3RT2015-2AB01-ZW97

Siemens AG 3RT2015-2AB01-ZW97

Ordering Data Overview

  • Бренд: Siemens AG
  • Артикул (MPN): 3RT2015-2AB01-ZW97
  • Статус производства: Не определён

Технические характеристики

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data – size of contactorS00
General technical data – ● function module for communicationNo
General technical data – ● auxiliary switchYes
General technical data – ● at AC in hot operating state0.6 W
General technical data – ● at AC in hot operating state per pole0.2 W
General technical data – ● without load current share typical1.1 W
General technical data – type of calculation of power loss current-dependentquadratic
General technical data – ● of main circuit rated value6 kV
General technical data – ● of auxiliary circuit rated value6 kV
Напряжение питания400 V
General technical data – ● at AC6,7 g / 5 ms, 4,2 g / 10 ms
General technical data – ● at AC (2)10,5 g / 5 ms, 6,6 g / 10 ms
General technical data – ● of contactor typical30 000 000
General technical data – ● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
General technical data – ● of the contactor with added auxiliary switch block typical10 000 000
General technical data – reference code according to IEC 81346-2Q
General technical data – Substance Prohibitance (day/month/year)10/01/2009
Масса0.246 kg
Ambient conditions – installation altitude at height above sea level maximum2 000 m
Ambient conditions – ● during operation-25 ... +60 °C
Ambient conditions – ● during storage-55 ... +80 °C
Ambient conditions – relative humidity minimum10 %
Ambient conditions – relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit – number of poles for main current circuit3
Main circuit – number of NO contacts for main contacts3
Main circuit – number of NC contacts for main contacts0
Main circuit – ● at AC-3 rated value maximum690 V
Main circuit – ● at AC-3e rated value maximum690 V
Рабочая температура18 A
Рабочая температура18 A
Рабочая температура16 A
Main circuit – — at 400 V rated value7 A
Main circuit – — at 500 V rated value6 A
Main circuit – — at 690 V rated value4.9 A
Main circuit – — at 400 V rated value (2)7 A
Main circuit – — at 500 V rated value (2)6 A
Main circuit – — at 690 V rated value (2)4.9 A
Main circuit – ● at AC-4 at 400 V rated value6.5 A
Main circuit – ● at AC-5a up to 690 V rated value15.8 A
Main circuit – ● at AC-5b up to 400 V rated value5.8 A
Main circuit – — up to 230 V for current peak value n=20 rated value4 A
Main circuit – — up to 400 V for current peak value n=20 rated value4 A
Main circuit – — up to 500 V for current peak value n=20 rated value3.8 A
Main circuit – — up to 690 V for current peak value n=20 rated value3.6 A
Main circuit – — up to 230 V for current peak value n=30 rated value2.7 A
Main circuit – — up to 400 V for current peak value n=30 rated value2.7 A
Main circuit – — up to 500 V for current peak value n=30 rated value2.5 A
Main circuit – — up to 690 V for current peak value n=30 rated value2.4 A
Main circuit – minimum cross-section in main circuit at maximum AC-1 rated value2.5 mm²
Main circuit – ● at 400 V rated value2.6 A
Main circuit – ● at 690 V rated value1.8 A
Main circuit – — at 24 V rated value15 A
Main circuit – — at 60 V rated value15 A
Main circuit – — at 110 V rated value1.5 A
Main circuit – — at 220 V rated value0.6 A
Main circuit – — at 440 V rated value0.42 A
Main circuit – — at 600 V rated value0.42 A
Main circuit – — at 24 V rated value (2)15 A
Main circuit – — at 60 V rated value (2)15 A
Main circuit – — at 110 V rated value (2)8.4 A
Main circuit – — at 220 V rated value (2)1.2 A
Main circuit – — at 440 V rated value (2)0.6 A
Main circuit – — at 600 V rated value (2)0.5 A
Main circuit – — at 24 V rated value (3)15 A
Main circuit – — at 60 V rated value (3)15 A
Main circuit – — at 110 V rated value (3)15 A
Main circuit – — at 220 V rated value (3)15 A
Main circuit – — at 440 V rated value (3)0.9 A
Main circuit – — at 600 V rated value (3)0.7 A
Main circuit – — at 24 V rated value (4)15 A
Main circuit – — at 60 V rated value (4)0.35 A
Main circuit – — at 110 V rated value (4)0.1 A
Main circuit – — at 24 V rated value (5)15 A
Main circuit – — at 60 V rated value (5)3.5 A
Main circuit – — at 110 V rated value (5)0.25 A
Main circuit – — at 24 V rated value (6)15 A
Main circuit – — at 60 V rated value (6)15 A
Main circuit – — at 110 V rated value (6)15 A
