3RT1456-6AP36

Siemens AG 3RT1456-6AP36

SIRIUS 3RT.4 contactors for weak or non-inductive loads (AC-1), 3-pole up to 2 650 A

  • Бренд: Siemens AG
  • Артикул (MPN): 3RT1456-6AP36
  • Статус производства: Не определён

Категории:

Технические характеристики

product brand nameSIRIUS
product designationContactor
product type designation3RT14
General technical data – size of contactorS6
General technical data – ● function module for communicationNo
General technical data – ● auxiliary switchYes
General technical data – ● at AC in hot operating state86.4 W
General technical data – ● at AC in hot operating state per pole28.8 W
General technical data – ● without load current share typical5.2 W
General technical data – type of calculation of power loss current-dependentquadratic
General technical data – ● of main circuit with degree of pollution 3 rated value1 000 V
General technical data – ● of auxiliary circuit with degree of pollution 3 rated value500 V
General technical data – ● of main circuit rated value8 kV
General technical data – ● of auxiliary circuit rated value6 kV
General technical data – ● at AC8,5 g / 5 ms, 4,2 g / 10 ms
General technical data – ● at DC8,5 g / 5 ms, 4,2 g / 10 ms
General technical data – ● at AC (2)13,4 g / 5 ms, 6,5 g / 10 ms
General technical data – ● at DC (2)13,4 g / 5 ms, 6,5 g / 10 ms
General technical data – ● of contactor typical10 000 000
General technical data – ● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
General technical data – ● of the contactor with added auxiliary switch block typical10 000 000
General technical data – reference code according to IEC 81346-2Q
General technical data – Substance Prohibitance (day/month/year)05/01/2012
General technical data – SVHC substance nameLead CAS-No. 7439-92-1
Масса3.233 kg
Ambient conditions – installation altitude at height above sea level maximum2 000 m
Ambient conditions – ● during operation-25 ... +60 °C
Ambient conditions – ● during storage-55 ... +80 °C
Ambient conditions – relative humidity minimum10 %
Ambient conditions – relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit – number of poles for main current circuit3
Main circuit – number of NO contacts for main contacts3
Main circuit – number of NC contacts for main contacts0
Напряжение питанияAC
Рабочая температура275 A
Рабочая температура250 A
Рабочая температура250 A
Main circuit – — at 400 V rated value97 A
Main circuit – — at 690 V rated value97 A
Main circuit – minimum cross-section in main circuit at maximum AC-1 rated value140 mm²
Main circuit – — at 24 V rated value250 A
Main circuit – — at 60 V rated value250 A
Main circuit – — at 110 V rated value18 A
Main circuit – — at 220 V rated value3.4 A
Main circuit – — at 440 V rated value0.8 A
Main circuit – — at 600 V rated value0.5 A
Main circuit – — at 24 V rated value (2)250 A
Main circuit – — at 60 V rated value (2)250 A
Main circuit – — at 110 V rated value (2)250 A
Main circuit – — at 220 V rated value (2)20 A
Main circuit – — at 440 V rated value (2)3.2 A
Main circuit – — at 600 V rated value (2)1.6 A
Main circuit – — at 24 V rated value (3)250 A
Main circuit – — at 60 V rated value (3)250 A
Main circuit – — at 110 V rated value (3)250 A
Main circuit – — at 220 V rated value (3)250 A
Main circuit – — at 440 V rated value (3)11.5 A
Main circuit – — at 600 V rated value (3)4 A
Main circuit – — at 24 V rated value (4)250 A
Main circuit – — at 60 V rated value (4)7.5 A
Main circuit – — at 110 V rated value (4)2.5 A
Main circuit – — at 220 V rated value (4)0.6 A
Main circuit – — at 440 V rated value (4)0.17 A
Main circuit – — at 600 V rated value (4)0.12 A
Main circuit – — at 24 V rated value (5)250 A
Main circuit – — at 60 V rated value (5)250 A
Main circuit – — at 110 V rated value (5)250 A
Main circuit – — at 220 V rated value (5)2.5 A
Main circuit – — at 440 V rated value (5)0.65 A
Main circuit – — at 600 V rated value (5)0.37 A
Main circuit – — at 24 V rated value (6)250 A
Main circuit – — at 60 V rated value (6)250 A
Main circuit – — at 110 V rated value (6)250 A
Main circuit – — at 220 V rated value (6)250 A
Main circuit – — at 440 V rated value (6)1.4 A
Main circuit – — at 600 V rated value (6)0.75 A
Main circuit – ● at AC2 000 1/h
Main circuit – ● at DC2 000 1/h
Main circuit – ● at AC-1 maximum600 1/h
Напряжение питанияAC/DC
Напряжение питанияAC/DC
Control circuit/ Control – ● at 50 Hz rated value220 ... 240 V
Control circuit/ Control – ● at 60 Hz rated value220 ... 240 V
Напряжение питания220 ... 240 V
Control circuit/ Control – ● initial value0.8
Control circuit/ Control – ● full-scale value1.1
Control circuit/ Control – ● at 50 Hz0.8 ... 1.1
Control circuit/ Control – ● at 60 Hz0.8 ... 1.1
Control circuit/ Control – design of the surge suppressorwith varistor
Control circuit/ Control – — at 50 Hz250 V·A
Control circuit/ Control – — at 60 Hz250 V·A
Control circuit/ Control – — at 60 Hz (2)300 V·A
Control circuit/ Control – — at 50 Hz (2)300 V·A
Control circuit/ Control – ● at 50 Hz (2)300 V·A
Control circuit/ Control – ● at 50 Hz (3)0.9
Напряжение питания4.3 V·A
Напряжение питания5.2 V·A
Control circuit/ Control – — at 50 Hz (3)4.8 V·A
Control circuit/ Control – — at 60 Hz (3)4.8 V·A
Control circuit/ Control – — at 50 Hz (4)5.8 V·A
Control circuit/ Control – — at 60 Hz (4)5.8 V·A
Control circuit/ Control – ● at 50 Hz (4)5.8 V·A
Control circuit/ Control – ● at 50 Hz (5)0.8
Control circuit/ Control – closing power of magnet coil at DC360 W
Control circuit/ Control – holding power of magnet coil at DC5.2 W
Control circuit/ Control – ● at AC20 ... 95 ms
Control circuit/ Control – ● at DC20 ... 95 ms
Control circuit/ Control – ● at AC (2)40 ... 60 ms
Control circuit/ Control – ● at DC (2)40 ... 60 ms
Control circuit/ Control – arcing time10 ... 15 ms
Control circuit/ Control – control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit – number of NC contacts for auxiliary contacts2
Auxiliary circuit – ● attachable4
Auxiliary circuit – ● instantaneous contact2
Auxiliary circuit – number of NO contacts for auxiliary contacts2
Auxiliary circuit – ● attachable (2)4
Auxiliary circuit – ● instantaneous contact (2)2
Auxiliary circuit – operational current at AC-12 maximum10 A
Auxiliary circuit – ● at 230 V rated value6 A
Auxiliary circuit – ● at 400 V rated value3 A
Auxiliary circuit – ● at 500 V rated value2 A
Auxiliary circuit – ● at 690 V rated value1 A
Auxiliary circuit – ● at 24 V rated value10 A
Auxiliary circuit – ● at 48 V rated value2 A
Auxiliary circuit – ● at 60 V rated value2 A
Auxiliary circuit – ● at 110 V rated value1 A
Auxiliary circuit – ● at 125 V rated value0.9 A
Auxiliary circuit – ● at 220 V rated value0.3 A
Auxiliary circuit – ● at 600 V rated value0.1 A
Auxiliary circuit – contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
Short-circuit protection – design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
Short-circuit protection – — with type of coordination 1 requiredgG: 355 A (690 V, 100 kA)
Short-circuit protection – — with type of coordination 2 requiredgR: 350 A (690 V, 100 kA)
Short-circuit protection – ● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions – mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Installation/ mounting/ dimensions – fastening method side-by-side mountingYes
Installation/ mounting/ dimensions – fastening methodscrew fixing
Installation/ mounting/ dimensions – height172 mm
Installation/ mounting/ dimensions – width120 mm
Installation/ mounting/ dimensions – depth170 mm
Installation/ mounting/ dimensions – — forwards20 mm
Installation/ mounting/ dimensions – — upwards10 mm
Installation/ mounting/ dimensions – — downwards10 mm
Installation/ mounting/ dimensions – — at the side0 mm
Installation/ mounting/ dimensions – — forwards (2)20 mm
Installation/ mounting/ dimensions – — upwards (2)10 mm
Installation/ mounting/ dimensions – — at the side (2)10 mm
Installation/ mounting/ dimensions – — downwards (2)10 mm
Installation/ mounting/ dimensions – — forwards (3)20 mm
Installation/ mounting/ dimensions – — upwards (3)10 mm
Installation/ mounting/ dimensions – — downwards (3)10 mm
Installation/ mounting/ dimensions – — at the side (3)10 mm
Connections/ Terminals – ● for main current circuitConnection bar
Connections/ Terminals – ● for auxiliary and control circuitscrew-type terminals
Connections/ Terminals – ● at contactor for auxiliary contactsScrew-type terminals
Connections/ Terminals – ● of magnet coilscrew terminal
Connections/ Terminals – width of connection bar17 mm
Connections/ Terminals – thickness of connection bar3 mm
Connections/ Terminals – diameter of holes9 mm
Connections/ Terminals – number of holes1
Connections/ Terminals – ● for AWG cables for main contacts4 ... 250 kcmil
Connections/ Terminals – ● solid or stranded25 ... 120 mm²
Connections/ Terminals – ● stranded25 ... 120 mm²
Connections/ Terminals – ● solid or stranded (2)0.5 ... 4 mm²
Connections/ Terminals – ● finely stranded with core end processing0.5 ... 2.5 mm²
Connections/ Terminals – — solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Connections/ Terminals – — solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Connections/ Terminals – — finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Connections/ Terminals – ● for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
Connections/ Terminals – AWG number as coded connectable conductor cross section for auxiliary contacts18 ... 14
Safety related data – ● mirror contact according to IEC 60947-4-1Yes
Safety related data – ● positively driven operation according to IEC 60947-5-1No
Safety related data – service life maximum20 a
Safety related data – protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
Safety related data – touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover