Технические характеристики

Data sheet designationSIMATIC HMI KP400 Comfort, Comfort Panel, key operation, 4" widescreen TFT display, 16 million colors, PROFINET interface, MPI/PROFIBUS DP interface, 4 MB configuration memory, Windows CE 6.0, configurable from WinCC Comfort V11 General information Product type designation KP400 Comfort Display Design of display TFT Screen diagonal 4.3 in
Display width95 mm
Display height53.8 mm
Number of colors16 777 216
Resolution (pixels) / Horizontal image resolution480 pixel
Resolution (pixels) / Vertical image resolution272 pixel
Backlighting / MTBF backlighting (at 25 °C)80 000 h
Backlighting / Backlight dimmableYes; 0-100 %
Control elements / Keyboard / Function keys / Number of function keys8
Control elements / Keyboard / Function keys / Number of function keys with LEDs8
Control elements / Keyboard / Keys with LEDYes
Control elements / Keyboard / System keysYes
Control elements / Keyboard / Numeric keyboardYes
Control elements / Keyboard / alphanumeric keyboardYes; similar to mobile phone
Control elements / Touch operation / Design as touch screenNo; without
Control elements / Expansions for operator control of the process / DP direct LEDs (LEDs as S7 output I/O) / F1...Fx8
Control elements / Expansions for operator control of the process / Direct keys (keys as S7 input I/O) / F1...Fx8
Control elements / Expansions for operator control of the process / Direct keys (touch buttons as S7 input I/O)0
Installation type/mounting / Mounting positionvertical
Installation type/mounting / Wall mounting/direct mountingNo
Installation type/mounting / Mounting in portrait format possibleNo
Напряжение питания24 V
Напряжение питания19.2 V
Напряжение питания28.8 V
Input current / Current consumption (rated value)0.13 A
Input current / Starting current inrush I²t0.5 A²·s
Power / Active power input, typ.3.1 W
Processor / Processor typeARM
Storage / FlashYes
Storage / Memory available for user data4 Mbyte
Type of output / Info LEDYes
Type of output / Power LEDNo
Type of output / Error LEDNo
Type of output / Acoustics / BuzzerYes
Type of output / Acoustics / SpeakerNo
Time of day / Clock / Hardware clock (real-time)Yes
Time of day / Clock / Software clockYes
Time of day / Clock / retentiveYes; Back-up duration typically 6 weeks
Time of day / Clock / synchronizableYes
Interfaces / Number of industrial Ethernet interfaces1
Interfaces / Number of RS 485 interfaces1; RS 422 / 485 combined
Interfaces / Number of RS 422 interfaces1
Interfaces / Number of RS 232 interfaces0
Interfaces / Number of USB interfaces1; USB 2.0
Interfaces / USB Mini B1; 5-pole
Interfaces / Number of 20 mA interfaces (TTY)0
Interfaces / Number of parallel interfaces0
Interfaces / Number of SD card slots2
Interfaces / With software interfacesNo
Interfaces / Industrial Ethernet / Industrial Ethernet status LED2
Interfaces / Industrial Ethernet / Number of ports of the integrated switch1; No switch integrated
Protocols / PROFINETYes
Protocols / Supports protocol for PROFINET IOYes
Protocols / PROFIBUSYes
Protocols / EtherNet/IPYes
Protocols / Protocols (Ethernet) / TCP/IPYes
Protocols / Protocols (Ethernet) / DHCPYes
Protocols / Protocols (Ethernet) / SNMPYes
Protocols / Protocols (Ethernet) / LLDPYes
Protocols / WEB characteristics / HTTPYes
Protocols / WEB characteristics / HTTPSNo
Protocols / WEB characteristics / HTMLYes
Protocols / WEB characteristics / Active XNo
Protocols / MODBUSYes
Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readableYes; S7 controller
Degree and class of protection / IP (at the front)IP65
Degree and class of protection / IP (rear)IP20
Degree and class of protection / NEMA (front) / Enclosure Type 4 at the frontYes
Degree and class of protection / NEMA (front) / Enclosure Type 4x at the frontYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияNo
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
Ambient conditions / Operation (vertical installation) / For vertical installation, max.50 °C
Ambient conditions / Operation (max. tilt angle) / At maximum tilt angle, min.0 °C
Ambient conditions / Operation (max. tilt angle) / At maximum tilt angle, max.40 °C
Ambient conditions / Operation (vertical installation, portrait format) / For vertical installation, min.0 °C
Ambient conditions / Operation (vertical installation, portrait format) / For vertical installation, max.40 °C
Ambient conditions / Operation (max. tilt angle, portrait format) / At maximum tilt angle, min.0 °C
Ambient conditions / Operation (max. tilt angle, portrait format) / At maximum tilt angle, max.35 °C
Ambient conditions / Ambient temperature during storage/transportation / min.-20 °C
Ambient conditions / Ambient temperature during storage/transportation / max.60 °C
Ambient conditions / Relative humidity / Operation, max.90 %; no condensation
Configuration / Alarm system (incl. buffer and acknowledgment)Yes
Configuration / Process value display (output)Yes
Configuration / Process value default (input) possibleYes
Configuration / Recipe managementYes
Configuration / Configuration software / STEP 7 Basic (TIA Portal)No
Configuration / Configuration software / STEP 7 Professional (TIA Portal)No
Configuration / Configuration software / WinCC flexible CompactNo
Configuration / Configuration software / WinCC flexible StandardNo
Configuration / Configuration software / WinCC flexible AdvancedNo
Configuration / Configuration software / WinCC Basic (TIA Portal)No
Configuration / Configuration software / WinCC Comfort (TIA Portal)Yes; from V11
Configuration / Configuration software / WinCC Advanced (TIA Portal)Yes; from V11
Configuration / Configuration software / WinCC Professional (TIA Portal)Yes; from V11
Languages / Online languages / Number of online/runtime languages32
Languages / Project languages / Languages per project32
Functionality under WinCC (TIA Portal) / LibrariesYes
Functionality under WinCC (TIA Portal) / Applications/options / Web browserYes
Functionality under WinCC (TIA Portal) / Applications/options / Pocket WordYes
Functionality under WinCC (TIA Portal) / Applications/options / Pocket ExcelYes
Functionality under WinCC (TIA Portal) / Applications/options / PDF ViewerYes
Functionality under WinCC (TIA Portal) / Applications/options / Media PlayerYes
Functionality under WinCC (TIA Portal) / Applications/options / SIMATIC WinCC Sm@rtServerYes
Functionality under WinCC (TIA Portal) / Applications/options / SIMATIC WinCC AuditYes
Functionality under WinCC (TIA Portal) / Number of Visual Basic ScriptsYes
Functionality under WinCC (TIA Portal) / Task planner / time-controlledYes
Functionality under WinCC (TIA Portal) / Task planner / task-controlledYes
Functionality under WinCC (TIA Portal) / Help system / Number of characters per info text70
Functionality under WinCC (TIA Portal) / Message system / Number of alarm classes32
Functionality under WinCC (TIA Portal) / Message system / Bit messagesYes
Functionality under WinCC (TIA Portal) / Message system / Number of bit messages2 000
Functionality under WinCC (TIA Portal) / Message system / Analog messagesYes
Functionality under WinCC (TIA Portal) / Message system / Number of analog messages50
Functionality under WinCC (TIA Portal) / Message system / S7 alarm number procedureYes
Functionality under WinCC (TIA Portal) / Message system / System messages HMIYes
Functionality under WinCC (TIA Portal) / Message system / System event, more (SIMATIC S7, SINUMERIK,Yes
Functionality under WinCC (TIA Portal) / Message system / Number of characters per message80
Functionality under WinCC (TIA Portal) / Message system / Number of process values per message8
Functionality under WinCC (TIA Portal) / Message system / Acknowledgment groupsYes
Functionality under WinCC (TIA Portal) / Message system / Message indicatorYes
Functionality under WinCC (TIA Portal) / Message system / Message buffer / Number of entries256
Functionality under WinCC (TIA Portal) / Message system / Message buffer / Circulating bufferYes
Functionality under WinCC (TIA Portal) / Message system / Message buffer / retentiveYes
Functionality under WinCC (TIA Portal) / Message system / Message buffer / maintenance-freeYes
Functionality under WinCC (TIA Portal) / Recipe management / Number of recipes100
Functionality under WinCC (TIA Portal) / Recipe management / Data records per recipe200
Functionality under WinCC (TIA Portal) / Recipe management / Entries per data record200
Functionality under WinCC (TIA Portal) / Recipe management / Size of internal recipe memory512 kbyte
Functionality under WinCC (TIA Portal) / Recipe management / Recipe memory expandableYes
Functionality under WinCC (TIA Portal) / Variables / Number of variables per device1 024
Functionality under WinCC (TIA Portal) / Variables / Number of variables per screen50
Functionality under WinCC (TIA Portal) / Variables / Limit valuesYes
Functionality under WinCC (TIA Portal) / Variables / MultiplexingYes
Functionality under WinCC (TIA Portal) / Variables / StructuresYes
Functionality under WinCC (TIA Portal) / Variables / ArraysYes
Functionality under WinCC (TIA Portal) / Images / Number of configurable images500
Functionality under WinCC (TIA Portal) / Images / Permanent window/defaultYes
Functionality under WinCC (TIA Portal) / Images / Global imageYes
Functionality under WinCC (TIA Portal) / Images / Pop-up imagesYes
Functionality under WinCC (TIA Portal) / Images / Slide-in imagesYes
Functionality under WinCC (TIA Portal) / Images / Image selection by PLCYes
Functionality under WinCC (TIA Portal) / Images / Image number in the PLCYes
Functionality under WinCC (TIA Portal) / Image objects / Number of objects per image50
Functionality under WinCC (TIA Portal) / Image objects / Text fieldsYes
Functionality under WinCC (TIA Portal) / Image objects / I/O fieldsYes
Functionality under WinCC (TIA Portal) / Image objects / Graphic I/O fields (graphics list)Yes
Functionality under WinCC (TIA Portal) / Image objects / Symbolic I/O fields (text list)Yes
Functionality under WinCC (TIA Portal) / Image objects / Date/time fieldsYes
Functionality under WinCC (TIA Portal) / Image objects / SwitchesYes
Functionality under WinCC (TIA Portal) / Image objects / ButtonsYes
Functionality under WinCC (TIA Portal) / Image objects / Graphic displayYes
Functionality under WinCC (TIA Portal) / Image objects / IconsYes
Functionality under WinCC (TIA Portal) / Image objects / Geometric objectsYes
Functionality under WinCC (TIA Portal) / Complex image objects / Number of complex objects per screen5
Functionality under WinCC (TIA Portal) / Complex image objects / Alarm viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Trend viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / User viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Status/controlYes
Functionality under WinCC (TIA Portal) / Complex image objects / Sm@rtClient viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Recipe viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / f(x) trend viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / System diagnostics viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Media PlayerYes
Functionality under WinCC (TIA Portal) / Complex image objects / HTML browserNo
Functionality under WinCC (TIA Portal) / Complex image objects / PDF displayYes
Functionality under WinCC (TIA Portal) / Complex image objects / IP camera displayYes
Functionality under WinCC (TIA Portal) / Complex image objects / Bar graphsYes
Functionality under WinCC (TIA Portal) / Complex image objects / SlidersYes
Functionality under WinCC (TIA Portal) / Complex image objects / Pointer instrumentsYes
Functionality under WinCC (TIA Portal) / Complex image objects / Analog/digital clockYes
Functionality under WinCC (TIA Portal) / Lists / Number of text lists per project300
Functionality under WinCC (TIA Portal) / Lists / Number of entries per text list30
Functionality under WinCC (TIA Portal) / Lists / Number of graphics lists per project100
Functionality under WinCC (TIA Portal) / Lists / Number of entries per graphics list30
Functionality under WinCC (TIA Portal) / Archiving / Number of archives per device10
Functionality under WinCC (TIA Portal) / Archiving / Number of entries per archive10 000
Functionality under WinCC (TIA Portal) / Archiving / Message archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Process value archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Archiving methods / Sequential archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Archiving methods / Short-term archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Memory location / Memory cardYes
Functionality under WinCC (TIA Portal) / Archiving / Memory location / USB memoryYes
Functionality under WinCC (TIA Portal) / Archiving / Memory location / EthernetYes
Functionality under WinCC (TIA Portal) / Security / Number of user groups50
Functionality under WinCC (TIA Portal) / Security / Number of user rights32
Functionality under WinCC (TIA Portal) / Security / Number of users50
Functionality under WinCC (TIA Portal) / Security / Password export/importYes
Functionality under WinCC (TIA Portal) / Security / SIMATIC LogonYes
Functionality under WinCC (TIA Portal) / Logging through printer / AlarmsYes
Functionality under WinCC (TIA Portal) / Logging through printer / Report (shift log)Yes
Functionality under WinCC (TIA Portal) / Logging through printer / HardcopyYes
Functionality under WinCC (TIA Portal) / Logging through printer / Electronic print to fileYes; PDF, HTML
Functionality under WinCC (TIA Portal) / Character sets / Keyboard fonts / US EnglishYes
Functionality under WinCC (TIA Portal) / Transfer (upload/download) / MPI/PROFIBUS DPYes
Functionality under WinCC (TIA Portal) / Transfer (upload/download) / EthernetYes
Functionality under WinCC (TIA Portal) / Transfer (upload/download) / using external storage mediumYes
Functionality under WinCC (TIA Portal) / Process coupling / S7-1200Yes
Functionality under WinCC (TIA Portal) / Process coupling / S7-1500Yes
Functionality under WinCC (TIA Portal) / Process coupling / S7-200Yes
Functionality under WinCC (TIA Portal) / Process coupling / S7-300/400Yes
Functionality under WinCC (TIA Portal) / Process coupling / LOGO!Yes
Functionality under WinCC (TIA Portal) / Process coupling / WinACYes
Functionality under WinCC (TIA Portal) / Process coupling / SINUMERIKYes; with SINUMERIK option package
Functionality under WinCC (TIA Portal) / Process coupling / SIMOTIONYes
Functionality under WinCC (TIA Portal) / Process coupling / Allen Bradley (EtherNet/IP)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Allen Bradley (DF1)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Mitsubishi (MC TCP/IP)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Mitsubishi (FX)Yes
Functionality under WinCC (TIA Portal) / Process coupling / OMRON (FINS TCP)No
Functionality under WinCC (TIA Portal) / Process coupling / OMRON (Host Link)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Modicon (Modbus TCP/IP)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Modicon (Modbus RTU)Yes
Functionality under WinCC (TIA Portal) / Process coupling / OPC UA ClientYes
Functionality under WinCC (TIA Portal) / Process coupling / OPC UA ServerYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / Backup/Restore manuallyYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / Backup/Restore automaticallyYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / SimulationYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / Device switchoverYes
Peripherals/Options / PrinterYes
Peripherals/Options / SIMATIC HMI MM memory card: Multi Media CardYes; Up to 128 MB
Peripherals/Options / SIMATIC HMI SD memory card: Secure Digital memory cardYes; Up to 2 GB
Peripherals/Options / SIMATIC HMI CF memory card Compact Flash CardNo
Peripherals/Options / USB memoryYes
Peripherals/Options / SIMATIC IPC USB Flashdrive (USB stick)Yes; Up to 16 GB
Peripherals/Options / SIMATIC HMI USB stickYes; Up to 8 GB
Peripherals/Options / Network cameraYes
МатериалYes
МатериалNo
МатериалNo
Dimensions / Width of the housing front152 mm
Dimensions / Height of housing front188 mm
Dimensions / Mounting cutout, width136 mm
Dimensions / Mounting cutout, height172 mm
Dimensions / mounting depth48 mm
Масса0.8 kg
Сертификация4/4/2025
Получить предложение по этой позиции