Siemens AG 3RT2017-1AB01-1AA0
SIRIUS 3RT contactors, 3-pole, up to 250 kW
Технические характеристики
| product brand name | SIRIUS |
|---|---|
| product designation | Power contactor |
| product type designation | 3RT2 |
| General technical data – size of contactor | S00 |
| General technical data – ● function module for communication | No |
| General technical data – ● auxiliary switch | Yes |
| General technical data – ● at AC in hot operating state | 1.5 W |
| General technical data – ● at AC in hot operating state per pole | 0.5 W |
| General technical data – ● without load current share typical | 1.5 W |
| General technical data – type of calculation of power loss current-dependent | quadratic |
| General technical data – ● of main circuit with degree of pollution 3 rated value | 690 V |
| General technical data – ● of auxiliary circuit with degree of pollution 3 rated value | 690 V |
| General technical data – ● of main circuit rated value | 6 kV |
| General technical data – ● of auxiliary circuit rated value | 6 kV |
| Напряжение питания | 400 V |
| General technical data – ● at AC | 7,3 g / 5 ms, 4,7 g / 10 ms |
| General technical data – ● at AC (2) | 11,4 g / 5 ms, 7,3 g / 10 ms |
| General technical data – ● of contactor typical | 30 000 000 |
| General technical data – ● of the contactor with added electronically optimized auxiliary switch block typical | 5 000 000 |
| General technical data – ● of the contactor with added auxiliary switch block typical | 10 000 000 |
| General technical data – reference code according to IEC 81346-2 | Q |
| General technical data – Substance Prohibitance (day/month/year) | 10/01/2009 |
| Масса | 0.227 kg |
| Ambient conditions – installation altitude at height above sea level maximum | 2 000 m |
| Ambient conditions – ● during operation | -25 ... +60 °C |
| Ambient conditions – ● during storage | -55 ... +80 °C |
| Ambient conditions – relative humidity minimum | 10 % |
| Ambient conditions – relative humidity at 55 °C according to IEC 60068-2-30 maximum | 95 % |
| Main circuit – number of poles for main current circuit | 3 |
| Main circuit – number of NO contacts for main contacts | 3 |
| Main circuit – number of NC contacts for main contacts | 0 |
| Main circuit – ● at AC-3 rated value maximum | 690 V |
| Main circuit – ● at AC-3e rated value maximum | 690 V |
| Рабочая температура | 22 A |
| Рабочая температура | 22 A |
| Рабочая температура | 20 A |
| Main circuit – — at 400 V rated value | 12 A |
| Main circuit – — at 500 V rated value | 9.2 A |
| Main circuit – — at 690 V rated value | 6.7 A |
| Main circuit – — at 400 V rated value (2) | 12 A |
| Main circuit – — at 500 V rated value (2) | 9.2 A |
| Main circuit – — at 690 V rated value (2) | 6.7 A |
| Main circuit – ● at AC-4 at 400 V rated value | 8.5 A |
| Main circuit – ● at AC-5a up to 690 V rated value | 19.4 A |
| Main circuit – ● at AC-5b up to 400 V rated value | 9.9 A |
| Main circuit – — up to 230 V for current peak value n=20 rated value | 7.2 A |
| Main circuit – — up to 400 V for current peak value n=20 rated value | 7.2 A |
| Main circuit – — up to 500 V for current peak value n=20 rated value | 7.2 A |
| Main circuit – — up to 690 V for current peak value n=20 rated value | 6.7 A |
| Main circuit – — up to 230 V for current peak value n=30 rated value | 4.8 A |
| Main circuit – — up to 400 V for current peak value n=30 rated value | 4.8 A |
| Main circuit – — up to 500 V for current peak value n=30 rated value | 4.8 A |
| Main circuit – — up to 690 V for current peak value n=30 rated value | 4.8 A |
| Main circuit – minimum cross-section in main circuit at maximum AC-1 rated value | 4 mm² |
| Main circuit – ● at 400 V rated value | 4.1 A |
| Main circuit – ● at 690 V rated value | 3.3 A |
| Main circuit – — at 24 V rated value | 20 A |
| Main circuit – — at 60 V rated value | 20 A |
| Main circuit – — at 110 V rated value | 2.1 A |
| Main circuit – — at 220 V rated value | 0.8 A |
| Main circuit – — at 440 V rated value | 0.6 A |
| Main circuit – — at 600 V rated value | 0.6 A |
| Main circuit – — at 24 V rated value (2) | 20 A |
| Main circuit – — at 60 V rated value (2) | 20 A |
| Main circuit – — at 110 V rated value (2) | 12 A |
| Main circuit – — at 220 V rated value (2) | 1.6 A |
| Main circuit – — at 440 V rated value (2) | 0.8 A |
| Main circuit – — at 600 V rated value (2) | 0.7 A |
| Main circuit – — at 24 V rated value (3) | 20 A |
| Main circuit – — at 60 V rated value (3) | 20 A |
| Main circuit – — at 110 V rated value (3) | 20 A |
| Main circuit – — at 220 V rated value (3) | 20 A |
| Main circuit – — at 440 V rated value (3) | 1.3 A |
| Main circuit – — at 600 V rated value (3) | 1 A |
| Main circuit – — at 24 V rated value (4) | 20 A |
| Main circuit – — at 60 V rated value (4) | 0.5 A |
| Main circuit – — at 110 V rated value (4) | 0.15 A |
| Main circuit – — at 24 V rated value (5) | 20 A |
| Main circuit – — at 60 V rated value (5) | 5 A |
| Main circuit – — at 110 V rated value (5) | 0.35 A |
| Main circuit – — at 24 V rated value (6) | 20 A |
| Main circuit – — at 60 V rated value (6) | 20 A |
| Main circuit – — at 110 V rated value (6) | 20 A |
| Main circuit – — at 220 V rated value (4) | 1.5 A |
| Main circuit – — at 440 V rated value (4) | 0.2 A |
| Main circuit – — at 600 V rated value (4) | 0.2 A |
| Main circuit – ● at AC-2 at 400 V rated value | 5.5 kW |
| Main circuit – — at 230 V rated value | 3 kW |
| Main circuit – — at 400 V rated value (3) | 5.5 kW |
| Main circuit – — at 500 V rated value (3) | 5.5 kW |
| Main circuit – — at 690 V rated value (3) | 5.5 kW |
| Main circuit – — at 230 V rated value (2) | 3 kW |
| Main circuit – — at 400 V rated value (4) | 5.5 kW |
| Main circuit – — at 500 V rated value (4) | 5.5 kW |
| Main circuit – — at 690 V rated value (4) | 5.5 kW |
| Main circuit – ● at 400 V rated value (2) | 2 kW |
| Main circuit – ● at 690 V rated value (2) | 2.5 kW |
| Main circuit – ● up to 230 V for current peak value n=20 rated value | 2.8 kVA |
| Main circuit – ● up to 400 V for current peak value n=20 rated value | 4.9 kVA |
| Main circuit – ● up to 500 V for current peak value n=20 rated value | 6.2 kVA |
| Main circuit – ● up to 690 V for current peak value n=20 rated value | 8 kVA |
| Main circuit – ● up to 230 V for current peak value n=30 rated value | 1.9 kVA |
| Main circuit – ● up to 400 V for current peak value n=30 rated value | 3.3 kVA |
| Main circuit – ● up to 500 V for current peak value n=30 rated value | 4.1 kVA |
| Main circuit – ● up to 690 V for current peak value n=30 rated value | 5.7 kVA |
| Main circuit – ● limited to 1 s switching at zero current maximum | 200 A; Use minimum cross-section acc. to AC-1 rated value |
| Main circuit – ● limited to 5 s switching at zero current maximum | 123 A; Use minimum cross-section acc. to AC-1 rated value |
| Main circuit – ● limited to 10 s switching at zero current maximum | 96 A; Use minimum cross-section acc. to AC-1 rated value |
| Main circuit – ● limited to 30 s switching at zero current maximum | 74 A; Use minimum cross-section acc. to AC-1 rated value |
| Main circuit – ● limited to 60 s switching at zero current maximum | 61 A; Use minimum cross-section acc. to AC-1 rated value |
| Main circuit – ● at AC | 10 000 1/h |
| Main circuit – ● at AC-1 maximum | 1 000 1/h |
| Main circuit – ● at AC-2 maximum | 750 1/h |
| Main circuit – ● at AC-3 maximum | 750 1/h |
| Main circuit – — maximum | 750 1/h |
| Main circuit – ● at AC-4 maximum | 250 1/h |
