этой позиции