Main circuit – — at 220 V rated value (4)1.2 A
Main circuit – — at 440 V rated value (4)0.14 A
Main circuit – — at 600 V rated value (4)0.14 A
Main circuit – ● at AC-2 at 400 V rated value3 kW
Main circuit – — at 230 V rated value1.5 kW
Main circuit – — at 400 V rated value (3)3 kW
Main circuit – — at 500 V rated value (3)3 kW
Main circuit – — at 690 V rated value (3)4 kW
Main circuit – — at 230 V rated value (2)1.5 kW
Main circuit – — at 400 V rated value (4)3 kW
Main circuit – — at 500 V rated value (4)3 kW
Main circuit – — at 690 V rated value (4)4 kW
Main circuit – ● at 400 V rated value (2)1.15 kW
Main circuit – ● at 690 V rated value (2)1.15 kW
Main circuit – ● up to 230 V for current peak value n=20 rated value1.5 kVA
Main circuit – ● up to 400 V for current peak value n=20 rated value2.7 kVA
Main circuit – ● up to 500 V for current peak value n=20 rated value3.3 kVA
Main circuit – ● up to 690 V for current peak value n=20 rated value4.3 kVA
Main circuit – ● up to 230 V for current peak value n=30 rated value1 kVA
Main circuit – ● up to 400 V for current peak value n=30 rated value1.8 kVA
Main circuit – ● up to 500 V for current peak value n=30 rated value2.2 kVA
Main circuit – ● up to 690 V for current peak value n=30 rated value2.9 kVA
Main circuit – ● limited to 1 s switching at zero current maximum120 A; Use minimum cross-section acc. to AC-1 rated value
Main circuit – ● limited to 5 s switching at zero current maximum86 A; Use minimum cross-section acc. to AC-1 rated value
Main circuit – ● limited to 10 s switching at zero current maximum67 A; Use minimum cross-section acc. to AC-1 rated value
Main circuit – ● limited to 30 s switching at zero current maximum52 A; Use minimum cross-section acc. to AC-1 rated value
Main circuit – ● limited to 60 s switching at zero current maximum43 A; Use minimum cross-section acc. to AC-1 rated value
Main circuit – ● at AC10 000 1/h
Main circuit – ● at AC-1 maximum1 000 1/h
Main circuit – ● at AC-2 maximum750 1/h
Main circuit – ● at AC-3 maximum750 1/h
Main circuit – — maximum750 1/h
Main circuit – ● at AC-4 maximum250 1/h
Напряжение питанияAC
Control circuit/ Control – ● at 50 Hz rated value24 V
Control circuit/ Control – ● at 60 Hz rated value24 V
Control circuit/ Control – ● at 50 Hz0.8 ... 1.1
Control circuit/ Control – ● at 60 Hz0.85 ... 1.1
Control circuit/ Control – ● at 50 Hz (2)27 V·A
Control circuit/ Control – ● at 60 Hz (2)24.3 V·A
Control circuit/ Control – ● at 50 Hz (3)0.8
Control circuit/ Control – ● at 60 Hz (3)0.75
Control circuit/ Control – ● at 50 Hz (4)4.2 V·A
Control circuit/ Control – ● at 60 Hz (4)3.3 V·A
Control circuit/ Control – ● at 50 Hz (5)0.25
Control circuit/ Control – ● at 60 Hz (5)0.25
Control circuit/ Control – ● at AC9 ... 35 ms
Control circuit/ Control – ● at AC (2)4 ... 15 ms
Control circuit/ Control – arcing time10 ... 15 ms
Control circuit/ Control – control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit – number of NC contacts for auxiliary contacts instantaneous contact0
Auxiliary circuit – number of NO contacts for auxiliary contacts instantaneous contact1
Auxiliary circuit – operational current at AC-12 maximum10 A
Auxiliary circuit – ● at 230 V rated value10 A
Auxiliary circuit – ● at 400 V rated value3 A
Auxiliary circuit – ● at 500 V rated value2 A
Auxiliary circuit – ● at 690 V rated value1 A
Auxiliary circuit – ● at 24 V rated value10 A
Auxiliary circuit – ● at 48 V rated value6 A
Auxiliary circuit – ● at 60 V rated value6 A
Auxiliary circuit – ● at 110 V rated value3 A
Auxiliary circuit – ● at 125 V rated value2 A
Auxiliary circuit – ● at 220 V rated value1 A
Auxiliary circuit – ● at 600 V rated value0.15 A
Auxiliary circuit – ● at 24 V rated value (2)10 A
Auxiliary circuit – ● at 48 V rated value (2)2 A
Auxiliary circuit – ● at 60 V rated value (2)2 A
Auxiliary circuit – ● at 110 V rated value (2)1 A
Auxiliary circuit – ● at 125 V rated value (2)0.9 A
Auxiliary circuit – ● at 220 V rated value (2)0.3 A
Auxiliary circuit – ● at 600 V rated value (2)0.1 A
Auxiliary circuit – contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings – ● at 480 V rated value4.8 A
UL/CSA ratings – ● at 600 V rated value6.1 A
UL/CSA ratings – — at 110/120 V rated value0.25 hp
UL/CSA ratings – — at 230 V rated value0.75 hp
UL/CSA ratings – — at 200/208 V rated value1.5 hp
UL/CSA ratings – — at 220/230 V rated value2 hp
UL/CSA ratings – — at 460/480 V rated value3 hp
