product brand nameSIRIUS
product designationContactor
product type designation3RT14
General technical data – size of contactorS10
General technical data – ● function module for communicationNo
General technical data – ● auxiliary switchYes
General technical data – ● at AC in hot operating state105.6 W
General technical data – ● at AC in hot operating state per pole35.2 W
General technical data – ● without load current share typical3.4 W
General technical data – type of calculation of power loss current-dependentquadratic
General technical data – ● of main circuit with degree of pollution 3 rated value1 000 V
General technical data – ● of auxiliary circuit with degree of pollution 3 rated value500 V
General technical data – ● of main circuit rated value8 kV
General technical data – ● of auxiliary circuit rated value6 kV
General technical data – ● at AC8,5 g / 5 ms, 4,2 g / 10 ms
General technical data – ● at DC8,5 g / 5 ms, 4,2 g / 10 ms
General technical data – ● at AC (2)13,4 g / 5 ms, 6,5 g / 10 ms
General technical data – ● at DC (2)13,4 g / 5 ms, 6,5 g / 10 ms
General technical data – ● of contactor typical10 000 000
General technical data – ● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
General technical data – ● of the contactor with added auxiliary switch block typical10 000 000
General technical data – reference code according to IEC 81346-2Q
General technical data – Substance Prohibitance (day/month/year)03/01/2017
General technical data – SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Масса6.302 kg
Ambient conditions – installation altitude at height above sea level maximum2 000 m
Ambient conditions – ● during operation-25 ... +60 °C
Ambient conditions – ● during storage-55 ... +80 °C
Ambient conditions – relative humidity minimum10 %
Ambient conditions – relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit – number of poles for main current circuit3
Main circuit – number of NO contacts for main contacts3
Main circuit – number of NC contacts for main contacts0
Напряжение питанияAC
Рабочая температура400 A
Рабочая температура380 A
Рабочая температура380 A
Main circuit – — at 400 V rated value138 A
Main circuit – — at 690 V rated value138 A
Main circuit – minimum cross-section in main circuit at maximum AC-1 rated value240 mm²
Main circuit – — at 24 V rated value380 A
Main circuit – — at 60 V rated value380 A
Main circuit – — at 110 V rated value33 A
Main circuit – — at 220 V rated value3.8 A
Main circuit – — at 440 V rated value0.9 A
Main circuit – — at 600 V rated value0.6 A
Main circuit – — at 24 V rated value (2)380 A
Main circuit – — at 60 V rated value (2)380 A
Main circuit – — at 110 V rated value (2)380 A
Main circuit – — at 220 V rated value (2)380 A
Main circuit – — at 440 V rated value (2)4 A
Main circuit – — at 600 V rated value (2)2 A
Main circuit – — at 24 V rated value (3)380 A
Main circuit – — at 60 V rated value (3)380 A
Main circuit – — at 110 V rated value (3)380 A
Main circuit – — at 220 V rated value (3)380 A
Main circuit – — at 440 V rated value (3)11 A
Main circuit – — at 600 V rated value (3)5.2 A
Main circuit – — at 24 V rated value (4)380 A
Main circuit – — at 60 V rated value (4)11 A
Main circuit – — at 110 V rated value (4)3 A
Main circuit – — at 220 V rated value (4)0.6 A
Main circuit – — at 440 V rated value (4)0.18 A
Main circuit – — at 600 V rated value (4)0.125 A
Main circuit – — at 24 V rated value (5)380 A
Main circuit – — at 60 V rated value (5)380 A
Main circuit – — at 110 V rated value (5)380 A
Main circuit – — at 220 V rated value (5)2.5 A
Main circuit – — at 440 V rated value (5)0.65 A
Main circuit – — at 600 V rated value (5)0.37 A
Main circuit – — at 24 V rated value (6)380 A
Main circuit – — at 60 V rated value (6)380 A
