Технические характеристики

Data sheet designationCircuit breaker size S3 for motor protection, CLASS 10 A-release 45...63 A N- release 819 A screw terminal Standard switching capacity
product brand nameSIRIUS
product designationCircuit breaker
design of the productFor motor protection
product type designation3RV2
General technical data / product function disconnector functionalityYes
General technical data / product extension auxiliary switchYes
General technical data / power loss [W] for rated value of the current / at AC in hot operating state34 W
General technical data / power loss [W] for rated value of the current / at AC in hot operating state per pole11.3 W
General technical data / type of calculation of power loss current-dependentquadratic
Напряжение питания1 000 V
Напряжение питания8 kV
Напряжение питания400 V
General technical data / protection class IP / on the frontIP20
General technical data / protection class IP / of the terminalIP00
General technical data / shock resistance according to IEC 60068-2-2725 g / 11 ms Sinus
General technical data / mechanical service life (operating cycles) / of the main contacts typical25 000
General technical data / mechanical service life (operating cycles) / of auxiliary contacts typical25 000
General technical data / electrical endurance (operating cycles) typical25 000
General technical data / reference code according to IEC 81346-2Q
General technical data / continuous current rated value63 A
General technical data / Substance Prohibitance (day/month/year)03/01/2017
General technical data / SVHC substance nameLead CAS-No. 7439-92-1
Масса2.163 kg
Ambient conditions / installation altitude at height above sea level maximum2 000 m
Рабочая температура-20 ... +60 °C
Ambient conditions / ambient temperature / during storage-50 ... +80 °C
Рабочая температура-50 ... +80 °C
Ambient conditions / temperature compensation-20 ... +60 °C
Ambient conditions / relative humidity during operation10 ... 95 %
Напряжение питания690 V
Напряжение питания20 ... 690 V
Напряжение питания690 V
Напряжение питания690 V
Main circuit / operating frequency rated value50 ... 60 Hz
Main circuit / operational current rated value63 A
Main circuit / operational current / at AC-3 at 400 V rated value63 A
Main circuit / operational current / at AC-3e at 400 V rated value63 A
Main circuit / operating power / at AC-3 / at 230 V rated value18.5 kW
Main circuit / operating power / at AC-3 / at 400 V rated value30 kW
Main circuit / operating power / at AC-3 / at 500 V rated value37 kW
Main circuit / operating power / at AC-3 / at 690 V rated value55 kW
Main circuit / operating power / at AC-3e / at 230 V rated value18.5 kW
Main circuit / operating power / at AC-3e / at 400 V rated value30 kW
Main circuit / operating power / at AC-3e / at 500 V rated value37 kW
Main circuit / operating power / at AC-3e / at 690 V rated value55 kW
Main circuit / operating frequency / at AC-3 maximum15 1/h
Main circuit / operating frequency / at AC-3e maximum15 1/h
Напряжение питанияAC/DC
Auxiliary circuit / number of NC contacts for auxiliary contacts0
Auxiliary circuit / number of NO contacts for auxiliary contacts0
Auxiliary circuit / number of CO contacts for auxiliary contacts0
Protective and monitoring functions / product function / ground fault detectionNo
Protective and monitoring functions / product function / phase failure detectionYes
Protective and monitoring functions / trip classCLASS 10
Protective and monitoring functions / design of the overload releasethermal
Protective and monitoring functions / protection function thermal overload protection (ANSI 49)Yes
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 240 V rated value100 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 400 V rated value65 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 500 V rated value12 kA
Protective and monitoring functions / maximum short-circuit current breaking capacity (Icu) / at AC at 690 V rated value6 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 240 V rated value100 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 400 V rated value30 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 500 V rated value6 kA
Protective and monitoring functions / operating short-circuit current breaking capacity (Ics) at AC / at 690 V rated value3 kA
Protective and monitoring functions / response value current of instantaneous short-circuit trip unit819 A
UL/CSA ratings / full-load current (FLA) for 3-phase AC motor / at 480 V rated value63 A
UL/CSA ratings / full-load current (FLA) for 3-phase AC motor / at 600 V rated value63 A
UL/CSA ratings / yielded mechanical performance [hp] / for single-phase AC motor / at 110/120 V rated value5 hp
UL/CSA ratings / yielded mechanical performance [hp] / for single-phase AC motor / at 230 V rated value15 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 200/208 V rated value20 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 220/230 V rated value25 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 460/480 V rated value50 hp
UL/CSA ratings / yielded mechanical performance [hp] / for 3-phase AC motor / at 575/600 V rated value60 hp
Short-circuit protection / product function short circuit protectionYes
Short-circuit protection / design of the short-circuit tripmagnetic
СертификацияDMT 02 ATEX F 001
Short-circuit protection / type of protection according to ATEX directive 2014/34/EUEx II (2) GD
Installation/ mounting/ dimensions / mounting positionany
Installation/ mounting/ dimensions / depth176 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / forwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / backwards0 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / upwards150 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / downwards150 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / at the side0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / upwards150 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / downwards150 mm
Installation/ mounting/ dimensions / required spacing / for live parts / forwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / backwards0 mm
Installation/ mounting/ dimensions / required spacing / for live parts / upwards150 mm
Installation/ mounting/ dimensions / required spacing / for live parts / downwards150 mm
Installation/ mounting/ dimensions / required spacing / for live parts / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / downwards70 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / upwards70 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 400 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / downwards70 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / upwards70 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 400 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / downwards110 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / upwards110 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 500 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / downwards110 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / upwards110 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 500 V / at the side10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / downwards150 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / upwards150 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts at 690 V / at the side30 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / downwards150 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / upwards150 mm
Installation/ mounting/ dimensions / required spacing / for live parts at 690 V / at the side30 mm
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / solid2x (2.5 ... 16 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / solid or stranded2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / finely stranded with core end processing2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for main contacts / finely stranded without core end processing2x (10 ... 35 mm²), 1x (10 ... 50 mm²)
Connections/ Terminals / connectable conductor cross-section for main contacts / finely stranded with core end processing2.5 ... 50 mm²
Connections/ Terminals / outer diameter of the usable ring cable lug maximum19 mm
Connections/ Terminals / tightening torque / for main contacts with screw-type terminals4.5 ... 6 N·m
Safety related data / product function suitable for safety functionYes
Safety related data / suitability for use / safety-related switching onNo
Safety related data / suitability for use / safety-related switching OFFYes
Safety related data / service life maximum10 a
Safety related data / test wear-related service life necessaryYes
Safety related data / proportion of dangerous failures / with low demand rate according to SN 3192040 %
Safety related data / proportion of dangerous failures / with high demand rate according to SN 3192050 %
Display / display version for switching statusHandle
Сертификация18.5 kg
Сертификация1.24 kg
Сертификация265 kg
Сертификация-1.5 kg