Siemens AG 3RT1363-6AP36
SIRIUS 3RT.3 contactors, 4-pole, up to 525 A
Категории:
Технические характеристики
| product brand name | SIRIUS |
|---|---|
| product designation | Contactor |
| product type designation | 3RT13 |
| General technical data – size of contactor | S10 |
| General technical data – ● function module for communication | No |
| General technical data – ● auxiliary switch | Yes |
| General technical data – ● at AC in hot operating state | 60 W |
| General technical data – ● at AC in hot operating state per pole | 15 W |
| General technical data – ● without load current share typical | 2.5 W |
| General technical data – type of calculation of power loss current-dependent | quadratic |
| General technical data – ● of main circuit with degree of pollution 3 rated value | 1 000 V |
| General technical data – ● of the auxiliary and control circuit with degree of pollution 3 rated value | 690 V |
| General technical data – ● of main circuit rated value | 8 kV |
| General technical data – ● of auxiliary circuit rated value | 6 kV |
| General technical data – reference code according to IEC 81346-2 | Q |
| General technical data – Substance Prohibitance (day/month/year) | 03/27/2017 |
| Масса | 4.011 kg |
| Ambient conditions – installation altitude at height above sea level maximum | 2 000 m |
| Ambient conditions – ● during operation | -40 ... +60 °C |
| Ambient conditions – ● during storage | -40 ... +70 °C |
| Ambient conditions – relative humidity minimum | 10 % |
| Ambient conditions – relative humidity at 55 °C according to IEC 60068-2-30 maximum | 95 % |
| Main circuit – number of poles for main current circuit | 4 |
| Main circuit – number of NO contacts for main contacts | 4 |
| Напряжение питания | AC |
| Рабочая температура | 275 A |
| Рабочая температура | 275 A |
| Рабочая температура | 250 A |
| Рабочая температура | 250 A |
| Рабочая температура | 225 A |
| Main circuit – — at 400 V rated value | 190 A |
| Main circuit – minimum cross-section in main circuit at maximum AC-1 rated value | 150 mm² |
| Main circuit – ● at AC-3 at 400 V rated value | 90 kW |
| Main circuit – ● at AC | 300 1/h |
| Main circuit – ● at DC | 300 1/h |
| Напряжение питания | AC |
| Напряжение питания | AC/DC |
| Control circuit/ Control – ● at 50 Hz rated value | 100 ... 250 V |
| Control circuit/ Control – ● at 60 Hz rated value | 100 ... 250 V |
| Напряжение питания | 100 ... 250 V |
| Control circuit/ Control – ● initial value | 0.8 |
| Control circuit/ Control – ● full-scale value | 1.1 |
| Control circuit/ Control – ● at 50 Hz | 0.85 ... 1.1 |
| Control circuit/ Control – ● at 60 Hz | 0.85 ... 1.1 |
| Control circuit/ Control – design of the surge suppressor | with varistor |
| Control circuit/ Control – ● at 50 Hz (2) | 220 V·A |
| Control circuit/ Control – ● at 60 Hz (2) | 220 V·A |
| Control circuit/ Control – ● at 50 Hz (3) | 7 V·A |
| Control circuit/ Control – ● at 60 Hz (3) | 7 V·A |
| Control circuit/ Control – closing power of magnet coil at DC | 190 W |
| Control circuit/ Control – holding power of magnet coil at DC | 2.5 W |
| Control circuit/ Control – ● at AC | 25 ... 60 ms |
| Control circuit/ Control – ● at DC | 25 ... 60 ms |
| Control circuit/ Control – ● at AC (2) | 45 ... 80 ms |
| Control circuit/ Control – ● at DC (2) | 45 ... 80 ms |
| Control circuit/ Control – control version of the switch operating mechanism | Standard A1 - A2 |
| Auxiliary circuit – number of NC contacts for auxiliary contacts | 2 |
| Auxiliary circuit – ● attachable | 2 |
| Auxiliary circuit – ● instantaneous contact | 2 |
| Auxiliary circuit – number of NO contacts for auxiliary contacts | 2 |