Main circuit – — at 110 V rated value (6)380 A
Main circuit – — at 220 V rated value (6)380 A
Main circuit – — at 440 V rated value (6)1.4 A
Main circuit – — at 600 V rated value (6)0.75 A
Main circuit – ● at AC1 000 1/h
Main circuit – ● at DC1 000 1/h
Main circuit – ● at AC-1 maximum200 1/h
Напряжение питанияAC/DC
Напряжение питанияAC/DC
Control circuit/ Control – ● at 50 Hz rated value96 ... 127 V
Control circuit/ Control – ● at 60 Hz rated value96 ... 127 V
Напряжение питания96 ... 127 V
Control circuit/ Control – ● initial value0.8
Control circuit/ Control – ● full-scale value1.1
Control circuit/ Control – ● at 50 Hz0.8 ... 1.1
Control circuit/ Control – ● at 60 Hz0.8 ... 1.1
Control circuit/ Control – type of PLC-control input according to IEC 60947-1Type 1
Control circuit/ Control – consumed current at PLC-control input according to IEC 60947-1 maximum30 mA
Control circuit/ Control – design of the surge suppressorwith varistor
Control circuit/ Control – — at 50 Hz400 V·A
Control circuit/ Control – — at 60 Hz400 V·A
Control circuit/ Control – — at 60 Hz (2)530 V·A
Control circuit/ Control – — at 50 Hz (2)530 V·A
Control circuit/ Control – ● at 50 Hz (2)530 V·A
Control circuit/ Control – ● at 50 Hz (3)0.8
Напряжение питания2.8 V·A
Напряжение питания3.4 V·A
Control circuit/ Control – — at 50 Hz (3)5.5 V·A
Control circuit/ Control – — at 60 Hz (3)5.5 V·A
Control circuit/ Control – — at 50 Hz (4)8.5 V·A
Control circuit/ Control – — at 60 Hz (4)8.5 V·A
Control circuit/ Control – ● at 50 Hz (4)5 V·A
Control circuit/ Control – ● at 50 Hz (5)0.5
Control circuit/ Control – closing power of magnet coil at DC580 W
Control circuit/ Control – holding power of magnet coil at DC3.4 W
Control circuit/ Control – ● at AC60 ... 75 ms
Control circuit/ Control – ● at DC60 ... 75 ms
Control circuit/ Control – ● at AC (2)115 ... 130 ms
Control circuit/ Control – ● at DC (2)115 ... 130 ms
Control circuit/ Control – arcing time10 ... 15 ms
Control circuit/ Control – control version of the switch operating mechanismFail-safe PLC input (F-PLC-IN)
Auxiliary circuit – number of NC contacts for auxiliary contacts2
Auxiliary circuit – ● attachable4
Auxiliary circuit – ● instantaneous contact2
Auxiliary circuit – number of NO contacts for auxiliary contacts2
Auxiliary circuit – ● attachable (2)4
Auxiliary circuit – ● instantaneous contact (2)2
Auxiliary circuit – operational current at AC-12 maximum10 A
Auxiliary circuit – ● at 230 V rated value6 A
Auxiliary circuit – ● at 400 V rated value3 A
Auxiliary circuit – ● at 500 V rated value2 A
Auxiliary circuit – ● at 690 V rated value1 A
Auxiliary circuit – ● at 24 V rated value10 A
Auxiliary circuit – ● at 48 V rated value2 A
Auxiliary circuit – ● at 60 V rated value2 A
Auxiliary circuit – ● at 110 V rated value1 A
Auxiliary circuit – ● at 125 V rated value0.9 A
Auxiliary circuit – ● at 220 V rated value0.3 A
Auxiliary circuit – ● at 600 V rated value0.1 A
Auxiliary circuit – contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
Short-circuit protection – design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
Short-circuit protection – — with type of coordination 1 requiredgG: 500 A (690 V, 100 kA)
Short-circuit protection – — with type of coordination 2 requiredgR: 500 A (690 V, 100 kA)
Short-circuit protection – ● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions – mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Installation/ mounting/ dimensions – fastening method side-by-side mountingYes
Installation/ mounting/ dimensions – fastening methodscrew fixing
Installation/ mounting/ dimensions – height210 mm
Installation/ mounting/ dimensions – width145 mm
Installation/ mounting/ dimensions – depth202 mm
