| Data sheet designation | SIMATIC ET 200SP MultiFieldbus interface module IM 155-6 MF High Feature, PN IO, Ethernet IP, Modbus TCP, max. 64 I/O modules and 16 ET 200AL modules, S2 redundancy, multi hot swap, 0.25 ms, isochronous mode, optional PN strain relief PN security class 1 including server module (6ES7193-6PA00-0AA0) |
|---|---|
| General information / Product type designation | IM 155-6 MF HF |
| General information / Firmware version | V6.4.1 |
| General information / FW update possible | Yes |
| General information / Vendor identification (VendorID) | 002AH |
| General information / Device identifier (DeviceID) | 0313H |
| General information / Manufacturer ID according to ODVA (VendorID) | 0x04E3 |
| General information / Device ID according to ODVA (Product code) | 0FA2H |
| General information / Product function / I&M data | Yes; I&M0 to I&M4 |
| General information / Product function / Module swapping during operation (hot swapping) | Yes; Multi-hot swapping |
| General information / Product function / Isochronous mode | Yes |
| General information / Product function / Tool changer | Yes; Docking station and docking unit |
| General information / Product function / Local coupling, IO data | Yes |
| General information / Product function / Number of coupling modules | 6; 1x output + max. 5x input |
| General information / Engineering with / STEP 7 TIA Portal configurable/integrated from version | V20 |
| General information / Engineering with / STEP 7 configurable/integrated from version | V5.7 SP3 |
| General information / Engineering with / PROFINET from GSD version/GSD revision | GSDML V2.45 |
| General information / Engineering with / Multi Fieldbus Configuration Tool (MFCT) | V1.5.2.0 or higher |
| Configuration control / via dataset | Yes |
| Напряжение питания | 24 V |
| Напряжение питания | 19.2 V |
| Напряжение питания | 28.8 V |
| Напряжение питания | Yes |
| Напряжение питания | Yes |
| Напряжение питания | 10 ms |
| Input current / Current consumption (rated value) | 550 mA |
| Input current / Current consumption, max. | 650 mA |
| Input current / Inrush current, max. | 1 A |
| Power loss / Power loss, typ. | 2 W |
| Address area / Address space per module / Address space per module, max. | 288 byte; For input and output data respectively |
| Address area / Address space per station / Address space per station, max. | 1 440 byte |
| Hardware configuration / Rack / Quantity of operable ET 200SP modules, max. | 64 |
| Hardware configuration / Rack / Quantity of operable ET 200AL modules, max. | 16 |
| Hardware configuration / Submodules / Number of submodules per station, max. | 256 |
| Interfaces / Transmission procedure | 100BASE-TX |
| Interfaces / Number of PROFINET interfaces | 1; 2 ports (switch) |
| 1. Interface / Interface types / RJ 45 (Ethernet) | Yes; with BusAdapter |
| 1. Interface / Interface types / Number of ports | 2; with BusAdapter |
| 1. Interface / Interface types / integrated switch | Yes |
| 1. Interface / Interface types / BusAdapter (PROFINET) | Yes; BA 2x RJ45, BA 2x M12, BA 2x FC |
| 1. Interface / Protocols / PROFINET IO device | Yes |
| 1. Interface / Services / Dynamic Frame Packing (DFP) | Yes |
| 1. Interface / Services / Fast Forwarding | Yes |
| 1. Interface / Services / Fragmentation | Yes |
| 1. Interface / Services / PROFIenergy | Yes |
| 1. Interface / Services / Prioritized startup | Yes |
| 1. Interface / Services / Shared device | Yes |
| 1. Interface / Services / Number of IO Controllers with shared device, max. | 14; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master |
| Interface types / RJ 45 (Ethernet) / Transmission procedure | PROFINET with 100 Mbit/s full duplex (100BASE-TX) |
| Interface types / RJ 45 (Ethernet) / 100 Mbps | Yes |
| Interface types / RJ 45 (Ethernet) / Autonegotiation | Yes |
| Interface types / RJ 45 (Ethernet) / Autocrossing | Yes |
| Protocols / Supports protocol for PROFINET IO | Yes |
| Protocols / PROFIsafe | Yes |
| Protocols / PROFIBUS | No |
| Protocols / EtherNet/IP | Yes |
| Protocols / Modbus TCP | Yes |
| Protocols / Redundancy mode / PROFINET system redundancy (R1) | No |
| Protocols / Redundancy mode / H-Sync forwarding | Yes |
| Protocols / Services / CIP Explicit Messaging | Yes |
