  • Артикул (MPN): 6AV2124-2DC01-0AX0
  • Серия: HMI-Comfort Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationSIMATIC HMI KTP400 Comfort, Comfort Panel, key/touch operation, 4" widescreen TFT display, 16 million colors, PROFINET interface, MPI/PROFIBUS DP interface, 4 MB configuration memory, Windows CE 6.0, configurable from WinCC Comfort V11
General information / Product type designationKTP400 Comfort
Display / Design of displayTFT
Display / Screen diagonal4.3 in
Display / Display width95 mm
Display / Display height53.8 mm
Display / Number of colors16 777 216
Display / Resolution (pixels) / Horizontal image resolution480 pixel
Display / Resolution (pixels) / Vertical image resolution272 pixel
Display / Backlighting / MTBF backlighting (at 25 °C)80 000 h
Display / Backlighting / Backlight dimmableYes; 0-100 %
Control elements / Keyboard / Function keys / Number of function keys4
Control elements / Keyboard / Function keys / Number of function keys with LEDs4
Control elements / Keyboard / Keys with LEDYes
Control elements / Keyboard / System keysNo
Control elements / Keyboard / Numeric keyboardYes; Onscreen keyboard
Control elements / Keyboard / alphanumeric keyboardYes; Onscreen keyboard
Control elements / Touch operation / Design as touch screenYes; Analog-resistive
Control elements / Expansions for operator control of the process / DP direct LEDs (LEDs as S7 output I/O) / F1...Fx4
Control elements / Expansions for operator control of the process / Direct keys (keys as S7 input I/O) / F1...Fx4
Control elements / Expansions for operator control of the process / Direct keys (touch buttons as S7 input I/O)32
Installation type/mounting / Mounting positionvertical
Installation type/mounting / Wall mounting/direct mountingNo
Installation type/mounting / Mounting in portrait format possibleYes
Напряжение питания24 V
Напряжение питания19.2 V
Напряжение питания28.8 V
Input current / Current consumption (rated value)0.13 A
Input current / Starting current inrush I²t0.5 A²·s
Power / Active power input, typ.3.1 W
Processor / Processor typeARM
Storage / FlashYes
Storage / Memory available for user data4 Mbyte
Type of output / Info LEDNo
Type of output / Power LEDNo
Type of output / Error LEDNo
Type of output / Acoustics / BuzzerYes
Type of output / Acoustics / SpeakerNo
Time of day / Clock / Hardware clock (real-time)Yes
Time of day / Clock / Software clockYes
Time of day / Clock / retentiveYes; Back-up duration typically 6 weeks
Time of day / Clock / synchronizableYes
Interfaces / Number of industrial Ethernet interfaces1
Interfaces / Number of RS 485 interfaces1; RS 422 / 485 combined
Interfaces / Number of RS 422 interfaces1
Interfaces / Number of RS 232 interfaces0
Interfaces / Number of USB interfaces1; USB 2.0
Interfaces / USB Mini B1; 5-pole
Interfaces / Number of 20 mA interfaces (TTY)0
Interfaces / Number of parallel interfaces0
Interfaces / Number of SD card slots2
Interfaces / With software interfacesNo
Interfaces / Industrial Ethernet / Industrial Ethernet status LED2
Interfaces / Industrial Ethernet / Number of ports of the integrated switch1; No switch integrated
Protocols / PROFINETYes
Protocols / Supports protocol for PROFINET IOYes
Protocols / PROFIBUSYes
Protocols / EtherNet/IPYes
Protocols / Protocols (Ethernet) / TCP/IPYes
Protocols / Protocols (Ethernet) / DHCPYes
Protocols / Protocols (Ethernet) / SNMPYes
Protocols / Protocols (Ethernet) / LLDPYes
Protocols / WEB characteristics / HTTPYes
Protocols / WEB characteristics / HTTPSNo
Protocols / WEB characteristics / HTMLYes
Protocols / WEB characteristics / Active XNo
Protocols / Further protocols / MODBUSYes
Interrupts/diagnostics/status information / Diagnoses / Diagnostic information readableYes; S7 controller
Degree and class of protection / IP (at the front)IP65
Degree and class of protection / IP (rear)IP20
Degree and class of protection / NEMA (front) / Enclosure Type 4 at the frontYes
Degree and class of protection / NEMA (front) / Enclosure Type 4x at the frontYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияNo
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
СертификацияYes
Ambient conditions / Operation (vertical installation) / For vertical installation, max.50 °C
Ambient conditions / Operation (max. tilt angle) / At maximum tilt angle, min.0 °C
Ambient conditions / Operation (max. tilt angle) / At maximum tilt angle, max.40 °C
Ambient conditions / Operation (vertical installation, portrait format) / For vertical installation, min.0 °C
Ambient conditions / Operation (vertical installation, portrait format) / For vertical installation, max.40 °C
Ambient conditions / Operation (max. tilt angle, portrait format) / At maximum tilt angle, max.35 °C
Ambient conditions / Ambient temperature during storage/transportation / min.-20 °C
Ambient conditions / Ambient temperature during storage/transportation / max.60 °C
Ambient conditions / Relative humidity / Operation, max.90 %; no condensation
Operating systems / proprietaryNo
Operating systems / pre-installed operating system / Windows CEYes
Configuration / Message indicatorYes
Configuration / Alarm system (incl. buffer and acknowledgment)Yes
Configuration / Process value display (output)Yes
Configuration / Process value default (input) possibleYes
Configuration / Recipe managementYes
Configuration / Configuration software / STEP 7 Basic (TIA Portal)No
Configuration / Configuration software / STEP 7 Professional (TIA Portal)No
Configuration / Configuration software / WinCC flexible CompactNo
Configuration / Configuration software / WinCC flexible StandardNo
Configuration / Configuration software / WinCC flexible AdvancedNo
Configuration / Configuration software / WinCC Basic (TIA Portal)No
Configuration / Configuration software / WinCC Comfort (TIA Portal)Yes; from V11
Configuration / Configuration software / WinCC Advanced (TIA Portal)Yes; from V11
Configuration / Configuration software / WinCC Professional (TIA Portal)Yes; from V11
Languages / Online languages / Number of online/runtime languages32
Languages / Project languages / Languages per project32
Functionality under WinCC (TIA Portal) / LibrariesYes
Functionality under WinCC (TIA Portal) / Applications/options / Web browserYes
Functionality under WinCC (TIA Portal) / Applications/options / Pocket WordYes
Functionality under WinCC (TIA Portal) / Applications/options / Pocket ExcelYes
Functionality under WinCC (TIA Portal) / Applications/options / PDF ViewerYes
Functionality under WinCC (TIA Portal) / Applications/options / Media PlayerYes
Functionality under WinCC (TIA Portal) / Applications/options / SIMATIC WinCC Sm@rtServerYes
Functionality under WinCC (TIA Portal) / Applications/options / SIMATIC WinCC AuditYes
Functionality under WinCC (TIA Portal) / Number of Visual Basic ScriptsYes
Functionality under WinCC (TIA Portal) / Task planner / time-controlledYes
Functionality under WinCC (TIA Portal) / Task planner / task-controlledYes
Functionality under WinCC (TIA Portal) / Help system / Number of characters per info text70
Functionality under WinCC (TIA Portal) / Message system / Number of alarm classes32
Functionality under WinCC (TIA Portal) / Message system / Bit messagesYes
Functionality under WinCC (TIA Portal) / Message system / Number of bit messages2 000
Functionality under WinCC (TIA Portal) / Message system / Analog messagesYes
Functionality under WinCC (TIA Portal) / Message system / Number of analog messages50
Functionality under WinCC (TIA Portal) / Message system / S7 alarm number procedureYes
Functionality under WinCC (TIA Portal) / Message system / System messages HMIYes
Functionality under WinCC (TIA Portal) / Message system / System event, more (SIMATIC S7, SINUMERIK,Yes
Functionality under WinCC (TIA Portal) / Message system / Number of characters per message80
Functionality under WinCC (TIA Portal) / Message system / Number of process values per message8
Functionality under WinCC (TIA Portal) / Message system / Acknowledgment groupsYes
Functionality under WinCC (TIA Portal) / Message system / Message indicatorYes
Functionality under WinCC (TIA Portal) / Message system / Message buffer / Number of entries256
Functionality under WinCC (TIA Portal) / Message system / Message buffer / Circulating bufferYes
Functionality under WinCC (TIA Portal) / Message system / Message buffer / retentiveYes
