| Data sheet designation | SIRIUS soft starter 200-600 V 47 A, 24 V AC/DC spring-type terminals Analog output |
|---|---|
| product brand name | SIRIUS |
| product category | Hybrid switching devices |
| product designation | Soft starter |
| product type designation | 3RW52 |
| manufacturer's article number / of standard HMI module usable | 3RW5980-0HS00 |
| manufacturer's article number / of high feature HMI module usable | 3RW5980-0HF00 |
| manufacturer's article number / of communication module PROFINET standard usable | 3RW5980-0CS00 |
| manufacturer's article number / of communication module PROFIBUS usable | 3RW5980-0CP00 |
| manufacturer's article number / of communication module Modbus TCP usable | 3RW5980-0CT00 |
| manufacturer's article number / of communication module Modbus RTU usable | 3RW5980-0CR00 |
| manufacturer's article number / of communication module Ethernet/IP | 3RW5980-0CE00 |
| manufacturer's article number / of circuit breaker usable at 400 V | 3RV2032-4JA10; Type of coordination 1, Iq = 65 kA, CLASS 10 |
| manufacturer's article number / of circuit breaker usable at 500 V | 3RV2032-4JA10; Type of coordination 1, Iq = 10 kA, CLASS 10 |
| manufacturer's article number / of circuit breaker usable at 400 V at inside-delta circuit | 3RV2032-4RA10; Type of coordination 1, Iq = 65 kA, CLASS 10 |
| manufacturer's article number / of circuit breaker usable at 500 V at inside-delta circuit | 3RV2032-4RA10; Type of coordination 1, Iq = 10 kA, CLASS 10 |
| manufacturer's article number / of the gG fuse usable up to 690 V | 3NA3824-6; Type of coordination 1, Iq = 65 kA |
| manufacturer's article number / of the gG fuse usable at inside-delta circuit up to 500 V | 3NA3824-6; Type of coordination 1, Iq = 65 kA |
| manufacturer's article number / of full range R fuse link for semiconductor protection | 3NE1021-2; Type of coordination 2, Iq = 65 kA |
| Напряжение питания | 50 %; non-adjustable |
| General technical data / start-up ramp time of soft starter | 0 ... 20 s |
| General technical data / current limiting value [%] adjustable | 130 ... 700 % |
| Сертификация | Yes |
| Сертификация | Yes |
| Сертификация | Yes |
| General technical data / product component / HMI-High Feature | No |
| General technical data / product component / is supported HMI-Standard | Yes |
| General technical data / product component / is supported HMI-High Feature | Yes |
| General technical data / product feature integrated bypass contact system | Yes |
| General technical data / buffering time in the event of power failure / for main current circuit | 100 ms |
| General technical data / buffering time in the event of power failure / for control circuit | 100 ms |
| Напряжение питания | 600 V |
| General technical data / degree of pollution | 3, acc. to IEC 60947-4-2 |
| Напряжение питания | 6 kV |
| Напряжение питания | 1 800 V |
| General technical data / service factor | 1 |
| Напряжение питания | 6 kV |
| Напряжение питания | 600 V |
| General technical data / shock resistance | 15 g / 11 ms, from 12 g / 11 ms with potential contact lifting |
| General technical data / vibration resistance | 15 mm to 6 Hz; 2 g to 500 Hz |
| General technical data / utilization category according to IEC 60947-4-2 | AC 53a |
| General technical data / reference code according to IEC 81346-2 | Q |
| General technical data / product function / ramp-up (soft starting) | Yes |
| General technical data / product function / soft stopping | Yes |
| General technical data / product function / Soft Torque | Yes |
| General technical data / product function / adjustable current limitation | Yes |
| General technical data / product function / pump stop | Yes |
| General technical data / product function / intrinsic device protection | Yes |
| General technical data / product function / motor overload protection | Yes; Electronic motor overload protection |
| General technical data / product function / evaluation of thermistor motor protection | No |
| General technical data / product function / inside-delta circuit | Yes |
| General technical data / product function / auto-RESET | Yes |
| General technical data / product function / manual RESET | Yes |
| General technical data / product function / remote reset | Yes; By turning off the control supply voltage |
| General technical data / product function / communication function | Yes |
| General technical data / product function / operating measured value display | Yes; Only in conjunction with special accessories |
| General technical data / product function / error logbook | Yes; Only in conjunction with special accessories |
| General technical data / product function / via software parameterizable | No |
| General technical data / product function / via software configurable | Yes |
| General technical data / product function / PROFIenergy | Yes; in connection with the PROFINET Standard communication module |
| General technical data / product function / firmware update | Yes |
| General technical data / product function / removable terminal for control circuit | Yes |
| General technical data / product function / torque control | No |
