ПЛК и системы автоматизации
SI

Siemens AG 6ES7138-6EB00-0BA0

Модуль ввода-вывода Siemens 6ES7138-6EB00-0BA0, серия ET200SP. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.

  • Бренд: Siemens AG
  • Артикул (MPN): 6ES7138-6EB00-0BA0
  • Серия: ET200SP Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationSIMATIC ET 200SP, TM PTO 2x24 V, interface module for stepper drives, 2 channels pulse train output, PTO: 24 V, 2 DI, 1 DQ 24 V DC per channel, suitable for BU type A0
General information / Product type designationTM PTO 2x24V
General information / usable BaseUnitsBU type A0
General information / Color code for module-specific color-coded labelCC00
General information / Product function / I&M dataYes; I&M0 to I&M3
General information / Product function / Isochronous modeYes
General information / Engineering with / STEP 7 TIA Portal configurable/integrated from versionSTEP 7 V17 with HSP or higher
General information / Engineering with / PROFIBUS from GSD version/GSD revisionOne GSD file each, Revision 3 and 5 and higher
General information / Engineering with / PROFINET from GSD version/GSD revisionGSDML V2.35
Напряжение питания24 V
Напряжение питания24 V
Напряжение питания19.2 V
Напряжение питания28.8 V
Напряжение питанияYes
Input current / Current consumption, max.50 mA; without load
Power loss / Power loss, typ.1.5 W
Address area / Address space per module / Inputs32 byte
Address area / Address space per module / Outputs16 byte
Hardware configuration / Automatic encodingYes
Hardware configuration / Mechanical coding elementYes
Digital inputs / Number of digital inputs6; 3 per channel
Digital inputs / Digital inputs, parameterizableYes
Digital inputs / Input characteristic curve in accordance with IEC 61131, type 3Yes
Digital inputs / Digital input functions, parameterizable / SynchronizationYes
Digital inputs / Digital input functions, parameterizable / ProbeYes
Digital inputs / Digital input functions, parameterizable / Drive readyYes
Напряжение питания24 V
Напряжение питания-5 ... +5 V
Напряжение питания+11 to +30V
Напряжение питания-30 V; -5 V continuous, -30 V brief reverse polarity protection
Напряжение питания30 V
Digital inputs / Cable length / shielded, max.1 000 m
Digital inputs / Cable length / unshielded, max.600 m
Digital outputs / Number of digital outputs6; 3 per channel
Digital outputs / Current-sinkingYes; push-pull outputs for 24 V PTO outputs
Digital outputs / Current-sourcingYes
Digital outputs / Digital outputs, parameterizableYes
Digital outputs / Short-circuit protectionYes; electronic/thermal
Digital outputs / Response threshold, typ.1 A
Digital outputs / Controlling a digital inputYes
Digital outputs / Digital output functions, parameterizable / PTO (pulse train output) signal interfaceYes
Digital outputs / Digital output functions, parameterizable / 24 V asymmetricalYes
Digital outputs / Digital output functions, parameterizable / PTO (pulse train output) signal type / Pulse and directionYes
Digital outputs / Digital output functions, parameterizable / PTO (pulse train output) signal type / Count up, count downYes
Digital outputs / Digital output functions, parameterizable / PTO (pulse train output) signal type / Incremental encoder (A, B phase shift)Yes
Digital outputs / Digital output functions, parameterizable / PTO (pulse train output) signal type / Incremental encoder (A, B phase shift, quadruple)Yes
Digital outputs / Switching capacity of the outputs / with resistive load, max.0.1 A; 0.5 A for CHn.ED
Digital outputs / Switching capacity of the outputs / on lamp load, max.1 W; 5 W for CHn.ED
Digital outputs / Load resistance range / lower limit240 Ω; 48 ohms for CHn.ED
Digital outputs / Load resistance range / upper limit12 kΩ
Напряжение питания23.2 V; L+ (-1.3 V), L+ (-0.8 V) for CHn.ED
Digital outputs / Output current / for signal "1" rated value0.1 A; 0.5 A for CHn.ED
Digital outputs / Output current / for signal "1" permissible range, max.0.12 A; 0.6 A for CHn.ED
Digital outputs / Output current / for signal "1" minimum load current2 mA
Digital outputs / Output current / for signal "0" residual current, max.0.5 mA
Digital outputs / Switching frequency / with resistive load, max.10 kHz
Digital outputs / Switching frequency / with inductive load, max.0.5 Hz; According to IEC 60947-5-1, DC-13
Digital outputs / Switching frequency / on lamp load, max.10 Hz
Digital outputs / Switching frequency / For signal interface 24 V asymmetrical200 kHz; For 24 V PTO outputs
Digital outputs / Total current of the outputs / Current per module, max.1.4 A
Digital outputs / Cable length / shielded, max.600 m; Up to 10 kHz, 50 m at 200 kHz
Interfaces / Number of RS 485 interfaces0
Interrupts/diagnostics/status information / Alarms / Diagnostic alarmYes
Напряжение питанияYes
Interrupts/diagnostics/status information / Diagnoses / Short-circuitYes
Напряжение питанияYes; green PWR LED
Interrupts/diagnostics/status information / Diagnostics indication LED / Channel status displayYes; green LED
Interrupts/diagnostics/status information / Diagnostics indication LED / for module diagnosticsYes; green/red DIAG LED
Potential separation / Potential separation channels / between the channels and backplane busYes
Isolation / Isolation tested with707 V DC (type test)
СертификацияNo
Рабочая температура-30 °C
Рабочая температура60 °C; Observe derating
Рабочая температура-30 °C
Рабочая температура50 °C; Observe derating
Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Ambient conditions / Absolute humidity / dew point, min.-60 °C; suitable for dry room applications
Decentralized operation / to SIMATIC S7-300Yes; Via control and feedback interface
Decentralized operation / to SIMATIC S7-400Yes; Via control and feedback interface
Decentralized operation / to SIMATIC S7-1200Yes
Decentralized operation / to SIMATIC S7-1500Yes
Decentralized operation / to standard PROFIBUS masterYes; Via control and feedback interface
Decentralized operation / to standard PROFINET controllerYes; Via control and feedback interface
Dimensions / Width15 mm
Dimensions / Height73 mm
Dimensions / Depth58 mm
Получить предложение по этой позиции