Installation/ mounting/ dimensions – — forwards20 mm
Installation/ mounting/ dimensions – — upwards10 mm
Installation/ mounting/ dimensions – — downwards10 mm
Installation/ mounting/ dimensions – — at the side0 mm
Installation/ mounting/ dimensions – — forwards (2)20 mm
Installation/ mounting/ dimensions – — upwards (2)10 mm
Installation/ mounting/ dimensions – — at the side (2)10 mm
Installation/ mounting/ dimensions – — downwards (2)10 mm
Installation/ mounting/ dimensions – — forwards (3)20 mm
Installation/ mounting/ dimensions – — upwards (3)10 mm
Installation/ mounting/ dimensions – — downwards (3)10 mm
Installation/ mounting/ dimensions – — at the side (3)10 mm
Connections/ Terminals – ● for main current circuitConnection bar
Connections/ Terminals – ● for auxiliary and control circuitscrew-type terminals
Connections/ Terminals – ● at contactor for auxiliary contactsScrew-type terminals
Connections/ Terminals – ● of magnet coilscrew terminal
Connections/ Terminals – width of connection bar25 mm
Connections/ Terminals – thickness of connection bar6 mm
Connections/ Terminals – diameter of holes11 mm
Connections/ Terminals – number of holes1
Connections/ Terminals – ● for AWG cables for main contacts2/0 ... 500 kcmil
Connections/ Terminals – ● solid or stranded70 ... 240 mm²
Connections/ Terminals – ● stranded70 ... 240 mm²
Connections/ Terminals – ● solid or stranded (2)0.5 ... 4 mm²
Connections/ Terminals – ● finely stranded with core end processing0.5 ... 2.5 mm²
Connections/ Terminals – — solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Connections/ Terminals – — solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Connections/ Terminals – — finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Connections/ Terminals – ● for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 1x 12
Connections/ Terminals – AWG number as coded connectable conductor cross section for auxiliary contacts18 ... 14
Safety related data – ● mirror contact according to IEC 60947-4-1Yes
Safety related data – ● positively driven operation according to IEC 60947-5-1No
Safety related data – ● suitable for safety functionYes
Safety related data – suitability for use safety-related switching OFFYes
Safety related data – safe stateoff
Safety related data – stop category according to IEC 60204-10
Safety related data – ● with low demand rate according to SN 3192040 %
Safety related data – ● with high demand rate according to SN 3192073 %
Safety related data – B10 value with high demand rate according to SN 319201 000 000
Safety related data – failure rate [FIT] with low demand rate according to SN 31920100 FIT
Safety related data – Safety Integrity Level (SIL) according to IEC 62061SIL 2
Safety related data – PFHD with high demand rate according to IEC 620614.5E-7 1/h
Safety related data – performance level (PL) according to ISO 13849-1PL c
Safety related data – category according to ISO 13849-12
Safety related data – device type according to ISO 13849-11
Safety related data – overdimensioning according to ISO 13849-2 necessaryYes
Safety related data – Safety Integrity Level (SIL) according to IEC 615082
Safety related data – safety device type according to IEC 61508-2Type B
Safety related data – PFHD with high demand rate according to IEC 615084.5E-7 1/h
Safety related data – PFDavg with low demand rate according to IEC 615080.007
Safety related data – Safe failure fraction (SFF)93 %
Safety related data – hardware fault tolerance according to IEC 615080
Safety related data – T1 value of service life according to IEC 6150820 a
Safety related data – protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
Safety related data – touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover