Автоматические выключатели защиты электродвигателей
SI

Siemens AG 3RV2011-1FA15-0BA0

Автоматический выключатель защиты двигателя Siemens 3RV2011-1FA15-0BA0, серия 3RV2. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.

  • Бренд: Siemens AG
  • Артикул (MPN): 3RV2011-1FA15-0BA0
  • Серия: 3RV2 Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationspecial type circuit breaker frame size S00 for motor protection, Class 10 thermal release 3.5...5 A short-circuit release 65 A screw terminal standard switching capacity with transverse auxiliary switch 1 NO+1 NC ambient temperature -50 °C 500 operating cycles
product brand nameSIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV2
General technical data / product function disconnector functionalityYes
General technical data / product extension auxiliary switchYes
General technical data / power loss [W] for rated value of the current / at AC in hot operating state7.25 W
General technical data / power loss [W] for rated value of the current / at AC in hot operating state per pole2.4 W
General technical data / type of calculation of power loss current-dependentquadratic
Напряжение питания690 V
Напряжение питания6 kV
Напряжение питания400 V
General technical data / protection class IP / on the frontIP20
General technical data / protection class IP / of the terminalIP20
General technical data / shock resistance according to IEC 60068-2-2725g / 11 ms
General technical data / mechanical service life (operating cycles) / of the main contacts typical500
General technical data / mechanical service life (operating cycles) / of auxiliary contacts typical500
General technical data / electrical endurance (operating cycles) typical500
General technical data / reference code according to IEC 81346-2Q
General technical data / continuous current rated value5 A
General technical data / Substance Prohibitance (day/month/year)10/01/2009
Масса0.345 kg
Ambient conditions / installation altitude at height above sea level maximum2 000 m
Рабочая температура-50 ... +60 °C
Ambient conditions / ambient temperature / during storage-50 ... +80 °C
Рабочая температура-50 ... +80 °C
Ambient conditions / temperature compensation-20 ... +60 °C
Ambient conditions / relative humidity during operation10 ... 95 %
Напряжение питания690 V
Напряжение питания20 ... 690 V
Напряжение питания690 V
Main circuit / operating frequency rated value50 ... 60 Hz
Main circuit / operational current rated value5 A
Main circuit / operational current / at AC-3 at 400 V rated value5 A
Main circuit / operating power / at AC-3 / at 230 V rated value1.1 kW
Main circuit / operating power / at AC-3 / at 400 V rated value1.5 kW
Main circuit / operating power / at AC-3 / at 500 V rated value2.2 kW
Main circuit / operating power / at AC-3 / at 690 V rated value4 kW
Main circuit / operating frequency / at AC-3 maximum15 1/h
Auxiliary circuit / design of the auxiliary switchtransverse
Напряжение питанияAC/DC
Auxiliary circuit / number of NC contacts for auxiliary contacts1
Auxiliary circuit / number of NO contacts for auxiliary contacts1
Auxiliary circuit / number of CO contacts for auxiliary contacts0
Auxiliary circuit / operational current of auxiliary contacts at AC-15 / at 24 V2 A
Auxiliary circuit / operational current of auxiliary contacts at AC-15 / at 120 V0.5 A
Auxiliary circuit / operational current of auxiliary contacts at AC-15 / at 125 V0.5 A
Auxiliary circuit / operational current of auxiliary contacts at AC-15 / at 230 V0.5 A
Auxiliary circuit / operational current of auxiliary contacts at DC-13 / at 24 V1 A
Auxiliary circuit / operational current of auxiliary contacts at DC-13 / at 60 V0.15 A
Protective and monitoring functions / product function / ground fault detectionNo
Protective and monitoring functions / product function / phase failure detectionYes
Protective and monitoring functions / trip classCLASS 10
Protective and monitoring functions / design of the overload releasethermal
Protective and monitoring functions / protection function thermal overload protection (ANSI 49)Yes
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 240 V rated value100 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 400 V rated value100 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 500 V rated value100 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 690 V rated value6 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 240 V rated value100 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 400 V rated value100 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 500 V rated value100 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 690 V rated value4 kA
Protective and monitoring functions / response value current of instantaneous short-circuit trip unit65 A
Short-circuit protection / product function short circuit protectionYes
Short-circuit protection / design of the short-circuit tripmagnetic
Short-circuit protection / protection of the main circuit / at 500 VgG 32 A
Short-circuit protection / protection of the main circuit / at 690 VgG 25 A
Installation/ mounting/ dimensions / mounting positionany
Installation/ mounting/ dimensions / depth97 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / forwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / backwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / upwards50 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / downwards50 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / at the side0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / downwards30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / upwards30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / at the side9 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / downwards30 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / upwards30 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / at the side9 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / downwards30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / upwards30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / at the side9 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / downwards30 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / upwards30 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / at the side9 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / forwards0 mm
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / solid or stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Connections/ Terminals / connectable conductor cross-section for main contacts / solid or stranded0.75 ... 4 mm²
Connections/ Terminals / connectable conductor cross-section for main contacts / finely stranded with core end processing0.5 ... 2.5 mm²
Connections/ Terminals / connectable conductor cross-section for auxiliary contacts / solid or stranded0.5 ... 2.5 mm²
Connections/ Terminals / connectable conductor cross-section for auxiliary contacts / finely stranded with core end processing0.5 ... 2.5 mm²
Connections/ Terminals / type of connectable conductor cross-sections / for auxiliary contacts / solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for auxiliary contacts / finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Connections/ Terminals / tightening torque / for main contacts with screw-type terminals0.8 ... 1.2 N·m
Connections/ Terminals / tightening torque / for auxiliary contacts with screw-type terminals0.8 ... 1.2 N·m
Connections/ Terminals / design of screwdriver shaftDiameter 5 to 6 mm
Connections/ Terminals / size of the screwdriver tipPozidriv size 2
Display / display version for switching statusHandle
Сертификация1.98 kg
Сертификация0.134 kg
Сертификация72.7 kg
Сертификация-0.116 kg
Further information / last modified:5/5/2026