Functionality under WinCC (TIA Portal) / Message system / Message buffer / maintenance-freeYes
Functionality under WinCC (TIA Portal) / Recipe management / Number of recipes100
Functionality under WinCC (TIA Portal) / Recipe management / Data records per recipe200
Functionality under WinCC (TIA Portal) / Recipe management / Entries per data record200
Functionality under WinCC (TIA Portal) / Recipe management / Size of internal recipe memory512 kbyte
Functionality under WinCC (TIA Portal) / Recipe management / Recipe memory expandableYes
Functionality under WinCC (TIA Portal) / Variables / Number of variables per device1 024
Functionality under WinCC (TIA Portal) / Variables / Number of variables per screen50
Functionality under WinCC (TIA Portal) / Variables / Limit valuesYes
Functionality under WinCC (TIA Portal) / Variables / MultiplexingYes
Functionality under WinCC (TIA Portal) / Variables / StructuresYes
Functionality under WinCC (TIA Portal) / Variables / ArraysYes
Functionality under WinCC (TIA Portal) / Images / Number of configurable images500
Functionality under WinCC (TIA Portal) / Images / Permanent window/defaultYes
Functionality under WinCC (TIA Portal) / Images / Global imageYes
Functionality under WinCC (TIA Portal) / Images / Pop-up imagesYes
Functionality under WinCC (TIA Portal) / Images / Slide-in imagesYes
Functionality under WinCC (TIA Portal) / Images / Image selection by PLCYes
Functionality under WinCC (TIA Portal) / Images / Image number in the PLCYes
Functionality under WinCC (TIA Portal) / Image objects / Number of objects per image50
Functionality under WinCC (TIA Portal) / Image objects / Text fieldsYes
Functionality under WinCC (TIA Portal) / Image objects / I/O fieldsYes
Functionality under WinCC (TIA Portal) / Image objects / Graphic I/O fields (graphics list)Yes
Functionality under WinCC (TIA Portal) / Image objects / Symbolic I/O fields (text list)Yes
Functionality under WinCC (TIA Portal) / Image objects / Date/time fieldsYes
Functionality under WinCC (TIA Portal) / Image objects / SwitchesYes
Functionality under WinCC (TIA Portal) / Image objects / ButtonsYes
Functionality under WinCC (TIA Portal) / Image objects / Graphic displayYes
Functionality under WinCC (TIA Portal) / Image objects / IconsYes
Functionality under WinCC (TIA Portal) / Image objects / Geometric objectsYes
Functionality under WinCC (TIA Portal) / Complex image objects / Number of complex objects per screen5
Functionality under WinCC (TIA Portal) / Complex image objects / Alarm viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Trend viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / User viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Status/controlYes
Functionality under WinCC (TIA Portal) / Complex image objects / Sm@rtClient viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Recipe viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / f(x) trend viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / System diagnostics viewYes
Functionality under WinCC (TIA Portal) / Complex image objects / Media PlayerYes
Functionality under WinCC (TIA Portal) / Complex image objects / HTML browserNo
Functionality under WinCC (TIA Portal) / Complex image objects / PDF displayYes
Functionality under WinCC (TIA Portal) / Complex image objects / IP camera displayYes
Functionality under WinCC (TIA Portal) / Complex image objects / Bar graphsYes
Functionality under WinCC (TIA Portal) / Complex image objects / SlidersYes
Functionality under WinCC (TIA Portal) / Complex image objects / Pointer instrumentsYes
Functionality under WinCC (TIA Portal) / Complex image objects / Analog/digital clockYes
Functionality under WinCC (TIA Portal) / Lists / Number of text lists per project300
Functionality under WinCC (TIA Portal) / Lists / Number of entries per text list30
Functionality under WinCC (TIA Portal) / Lists / Number of graphics lists per project100
Functionality under WinCC (TIA Portal) / Lists / Number of entries per graphics list30
Functionality under WinCC (TIA Portal) / Archiving / Number of archives per device10
Functionality under WinCC (TIA Portal) / Archiving / Number of entries per archive10 000
Functionality under WinCC (TIA Portal) / Archiving / Message archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Process value archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Archiving methods / Sequential archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Archiving methods / Short-term archiveYes
Functionality under WinCC (TIA Portal) / Archiving / Memory location / Memory cardYes
Functionality under WinCC (TIA Portal) / Archiving / Memory location / USB memoryYes
Functionality under WinCC (TIA Portal) / Archiving / Memory location / EthernetYes
Functionality under WinCC (TIA Portal) / Security / Number of user groups50
Functionality under WinCC (TIA Portal) / Security / Number of user rights32
Functionality under WinCC (TIA Portal) / Security / Number of users50
Functionality under WinCC (TIA Portal) / Security / Password export/importYes
Functionality under WinCC (TIA Portal) / Security / SIMATIC LogonYes
Functionality under WinCC (TIA Portal) / Logging through printer / AlarmsYes
Functionality under WinCC (TIA Portal) / Logging through printer / Report (shift log)Yes
Functionality under WinCC (TIA Portal) / Logging through printer / HardcopyYes
Functionality under WinCC (TIA Portal) / Logging through printer / Electronic print to fileYes; PDF, HTML
Functionality under WinCC (TIA Portal) / Character sets / Keyboard fonts / US EnglishYes
Functionality under WinCC (TIA Portal) / Transfer (upload/download) / MPI/PROFIBUS DPYes
Functionality under WinCC (TIA Portal) / Transfer (upload/download) / EthernetYes
Functionality under WinCC (TIA Portal) / Transfer (upload/download) / using external storage mediumYes
Functionality under WinCC (TIA Portal) / Process coupling / S7-1200Yes
Functionality under WinCC (TIA Portal) / Process coupling / S7-1500Yes
Functionality under WinCC (TIA Portal) / Process coupling / S7-200Yes
Functionality under WinCC (TIA Portal) / Process coupling / S7-300/400Yes
Functionality under WinCC (TIA Portal) / Process coupling / LOGO!Yes
Functionality under WinCC (TIA Portal) / Process coupling / WinACYes
Functionality under WinCC (TIA Portal) / Process coupling / SINUMERIKYes; with SINUMERIK option package
Functionality under WinCC (TIA Portal) / Process coupling / SIMOTIONYes
Functionality under WinCC (TIA Portal) / Process coupling / Allen Bradley (EtherNet/IP)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Allen Bradley (DF1)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Mitsubishi (MC TCP/IP)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Mitsubishi (FX)Yes
Functionality under WinCC (TIA Portal) / Process coupling / OMRON (FINS TCP)No
Functionality under WinCC (TIA Portal) / Process coupling / OMRON (Host Link)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Modicon (Modbus TCP/IP)Yes
Functionality under WinCC (TIA Portal) / Process coupling / Modicon (Modbus RTU)Yes
Functionality under WinCC (TIA Portal) / Process coupling / OPC UA ClientYes
Functionality under WinCC (TIA Portal) / Process coupling / OPC UA ServerYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / Backup/Restore manuallyYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / Backup/Restore automaticallyYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / SimulationYes
Functionality under WinCC (TIA Portal) / Service tools/configuration aids / Device switchoverYes
Peripherals/Options / PrinterYes
Peripherals/Options / SIMATIC HMI MM memory card: Multi Media CardYes; Up to 128 MB
Peripherals/Options / SIMATIC HMI SD memory card: Secure Digital memory cardYes; Up to 2 GB
Peripherals/Options / SIMATIC HMI CF memory card Compact Flash CardNo
Peripherals/Options / USB memoryYes
Peripherals/Options / SIMATIC IPC USB Flashdrive (USB stick)Yes; Up to 16 GB
Peripherals/Options / SIMATIC HMI USB stickYes; Up to 8 GB
Peripherals/Options / Network cameraYes
МатериалYes
МатериалNo
МатериалNo
Dimensions / Width of the housing front140 mm
Dimensions / Height of housing front116 mm
Dimensions / Mounting cutout, width124 mm
Dimensions / Mounting cutout, height100 mm
Dimensions / mounting depth48 mm
Масса0.6 kg