| Напряжение питания | AC |
| Control circuit/ Control – ● at 50 Hz rated value | 24 V |
| Control circuit/ Control – ● at 60 Hz rated value | 24 V |
| Control circuit/ Control – ● at 50 Hz | 0.8 ... 1.1 |
| Control circuit/ Control – ● at 60 Hz | 0.85 ... 1.1 |
| Control circuit/ Control – ● at 50 Hz (2) | 37 V·A |
| Control circuit/ Control – ● at 60 Hz (2) | 33 V·A |
| Control circuit/ Control – ● at 50 Hz (3) | 0.8 |
| Control circuit/ Control – ● at 60 Hz (3) | 0.75 |
| Control circuit/ Control – ● at 50 Hz (4) | 5.7 V·A |
| Control circuit/ Control – ● at 60 Hz (4) | 4.4 V·A |
| Control circuit/ Control – ● at 50 Hz (5) | 0.25 |
| Control circuit/ Control – ● at 60 Hz (5) | 0.25 |
| Control circuit/ Control – ● at AC | 9 ... 35 ms |
| Control circuit/ Control – ● at AC (2) | 4 ... 15 ms |
| Control circuit/ Control – arcing time | 10 ... 15 ms |
| Control circuit/ Control – control version of the switch operating mechanism | Standard A1 - A2 |
| Auxiliary circuit – number of NC contacts for auxiliary contacts instantaneous contact | 0 |
| Auxiliary circuit – number of NO contacts for auxiliary contacts instantaneous contact | 1 |
| Auxiliary circuit – operational current at AC-12 maximum | 10 A |
| Auxiliary circuit – ● at 230 V rated value | 10 A |
| Auxiliary circuit – ● at 400 V rated value | 3 A |
| Auxiliary circuit – ● at 500 V rated value | 2 A |
| Auxiliary circuit – ● at 690 V rated value | 1 A |
| Auxiliary circuit – ● at 24 V rated value | 10 A |
| Auxiliary circuit – ● at 48 V rated value | 6 A |
| Auxiliary circuit – ● at 60 V rated value | 6 A |
| Auxiliary circuit – ● at 110 V rated value | 3 A |
| Auxiliary circuit – ● at 125 V rated value | 2 A |
| Auxiliary circuit – ● at 220 V rated value | 1 A |
| Auxiliary circuit – ● at 600 V rated value | 0.15 A |
| Auxiliary circuit – ● at 24 V rated value (2) | 10 A |
| Auxiliary circuit – ● at 48 V rated value (2) | 2 A |
| Auxiliary circuit – ● at 60 V rated value (2) | 2 A |
| Auxiliary circuit – ● at 110 V rated value (2) | 1 A |
| Auxiliary circuit – ● at 125 V rated value (2) | 0.9 A |
| Auxiliary circuit – ● at 220 V rated value (2) | 0.3 A |
| Auxiliary circuit – ● at 600 V rated value (2) | 0.1 A |
| Auxiliary circuit – contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| UL/CSA ratings – ● at 480 V rated value | 11 A |
| UL/CSA ratings – ● at 600 V rated value | 11 A |
| UL/CSA ratings – — at 110/120 V rated value | 0.5 hp |
| UL/CSA ratings – — at 230 V rated value | 2 hp |
| UL/CSA ratings – — at 200/208 V rated value | 3 hp |
| UL/CSA ratings – — at 220/230 V rated value | 3 hp |
| UL/CSA ratings – — at 460/480 V rated value | 8 hp |
| UL/CSA ratings – — at 575/600 V rated value | 10 hp |
| UL/CSA ratings – contact rating of auxiliary contacts according to UL | A600 / Q600 |
| Short-circuit protection – design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V | C characteristic: 10 A; 0.4 kA |
| Short-circuit protection – — with type of coordination 1 required | gG: 50 A (690 V,100 kA), aM: 20 A (690 V,100 kA), BS88: 35 A (415 V,80 kA) |
| Short-circuit protection – — with type of coordination 2 required | gG: 20 A (690 V, 100 kA), aM: 16 A (690 V, 100 kA), BS88: 20 A (415 V, 80 kA) |
| Short-circuit protection – ● for short-circuit protection of the auxiliary switch required | gG: 10 A (500 V, 1 kA) |
| Installation/ mounting/ dimensions – mounting position | standing, on horizontal mounting surface |
| Installation/ mounting/ dimensions – fastening method side-by-side mounting | Yes |
| Installation/ mounting/ dimensions – fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| Installation/ mounting/ dimensions – height | 58 mm |
| Installation/ mounting/ dimensions – width | 45 mm |