| Auxiliary circuit – ● attachable (2) | 2 |
| Auxiliary circuit – ● instantaneous contact (2) | 2 |
| Auxiliary circuit – ● at 230 V rated value | 4 A |
| Auxiliary circuit – ● at 400 V rated value | 3 A |
| Auxiliary circuit – ● at 500 V rated value | 2 A |
| Auxiliary circuit – ● at 690 V rated value | 2 A |
| Auxiliary circuit – ● at 24 V rated value | 3 A |
| Auxiliary circuit – ● at 48 V rated value | 1.5 A |
| Auxiliary circuit – ● at 110 V rated value | 0.55 A |
| Auxiliary circuit – ● at 125 V rated value | 0.55 A |
| Auxiliary circuit – ● at 220 V rated value | 0.3 A |
| UL/CSA ratings – contact rating of auxiliary contacts according to UL | A600 / Q300 |
| Short-circuit protection – — with type of coordination 2 required | gG: 355 A (500 V, 100 kA) |
| Short-circuit protection – ● for short-circuit protection of the auxiliary switch required | gG: 10 A (690 V, 1 kA) |
| Installation/ mounting/ dimensions – mounting position | For vertical mounting surface can be rotated +/-180°, and with 0° rotation can be tilted forward or backward +/- 30°, or standing |
| Installation/ mounting/ dimensions – fastening method side-by-side mounting | Yes |
| Installation/ mounting/ dimensions – fastening method | screw fixing |
| Installation/ mounting/ dimensions – height | 196 mm |
| Installation/ mounting/ dimensions – width | 140 mm |
| Installation/ mounting/ dimensions – depth | 153 mm |
| Installation/ mounting/ dimensions – — forwards | 20 mm |
| Installation/ mounting/ dimensions – — upwards | 10 mm |
| Installation/ mounting/ dimensions – — downwards | 10 mm |
| Installation/ mounting/ dimensions – — at the side | 0 mm |
| Installation/ mounting/ dimensions – — forwards (2) | 20 mm |
| Installation/ mounting/ dimensions – — upwards (2) | 10 mm |
| Installation/ mounting/ dimensions – — at the side (2) | 10 mm |
| Installation/ mounting/ dimensions – — downwards (2) | 10 mm |
| Installation/ mounting/ dimensions – — forwards (3) | 20 mm |
| Installation/ mounting/ dimensions – — upwards (3) | 10 mm |
| Installation/ mounting/ dimensions – — downwards (3) | 10 mm |
| Installation/ mounting/ dimensions – — at the side (3) | 10 mm |
| Масса | 3.85 kg |
| Connections/ Terminals – ● for main current circuit | Connection bar |
| Connections/ Terminals – ● for auxiliary and control circuit | screw-type terminals |
| Connections/ Terminals – ● at contactor for auxiliary contacts | Screw-type terminals |
| Connections/ Terminals – ● of magnet coil | screw terminal |
| Connections/ Terminals – ● solid or stranded | 1 ... 4 mm² |
| Connections/ Terminals – ● finely stranded with core end processing | 0.75 ... 2.5 mm² |
| Connections/ Terminals – — solid | 1x (1 ... 4mm²), 2x (1 ... 4mm²) |
| Connections/ Terminals – — solid or stranded | 1x (1 ... 4mm²), 2x (1 ... 4mm²) |
| Connections/ Terminals – — finely stranded with core end processing | 1x (0.75 ... 2.5 mm²), 2x (0.75 ... 2.5 mm²) |
| Connections/ Terminals – ● for AWG cables for auxiliary contacts | 1x (AWG 18 ... 14), 2x (AWG 18 ... 14) |
| Connections/ Terminals – AWG number as coded connectable conductor cross section for auxiliary contacts | 18 ... 14 |
| Safety related data – ● mirror contact according to IEC 60947-4-1 | Yes |
| Safety related data – ● positively driven operation according to IEC 60947-5-1 | No |
| Safety related data – protection class IP on the front according to IEC 60529 | IP00; IP20 with box terminal/cover |
| Safety related data – touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front with box terminal/cover |
| Communication/ Protocol – product function bus communication | No |