| Protocols / Services / CIP Safety | No |
| Protocols / Services / Configuration control via Explicit Messaging | No |
| Protocols / Services / Shared device | Yes; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master |
| Protocols / Services / Number of scanners with shared device, max. | 2 |
| Protocols / Updating times / Requested Packet Interval (RPI) | 2 ms |
| Protocols / Address area / Address space per module, max. | 288 byte; (246 byte outputs / 288 byte inputs) |
| Protocols / Address area / ForwardOpen (Class1 & 32 bit Header) | 500 byte; (246 byte outputs / 500 byte inputs) |
| Protocols / Address area / LargeForwardOpen (Class3) | 4 002 byte |
| Protocols / Services / read discrete inputs (code=2) | Yes |
| Protocols / Services / Read Holding Registers (Code=3) | Yes |
| Protocols / Services / Read Input Register (Code=4) | Yes |
| Protocols / Services / write single coil (code=5) | Yes |
| Protocols / Services / Write Single Register (Code=6) | Yes |
| Protocols / Services / write multiple coils (code=15) | Yes |
| Protocols / Services / Write Multiple Registers (Code=16) | Yes |
| Protocols / Services / Read/Write Multiple Registers (Code=23) | Yes |
| Protocols / Services / Parameter change by master | Yes |
| Protocols / Services / Modbus TCP Security Protocol | No |
| Protocols / Address space per station / Address space per station, max. | 500 byte; (246 byte outputs / 500 byte inputs) |
| Protocols / Address space per station / Access-consistent address space | 250 byte; (246 byte outputs / 250 byte inputs) |
| Protocols / Updating time / I/O request interval | 2 ms |
| Protocols / Connections / number of connections per device | 9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info) |
| Protocols / Open IE communication / TCP/IP | Yes |
| Protocols / Open IE communication / SNMP | Yes |
| Protocols / Open IE communication / LLDP | Yes |
| Protocols / Open IE communication / IGMP | Yes |
| Protocols / Open IE communication / Multicast | Yes |
| Protocols / Open IE communication / Broadcast | Yes |
| Protocols / Open IE communication / IPv4 | Yes |
| Protocols / Open IE communication / IPv6 | No |
| Isochronous mode / Equidistance | Yes |
| Isochronous mode / shortest clock pulse | 250 µs |
| Isochronous mode / max. cycle | 4 ms |
| Isochronous mode / Bus cycle time (TDP), min. | 250 µs |
| Isochronous mode / Jitter, max. | 1 µs |
| Interrupts/diagnostics/status information / Status indicator | Yes |
| Interrupts/diagnostics/status information / Alarms | Yes |
| Interrupts/diagnostics/status information / Diagnostics function | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / RUN LED | Yes; green LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LED | Yes; red LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / MAINT LED | Yes; Yellow LED |
| Напряжение питания | Yes; green PWR LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / NS LED | Yes; green/red LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / MS LED | Yes; green/red LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / IO LED | Yes; red-green-yellow LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Connection display LINK TX/RX | Yes; 2x green link LEDs on BusAdapter |
| Potential separation / between backplane bus and electronics | No |
| Potential separation / between PROFINET and all other circuits | Yes; 1500 V AC (type test) |
| Potential separation / between supply and all other circuits | No |
| Permissible potential difference / between different circuits | Safety extra low voltage SELV |
| Isolation / Isolation tested with | 707 V DC (type test) |
| Сертификация | 3 |
| Security / PROFINET Security Class | 1 |
| Security / signed firmware update | Yes |
| Security / Secure Boot | No |
| Security / securely removing data | Yes |
| Security / data integrity | Yes |
| Рабочая температура | -30 °C; No condensation |
| Рабочая температура | 60 °C |
| Рабочая температура | -30 °C; No condensation |
| Рабочая температура | 50 °C |
| Connection method / ET-Connection / via BU/BA Send | Yes; + 16 ET 200AL modules |
| Материал | Yes; Optional |
| Dimensions / Width | 50 mm |
| Dimensions / Height | 117 mm |
| Dimensions / Depth | 74 mm |