UL/CSA ratings – — at 575/600 V rated value5 hp
UL/CSA ratings – contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection – design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
Short-circuit protection – — with type of coordination 1 requiredgG: 35 A (690 V,100 kA), aM: 20 A (690 V,100 kA), BS88: 35 A (415 V,80 kA)
Short-circuit protection – — with type of coordination 2 requiredgG: 20 A (690 V, 100 kA), aM: 16 A (690 V, 100 kA), BS88: 20 A (415 V, 80 kA)
Short-circuit protection – ● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions – mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
Installation/ mounting/ dimensions – fastening method side-by-side mountingYes
Installation/ mounting/ dimensions – fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Installation/ mounting/ dimensions – height70 mm
Installation/ mounting/ dimensions – width45 mm
Installation/ mounting/ dimensions – depth73 mm
Installation/ mounting/ dimensions – — forwards10 mm
Installation/ mounting/ dimensions – — upwards10 mm
Installation/ mounting/ dimensions – — downwards10 mm
Installation/ mounting/ dimensions – — at the side0 mm
Installation/ mounting/ dimensions – — forwards (2)10 mm
Installation/ mounting/ dimensions – — upwards (2)10 mm
Installation/ mounting/ dimensions – — at the side (2)6 mm
Installation/ mounting/ dimensions – — downwards (2)10 mm
Installation/ mounting/ dimensions – — forwards (3)10 mm
Installation/ mounting/ dimensions – — upwards (3)10 mm
Installation/ mounting/ dimensions – — downwards (3)10 mm
Installation/ mounting/ dimensions – — at the side (3)6 mm
Connections/ Terminals – ● for main current circuitspring-loaded terminals
Connections/ Terminals – ● for auxiliary and control circuitspring-loaded terminals
Connections/ Terminals – ● at contactor for auxiliary contactsSpring-type terminals
Connections/ Terminals – ● of magnet coilSpring-loaded terminal
Connections/ Terminals – — solid2x (0.5 ... 4 mm²)
Connections/ Terminals – — solid or stranded2x (0,5 ... 4 mm²)
Connections/ Terminals – — finely stranded with core end processing2x (0.5 ... 2.5 mm²)
Connections/ Terminals – — finely stranded without core end processing2x (0.5 ... 2.5 mm²)
Connections/ Terminals – ● for AWG cables for main contacts2x (20 ... 12)
Connections/ Terminals – ● solid0.5 ... 4 mm²
Connections/ Terminals – ● stranded0.5 ... 4 mm²
Connections/ Terminals – ● finely stranded with core end processing0.5 ... 2.5 mm²
Connections/ Terminals – ● finely stranded without core end processing0.5 ... 2.5 mm²
Connections/ Terminals – ● solid or stranded0.5 ... 4 mm²
Connections/ Terminals – ● finely stranded with core end processing (2)0.5 ... 2.5 mm²
Connections/ Terminals – ● finely stranded without core end processing (2)0.5 ... 2.5 mm²
Connections/ Terminals – — solid or stranded (2)2x (0,5 ... 4 mm²)
Connections/ Terminals – — finely stranded with core end processing (2)2x (0.5 ... 2.5 mm²)
Connections/ Terminals – — finely stranded without core end processing (2)2x (0.5 ... 2.5 mm²)
Connections/ Terminals – ● for AWG cables for auxiliary contacts2x (20 ... 12)
Connections/ Terminals – AWG number as coded connectable conductor cross section for main contacts20 ... 12
Connections/ Terminals – AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 12
Safety related data – ● mirror contact according to IEC 60947-4-1Yes; with 3RH29
Safety related data – ● positively driven operation according to IEC 60947-5-1No
Safety related data – ● suitable for safety functionYes
Safety related data – suitability for use safety-related switching OFFYes
Safety related data – service life maximum20 a
Safety related data – test wear-related service life necessaryYes
Safety related data – ● with low demand rate according to SN 3192040 %
Safety related data – ● with high demand rate according to SN 3192073 %
Safety related data – B10 value with high demand rate according to SN 319201 000 000
Safety related data – failure rate [FIT] with low demand rate according to SN 31920100 FIT
Safety related data – device type according to ISO 13849-13
Safety related data – overdimensioning according to ISO 13849-2 necessaryYes
Safety related data – safety device type according to IEC 61508-2Type A
Safety related data – protection class IP on the front according to IEC 60529IP20
Safety related data – touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Получить предложение по этой позиции