| Installation/ mounting/ dimensions – depth | 73 mm |
| Installation/ mounting/ dimensions – — forwards | 10 mm |
| Installation/ mounting/ dimensions – — upwards | 10 mm |
| Installation/ mounting/ dimensions – — downwards | 10 mm |
| Installation/ mounting/ dimensions – — at the side | 0 mm |
| Installation/ mounting/ dimensions – — forwards (2) | 10 mm |
| Installation/ mounting/ dimensions – — upwards (2) | 10 mm |
| Installation/ mounting/ dimensions – — at the side (2) | 6 mm |
| Installation/ mounting/ dimensions – — downwards (2) | 10 mm |
| Installation/ mounting/ dimensions – — forwards (3) | 10 mm |
| Installation/ mounting/ dimensions – — upwards (3) | 10 mm |
| Installation/ mounting/ dimensions – — downwards (3) | 10 mm |
| Installation/ mounting/ dimensions – — at the side (3) | 6 mm |
| Connections/ Terminals – ● for main current circuit | screw-type terminals |
| Connections/ Terminals – ● for auxiliary and control circuit | screw-type terminals |
| Connections/ Terminals – ● at contactor for auxiliary contacts | Screw-type terminals |
| Connections/ Terminals – ● of magnet coil | screw terminal |
| Connections/ Terminals – — solid | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² |
| Connections/ Terminals – — solid or stranded | 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm² |
| Connections/ Terminals – — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| Connections/ Terminals – ● for AWG cables for main contacts | 2x (20 ... 16), 2x (18 ... 14), 2x 12 |
| Connections/ Terminals – ● solid | 0.5 ... 4 mm² |
| Connections/ Terminals – ● stranded | 0.5 ... 4 mm² |
| Connections/ Terminals – ● finely stranded with core end processing | 0.5 ... 2.5 mm² |
| Connections/ Terminals – ● solid or stranded | 0.5 ... 4 mm² |
| Connections/ Terminals – ● finely stranded with core end processing (2) | 0.5 ... 2.5 mm² |
| Connections/ Terminals – — solid or stranded (2) | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² |
| Connections/ Terminals – — finely stranded with core end processing (2) | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
| Connections/ Terminals – ● for AWG cables for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14), 2x 12 |
| Connections/ Terminals – AWG number as coded connectable conductor cross section for main contacts | 20 ... 12 |
| Connections/ Terminals – AWG number as coded connectable conductor cross section for auxiliary contacts | 20 ... 12 |
| Safety related data – ● mirror contact according to IEC 60947-4-1 | Yes; with 3RH29 |
| Safety related data – ● positively driven operation according to IEC 60947-5-1 | No |
| Safety related data – ● suitable for safety function | Yes |
| Safety related data – suitability for use safety-related switching OFF | Yes |
| Safety related data – service life maximum | 20 a |
| Safety related data – test wear-related service life necessary | Yes |
| Safety related data – ● with low demand rate according to SN 31920 | 40 % |
| Safety related data – ● with high demand rate according to SN 31920 | 73 % |
| Safety related data – B10 value with high demand rate according to SN 31920 | 1 000 000 |
| Safety related data – failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT |
| Safety related data – device type according to ISO 13849-1 | 3 |
| Safety related data – overdimensioning according to ISO 13849-2 necessary | Yes |
| Safety related data – safety device type according to IEC 61508-2 | Type A |
| Safety related data – protection class IP on the front according to IEC 60529 | IP20 |
| Safety related data – touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
| Сертификация | 1.18 kg |
| Сертификация | 38.5 kg |
| Сертификация | -0.155 kg |
| Сертификация | 39.6 kg |