Технические характеристики

Data sheet designationSIMATIC ET 200SP, F-TM Count 1x1Vpp sin/cos HF, PROFIsafe, 1 channel, for incremental rotary encoders, sin/cos 1 Vpp, suitable for BU type A0, pack quantity: 1 unit
General information / Product type designationF-TM Count 1x1Vpp sin/cos HF
General information / Firmware versionV1.0
General information / FW update possibleYes
General information / usable BaseUnitsBU type A0
General information / Color code for module-specific color-coded labelCC01
General information / Product function / I&M dataYes; I&M0 to I&M3
General information / Engineering with / STEP 7 TIA Portal configurable/integrated from versionStep 7 V17 or higher: use GSDML for prior versions
Напряжение питания24 V
Напряжение питанияNo
Напряжение питания24 V
Напряжение питания20.4 V
Напряжение питания28.8 V
Напряжение питанияYes
Input current / Current consumption, max.50 mA; without load, 150 mA with 300 mA encoder load
Power loss / Power loss, typ.1.25 W
Address area / Address space per module / Inputs14 byte; S7-300/400F CPU, 13 byte
Address area / Address space per module / Outputs5 byte; S7-300/400F CPU, 4 byte
Hardware configuration / Automatic encodingYes
Hardware configuration / Electronic coding element type HYes
Digital inputs / Number of digital inputs1; (counter input)
Digital inputs / Digital inputs, parameterizableYes
Digital inputs / Digital input functions, parameterizable / Gate start/stopYes
Digital inputs / Digital input functions, parameterizable / Counter for incremental encoderYes
Digital inputs / Digital input functions, parameterizable / Number, max.1
Напряжение питанияsin/cos 1 Vpp
Напряжение питания2.5 µs
Напряжение питанияYes
Digital inputs / Cable length / shielded, max.150 m
Encoder / Connectable encoders / Incremental encoder (symmetrical)Yes; up to 200 kHz depending on cable type and length
Напряжение питания1 Vpp, centered at 2.5 V offset
Encoder / Encoder signals, incremental encoder (symmetrical) / Input frequency, max.200 kHz
Encoder / Encoder signals, incremental encoder (symmetrical) / Counting frequency, max.800 kHz; with quadruple evaluation
Encoder / Encoder signals, incremental encoder (symmetrical) / Cable length, shielded, max.150 m
Interrupts/diagnostics/status information / Diagnostics functionYes; see chapter "Diagnostic Messages" in the manual
Interrupts/diagnostics/status information / Alarms / Diagnostic alarmYes
Interrupts/diagnostics/status information / Alarms / Hardware interruptNo
Напряжение питанияYes
Interrupts/diagnostics/status information / Diagnoses / Wire breakYes
Interrupts/diagnostics/status information / Diagnoses / short-circuitYes
Interrupts/diagnostics/status information / Diagnoses / A/B transition error at incremental encoderYes
Interrupts/diagnostics/status information / Diagnostics indication LED / RUN LEDYes; green LED
Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LEDYes; red LED
Напряжение питанияYes; green LED
Interrupts/diagnostics/status information / Diagnostics indication LED / Channel status displayYes; green LED
Interrupts/diagnostics/status information / Diagnostics indication LED / for channel diagnosticsYes; red LED
Interrupts/diagnostics/status information / Diagnostics indication LED / for module diagnosticsYes; green/red DIAG LED
Integrated Functions / CounterYes
Integrated Functions / Number of counters1
Integrated Functions / Counting frequency, max.800 kHz; with quadruple evaluation
Integrated Functions / Safety monitoring functions / Safe Operating Stop (SOS)Yes
Integrated Functions / Safety monitoring functions / Safely-Limited Speed (SLS)Yes
Integrated Functions / Safety monitoring functions / Safe Direction (SDI)Yes
Integrated Functions / Safety monitoring functions / Safe Speed Monitor (SSM)Yes
Integrated Functions / Counting functions / Continuous countingYes
Integrated Functions / Counting functions / Counter response parameterizableYes
Integrated Functions / Measuring range / Frequency measurement, max.800 kHz; with quadruple evaluation
Integrated Functions / Measuring range / Cycle duration measurement, min.1 µs
Integrated Functions / Measuring range / Cycle duration measurement, max.25 s
Integrated Functions / Measuring range / Velocity measurement, min.0 (speed in configured units per selected time basis - speed*1 000)
Integrated Functions / Measuring range / Velocity measurement, max.2 147 483 (speed in configured units per selected time basis - speed*1 000)
Potential separation / Potential separation channels / between the channelsNo; Only one channel is available
Potential separation / Potential separation channels / between the channels and backplane busYes
СертификацияYes
СертификацияYes
Сертификация88.3 kg
Сертификация13.1 kg
Сертификация76.6 kg
СертификацияSIL 3
Сертификацияof 100 hours)
Сертификация< 2.00E-03 signal monitoring disabled
Сертификация< 3.00E-05
Сертификация< 3.00E-08 1/h signal monitoring disabled
Рабочая температура0 °C
Рабочая температура60 °C
Рабочая температура0 °C
Рабочая температура55 °C
Ambient conditions / Altitude during operation relating to sea level / Ambient air temperature-barometric pressure-altitudeOn request: Installation altitudes greater than 2 000 m
Dimensions / Width15 mm
Dimensions / Height73 mm
Dimensions / Depth58 mm
Получить предложение по этой позиции