| General technical data / product function / analog output | Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI) |
| Power Electronics / operational current / at 40 °C rated value | 47 A |
| Power Electronics / operational current / at 50 °C rated value | 41.6 A |
| Power Electronics / operational current / at 60 °C rated value | 36.2 A |
| Power Electronics / operational current at inside-delta circuit / at 40 °C rated value | 81.4 A |
| Power Electronics / operational current at inside-delta circuit / at 50 °C rated value | 72 A |
| Power Electronics / operational current at inside-delta circuit / at 60 °C rated value | 62.7 A |
| Напряжение питания | 200 ... 600 V |
| Напряжение питания | 200 ... 600 V |
| Напряжение питания | -15 % |
| Power Electronics / operating power for 3-phase motors / at 230 V at inside-delta circuit at 40 °C rated value | 22 kW |
| Power Electronics / operating power for 3-phase motors / at 400 V at 40 °C rated value | 22 kW |
| Power Electronics / operating power for 3-phase motors / at 400 V at inside-delta circuit at 40 °C rated value | 45 kW |
| Power Electronics / operating power for 3-phase motors / at 500 V at 40 °C rated value | 30 kW |
| Power Electronics / operating power for 3-phase motors / at 500 V at inside-delta circuit at 40 °C rated value | 45 kW |
| Power Electronics / Operating frequency 1 rated value | 50 Hz |
| Power Electronics / Operating frequency 2 rated value | 60 Hz |
| Power Electronics / relative negative tolerance of the operating frequency | -10 % |
| Power Electronics / relative positive tolerance of the operating frequency | 10 % |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 1 | 20 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 2 | 21.8 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 3 | 23.6 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 4 | 25.4 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 5 | 27.2 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 6 | 29 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 7 | 30.8 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 8 | 32.6 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 9 | 34.4 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 10 | 36.2 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 11 | 38 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 12 | 39.8 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 13 | 41.6 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 14 | 43.4 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 15 | 45.2 A |
| Power Electronics / adjustable motor current / at rotary coding switch on switch position 16 | 47 A |
| Power Electronics / adjustable motor current / minimum | 20 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch | 34.6 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #2 | 37.8 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #3 | 40.9 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #4 | 44 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #5 | 47.1 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #6 | 50.2 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #7 | 53.3 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #8 | 56.5 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #9 | 59.6 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #10 | 62.7 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #11 | 65.8 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #12 | 68.9 A |
| Power Electronics / adjustable motor current / for inside-delta circuit at rotary coding switch on switch #13 | 72.1 A |
| Power Electronics / adjustable motor current / at inside-delta circuit minimum | 34.6 A |
| Power Electronics / minimum load [%] | 15 %; Relative to smallest settable Ie |
| Power Electronics / power loss [W] for rated value of the current at AC / at 40 °C after startup | 26 W |
| Power Electronics / power loss [W] for rated value of the current at AC / at 50 °C after startup | 24 W |
| Power Electronics / power loss [W] for rated value of the current at AC / at 60 °C after startup | 23 W |
| Power Electronics / power loss [W] at AC at current limitation 350% / at 40 °C during startup | 606 W |
| Power Electronics / power loss [W] at AC at current limitation 350% / at 50 °C during startup | 522 W |
| Power Electronics / power loss [W] at AC at current limitation 350% / at 60 °C during startup | 438 W |
| Напряжение питания | AC/DC |
| Напряжение питания | 24 V |
| Inputs/ Outputs / number of digital outputs | 3 |
| Inputs/ Outputs / not parameterizable | 2 |
| Inputs/ Outputs / digital output version | 2 normally-open contacts (NO) / 1 changeover contact (CO) |
| Inputs/ Outputs / number of analog outputs | 1 |
| Inputs/ Outputs / switching capacity current of the relay outputs / at AC-15 at 250 V rated value | 3 A |
| Inputs/ Outputs / switching capacity current of the relay outputs / at DC-13 at 24 V rated value | 1 A |
| Installation/ mounting/ dimensions / width | 185 mm |
| Installation/ mounting/ dimensions / depth | 203 mm |
| Installation/ mounting/ dimensions / required spacing with side-by-side mounting / forwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing with side-by-side mounting / backwards | 0 mm |
