Автоматические выключатели защиты электродвигателей
SI

Siemens AG 3RV2031-4XB10

Автоматический выключатель защиты двигателя Siemens 3RV2031-4XB10, серия 3RV2. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.

  • Бренд: Siemens AG
  • Артикул (MPN): 3RV2031-4XB10
  • Серия: 3RV2 Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationCircuit breaker size S2 for motor protection, Class 20 A-release 49...59 A N- release 845 A screw terminal Standard switching capacity product brand name SIRIUS product designation Circuit breaker design of the product For motor protection product type designation 3RV2 General technical data
product function disconnector functionalityYes
product extension auxiliary switchYes
power loss [W] for rated value of the current / at AC in hot operating state26 W
power loss [W] for rated value of the current / at AC in hot operating state per pole8.7 W
type of calculation of power loss current-dependentquadratic
Напряжение питания690 V
Напряжение питания6 kV
Напряжение питания400 V
protection class IP / on the frontIP20
protection class IP / of the terminalIP00
shock resistance according to IEC 60068-2-2725 g / 11 ms Sinus
mechanical service life (operating cycles) / of the main contacts typical20 000
mechanical service life (operating cycles) / of auxiliary contacts typical20 000
electrical endurance (operating cycles) typical20 000
reference code according to IEC 81346-2Q
continuous current rated value59 A
Substance Prohibitance (day/month/year)04/10/2015
SVHC substance nameLead CAS-No. 7439-92-1
Масса1.214 kg
Ambient conditions / installation altitude at height above sea level maximum2 000 m
Рабочая температура-20 ... +60 °C
Ambient conditions / ambient temperature / during storage-50 ... +80 °C
Рабочая температура-50 ... +80 °C
Ambient conditions / temperature compensation-20 ... +60 °C
Ambient conditions / relative humidity during operation10 ... 95 %
Напряжение питания690 V
Напряжение питания20 ... 690 V
Напряжение питания690 V
Напряжение питания690 V
Main circuit / operating frequency rated value50 ... 60 Hz
Main circuit / operational current rated value59 A
Main circuit / operational current / at AC-3 at 400 V rated value59 A
Main circuit / operational current / at AC-3e at 400 V rated value59 A
Main circuit / operating power / at AC-3 / at 230 V rated value15 kW
Main circuit / operating power / at AC-3 / at 400 V rated value30 kW
Main circuit / operating power / at AC-3 / at 500 V rated value37 kW
Main circuit / operating power / at AC-3 / at 690 V rated value55 kW
Main circuit / operating power / at AC-3e / at 230 V rated value15 kW
Main circuit / operating power / at AC-3e / at 400 V rated value30 kW
Main circuit / operating power / at AC-3e / at 500 V rated value37 kW
Main circuit / operating power / at AC-3e / at 690 V rated value55 kW
Main circuit / operating frequency / at AC-3 maximum15 1/h
Main circuit / operating frequency / at AC-3e maximum15 1/h
Напряжение питанияAC/DC
Auxiliary circuit / number of NC contacts for auxiliary contacts0
Auxiliary circuit / number of NO contacts for auxiliary contacts0
Auxiliary circuit / number of CO contacts for auxiliary contacts0
Protective and monitoring functions / product function / ground fault detectionNo
Protective and monitoring functions / product function / phase failure detectionYes
Protective and monitoring functions / trip classCLASS 20
Protective and monitoring functions / design of the overload releasethermal
Protective and monitoring functions / protection function thermal overload protection (ANSI 49)Yes
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 240 V rated value65 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 400 V rated value65 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 500 V rated value8 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 690 V rated value4 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 240 V rated value100 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 400 V rated value30 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 500 V rated value4 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 690 V rated value2 kA
Protective and monitoring functions / response value current of instantaneous short-circuit trip unit845 A
UL/CSA ratings / full-load current (FLA) for 3-phase AC motor / at 480 V rated value59 A
UL/CSA ratings / full-load current (FLA) for 3-phase AC motor / at 600 V rated value59 A
UL/CSA ratings / yielded mechanical performance [hp] / for single-phase AC motor / at 110/120 V rated value5 hp
UL/CSA ratings / yielded mechanical performance [hp] / for single-phase AC motor / at 230 V rated value10 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 220/230 V rated value20 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 460/480 V rated value40 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 575/600 V rated value50 hp
Short-circuit protection / protection of the main circuit / at 400 V160
Short-circuit protection / protection of the main circuit / at 500 V125
Short-circuit protection / protection of the main circuit / at 690 V100
Installation/ mounting/ dimensions / mounting positionany
Installation/ mounting/ dimensions / depth149 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / forwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / backwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / upwards50 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / downwards50 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / at the side0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / downwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / upwards50 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / at the side10 mm
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / solid or stranded2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / finely stranded with core end processing2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for AWG cables for main contacts2x (18 ... 2), 1x (18 ... 1)
Connections/ Terminals / connectable conductor cross-section for main contacts / solid or stranded1 ... 50 mm²
Connections/ Terminals / design of screwdriver shaftDiameter 5 to 6 mm
Connections/ Terminals / size of the screwdriver tipPozidriv size 2
Connections/ Terminals / design of the thread of the connection screw / for main contactsM6
Safety related data / product function suitable for safety functionYes
Safety related data / suitability for use / safety-related switching onNo
Safety related data / suitability for use / safety-related switching OFFYes
Safety related data / service life maximum10 a
Safety related data / test wear-related service life necessaryYes
Safety related data / proportion of dangerous failures / with low demand rate according to SN 3192040 %
Safety related data / proportion of dangerous failures / with high demand rate according to SN 3192050 %
Display / display version for switching statusHandle
Сертификация12.8 kg
Сертификация0.477 kg
Сертификация230 kg
Сертификация-3.4 kg
Further information / last modified:5/5/2026