Автоматический выключатель защиты двигателя Siemens 3RV2023-4DA20, серия 3RV2. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.

  • Бренд: Siemens AG
  • Артикул (MPN): 3RV2023-4DA20
  • Серия: 3RV2 Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationcircuit breaker frame size S0 for motor protection, Class 10 thermal overload release 18…25 A short-circuit release 325 A spring-loaded terminal switching capacity 30 kA at 600 V according to UL/CSA
product brand nameSIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV2
General technical data / product function disconnector functionalityYes
General technical data / product extension auxiliary switchYes
General technical data / power loss [W] for rated value of the current / at AC in hot operating state10.5 W
General technical data / power loss [W] for rated value of the current / at AC in hot operating state per pole3.5 W
General technical data / type of calculation of power loss current-dependentquadratic
Напряжение питания690 V
Напряжение питания6 kV
Напряжение питания400 V
General technical data / protection class IP / on the frontIP20
General technical data / protection class IP / of the terminalIP20
General technical data / shock resistance according to IEC 60068-2-2725g / 11 ms
General technical data / mechanical service life (operating cycles) / of the main contacts typical100 000
General technical data / mechanical service life (operating cycles) / of auxiliary contacts typical100 000
General technical data / electrical endurance (operating cycles) typical100 000
General technical data / reference code according to IEC 81346-2Q
General technical data / continuous current rated value25 A
General technical data / Substance Prohibitance (day/month/year)10/01/2009
Масса0.393 kg
Ambient conditions / installation altitude at height above sea level maximum2 000 m
Рабочая температура-20 ... +60 °C
Ambient conditions / ambient temperature / during storage-50 ... +80 °C
Рабочая температура-50 ... +80 °C
Ambient conditions / temperature compensation-20 ... +60 °C
Ambient conditions / relative humidity during operation10 ... 95 %
Напряжение питания690 V
Напряжение питания20 ... 690 V
Напряжение питания690 V
Напряжение питания690 V
Main circuit / operating frequency rated value50 ... 60 Hz
Main circuit / operational current rated value25 A
Main circuit / operational current / at AC-3 at 400 V rated value25 A
Main circuit / operational current / at AC-3e at 400 V rated value25 A
Main circuit / operating power / at AC-3 / at 690 V rated value22 kW
Main circuit / operating power / at AC-3e / at 690 V rated value22 kW
Main circuit / operating frequency / at AC-3 maximum15 1/h
Main circuit / operating frequency / at AC-3e maximum15 1/h
Напряжение питанияAC/DC
Auxiliary circuit / number of NC contacts for auxiliary contacts0
Auxiliary circuit / number of NO contacts for auxiliary contacts0
Auxiliary circuit / number of CO contacts for auxiliary contacts0
Protective and monitoring functions / product function / ground fault detectionNo
Protective and monitoring functions / product function / phase failure detectionYes
Protective and monitoring functions / trip classCLASS 10
Protective and monitoring functions / design of the overload releasethermal
Protective and monitoring functions / protection function thermal overload protection (ANSI 49)Yes
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 690 V rated value4 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 690 V rated value2 kA
Protective and monitoring functions / response value current of instantaneous short-circuit trip unit325 A
UL/CSA ratings / full-load current (FLA) for 3-phase AC motor / at 480 V rated value25 A
UL/CSA ratings / full-load current (FLA) for 3-phase AC motor / at 600 V rated value25 A
UL/CSA ratings / yielded mechanical performance [hp] / for single-phase AC motor / at 110/120 V rated value2 hp
UL/CSA ratings / yielded mechanical performance [hp] / for single-phase AC motor / at 230 V rated value3 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 200/208 V rated value5 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 220/230 V rated value7.5 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 460/480 V rated value15 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 575/600 V rated value20 hp
UL/CSA ratings / UL File Number (CCN)E47705 (NLRV, NLRV7)
Short-circuit protection / protection of the main circuit / at 500 VgG 50 A
Short-circuit protection / protection of the main circuit / at 690 VgG 50 A
Installation/ mounting/ dimensions / mounting positionany
Installation/ mounting/ dimensions / depth97 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / forwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / backwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / upwards50 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / downwards50 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / at the side0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / at the side30 mm
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / solid or stranded2x (1 ... 10 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / finely stranded with core end processing2x (1 ... 6 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / finely stranded without core end processing2x (1 ... 6 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for AWG cables for main contacts2x (18 ... 8)
Connections/ Terminals / connectable conductor cross-section for main contacts / solid or stranded1 ... 10 mm²
Connections/ Terminals / connectable conductor cross-section for main contacts / finely stranded with core end processing1 ... 6 mm²
Safety related data / product function suitable for safety functionYes
Safety related data / suitability for use / safety-related switching onNo
Safety related data / suitability for use / safety-related switching OFFYes
Safety related data / service life maximum10 a
Safety related data / test wear-related service life necessaryYes
Safety related data / proportion of dangerous failures / with low demand rate according to SN 3192040 %
Safety related data / proportion of dangerous failures / with high demand rate according to SN 3192050 %
Display / display version for switching statusHandle
Сертификация2.68 kg
Сертификация0.143 kg
Сертификация72.7 kg
Сертификация-0.445 kg
Further information / last modified:5/5/2026
Получить предложение по этой позиции