| Installation/ mounting/ dimensions / required spacing with side-by-side mounting / upwards | 100 mm |
| Installation/ mounting/ dimensions / required spacing with side-by-side mounting / downwards | 75 mm |
| Installation/ mounting/ dimensions / required spacing with side-by-side mounting / at the side | 5 mm |
| Масса | 5.2 kg |
| Connections/ Terminals / type of electrical connection / for main current circuit | box terminal |
| Connections/ Terminals / contacts for box terminal / using the front clamping point finely stranded with core | 1x (2.5 ... 50 mm²) |
| Connections/ Terminals / contacts for box terminal / using the front clamping point stranded | 1x (10 ... 70 mm²) |
| Connections/ Terminals / contacts for box terminal / using the back clamping point solid | 1x (2.5 ... 16 mm²) |
| Connections/ Terminals / contacts for box terminal / r box terminal using the back clamping point | 1x (10 ... 2/0) |
| Connections/ Terminals / contacts for box terminal / using both clamping points solid | 2x (2.5 ... 16 mm²) |
| Connections/ Terminals / contacts for box terminal / using both clamping points finely stranded with core end | 2x (2.5 ... 35 mm²) |
| Connections/ Terminals / contacts for box terminal / using both clamping points stranded | 2x (6 ... 16 mm²), 2x (10 ... 50 mm²) |
| Connections/ Terminals / contacts for box terminal / using the back clamping point finely stranded with core | 1x (2.5 ... 50 mm²) |
| Connections/ Terminals / contacts for box terminal / using the back clamping point stranded | 1x (10 ... 70 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / for control circuit solid | 2x (0.25 ... 1.5 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / for control circuit finely stranded with core end processing | 2x (0.25 ... 1.5 mm²) |
| Connections/ Terminals / wire length / at the digital inputs at AC maximum | 100 m |
| Connections/ Terminals / wire length / at the digital inputs at DC maximum | 1 000 m |
| Рабочая температура | -25 ... +60 °C; Please observe derating at temperatures of 40 °C or above |
| Ambient conditions / ambient temperature / during storage and transport | -40 ... +80 °C |
| Electromagnetic compatibility / EMC emitted interference | acc. to IEC 60947-4-2: Class A |
| Communication/ Protocol / communication module is supported / PROFINET standard | Yes |
| Communication/ Protocol / communication module is supported / EtherNet/IP | Yes |
| Communication/ Protocol / communication module is supported / Modbus RTU | Yes |
| Communication/ Protocol / communication module is supported / Modbus TCP | Yes |
| Communication/ Protocol / communication module is supported / PROFIBUS | Yes |
| UL/CSA ratings / manufacturer's article number / of circuit breaker usable for Standard Faults / at 460/480 V according to UL | Siemens type: 3RV2742, max. 70 A or 3VA51, max. 90 A; Iq = 5 kA |
| UL/CSA ratings / manufacturer's article number / of circuit breaker usable for Standard Faults / 60/480 V according to UL | Siemens type: 3VA51, max. 60 A; Iq max = 65 kA |
| UL/CSA ratings / manufacturer's article number / of circuit breaker usable for Standard Faults / at 460/480 V at inside-delta circuit according to UL | Siemens type: 3VA51, max. 90 A; Iq = 5 kA |
| UL/CSA ratings / manufacturer's article number / of circuit breaker usable for Standard Faults / 60/480 V at inside-delta circuit according to UL | Siemens type: 3VA51, max. 60 A; Iq max = 65 kA |
| UL/CSA ratings / manufacturer's article number / of circuit breaker usable for Standard Faults / at 575/600 V according to UL | Siemens type: 3RV2742, max. 70 A or 3VA51, max. 90 A; Iq = 5 kA |
| UL/CSA ratings / manufacturer's article number / of circuit breaker usable for Standard Faults / at 575/600 V at inside-delta circuit according to UL | Siemens type: 3VA51, max. 90 A; Iq = 5 kA |
| UL/CSA ratings / manufacturer's article number / of the fuse / usable for Standard Faults up to 575/600 V | Type: Class RK5 / K5, max. 175 A; Iq = 5 kA |
| UL/CSA ratings / manufacturer's article number / of the fuse / usable for High Faults up to 575/600 V according to | Type: Class J / L, max. 175 A; Iq = 100 kA |
| UL/CSA ratings / manufacturer's article number / of the fuse / usable for Standard Faults at inside-delta circuit up | Type: Class RK5 / K5, max. 175 A; Iq = 5 kA |
| UL/CSA ratings / operating power [hp] for 3-phase motors / at 220/230 V at 50 °C rated value | 10 hp |
| UL/CSA ratings / operating power [hp] for 3-phase motors / at 460/480 V at 50 °C rated value | 30 hp |
| UL/CSA ratings / operating power [hp] for 3-phase motors / at 575/600 V at 50 °C rated value | 40 hp |
| UL/CSA ratings / operating power [hp] for 3-phase motors / at 200/208 V at inside-delta circuit at 50 °C rated value | 20 hp |
| UL/CSA ratings / operating power [hp] for 3-phase motors / at 220/230 V at inside-delta circuit at 50 °C rated value | 25 hp |
| UL/CSA ratings / operating power [hp] for 3-phase motors / at 460/480 V at inside-delta circuit at 50 °C rated value | 50 hp |
| Сертификация | 67.7 kg |
| Сертификация | 1.84 kg |
| Сертификация | 242 kg |
| Сертификация | -15.7 kg |