SI
Siemens AG 6ES7512-1CM03-0AB0
Компонент системы автоматизации Siemens 6ES7512-1CM03-0AB0, серия S7-1500. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.
Категории:
Технические характеристики
| Data sheet designation | SIMATIC S7-1500 compact CPU, CPU 1512C-1 PN, central processing unit with work memory: 400 KB for program and 2 MB for data, 32 digital inputs, 32 digital outputs, 5 analog inputs, 2 analog outputs, 6 high-speed counters, 4 fast outputs for PTO/PWM/frequency output, 1st interface: PROFINET IRT with 2-port switch, 6 ns bit performance, including front connector push-in, SIMATIC Memory Card required |
|---|---|
| General information / Product type designation | CPU 1512C-1 PN |
| General information / HW functional status | FS01 |
| General information / Firmware version | V4.1 |
| General information / FW update possible | Yes |
| General information / Product function / I&M data | Yes; I&M0 to I&M3 |
| General information / Product function / Isochronous mode | Yes; with minimal OB 6x cycle of 500 μs (distributed) |
| General information / Product function / SysLog | Yes |
| Display / Screen diagonal [cm] | 3.45 cm |
| Control elements / Number of keys | 8 |
| Control elements / Mode buttons | 2 |
| Напряжение питания | 24 V |
| Напряжение питания | 19.2 V; 20.4 V DC, for supplying the digital inputs/outputs |
| Напряжение питания | 28.8 V |
| Напряжение питания | Yes |
| Напряжение питания | 5 ms; Refers to the power supply on the CPU section |
| Напряжение питания | 1/s |
| Input current / Current consumption (rated value) | 0.66 A; without DI/DO load |
| Input current / Current consumption, max. | 1 A; without DI/DO load |
| Input current / Inrush current, max. | 1.22 A; Rated value |
| Напряжение питания | 20 mA; per group |
| Напряжение питания | 30 mA; Per group, without load |
| Encoder supply / Number of outputs | 2; One common 24 V encoder supply per 16 digital inputs |
| Encoder supply / 24 V encoder supply / 24 V | Yes; L+ (-0.8 V) |
| Encoder supply / 24 V encoder supply / Short-circuit protection | Yes |
| Encoder supply / 24 V encoder supply / Output current, max. | 1 A |
| Power / Infeed power to the backplane bus | 10 W |
| Power / Power consumption from the backplane bus (balanced) | 9 W |
| Power loss / Power loss, typ. | 6 W |
| Storage / Number of slots for SIMATIC memory card | 1 |
| Storage / SIMATIC memory card required | Yes |
| Storage / Work memory / integrated (for program) | 400 kbyte |
| Storage / Work memory / integrated (for data) | 2 Mbyte |
| Storage / Load memory / Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
| Storage / Backup / maintenance-free | Yes |
| CPU processing times / for bit operations, typ. | 6 ns |
| CPU processing times / for word operations, typ. | 7 ns |
| CPU processing times / for fixed point arithmetic, typ. | 9 ns |
| CPU processing times / for floating point arithmetic, typ. | 37 ns |
| CPU-blocks / Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
| CPU-blocks / Nesting depth / per priority class | 24 |
| Counters, timers and their retentivity / S7 counter / Number | 2 048 |
| Counters, timers and their retentivity / S7 counter / Retentivity / adjustable | Yes |
| Counters, timers and their retentivity / IEC counter / Number | Any (only limited by the main memory) |
| Counters, timers and their retentivity / IEC counter / Retentivity / can be set | Yes |
| Counters, timers and their retentivity / S7 timer / Number | 2 048 |
| Counters, timers and their retentivity / S7 timer / Retentivity / adjustable | Yes |
| Counters, timers and their retentivity / IEC timer / Number | Any (only limited by the main memory) |
| Counters, timers and their retentivity / IEC timer / Retentivity / can be set | Yes |
| Data areas and their retentivity / Flag / Size, max. | 16 kbyte |
| Data areas and their retentivity / Flag / Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data areas and their retentivity / Data blocks / Retentivity adjustable | Yes |
| Data areas and their retentivity / Data blocks / Retentivity preset | No |
| Data areas and their retentivity / Local data / per priority class, max. | 64 kbyte; max. 16 KB per block |
| Address area / Number of IO modules | 2 048; max. number of modules / submodules |
| Address area / I/O address area / Inputs | 32 kbyte; All inputs are in the process image |
| Address area / I/O address area / Outputs | 32 kbyte; All outputs are in the process image |
| Address area / I/O address area / per integrated IO subsystem / Inputs (volume) | 8 kbyte |
| Address area / I/O address area / per integrated IO subsystem / Outputs (volume) | 8 kbyte |
| Address area / I/O address area / per CM/CP / Inputs (volume) | 8 kbyte |
| Address area / I/O address area / per CM/CP / Outputs (volume) | 8 kbyte |
| Address area / Subprocess images / Number of subprocess images, max. | 32 |
| Hardware configuration / Rack / Number of lines, max. | 1 |
| Time of day / Clock / Type | Hardware clock |
| Time of day / Clock / Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Time of day / Clock / Deviation per day, max. | 10 s; Typ.: 2 s |
| Time of day / Operating hours counter / Number | 64 |
| Time of day / Clock synchronization / supported | Yes |
| Time of day / Clock synchronization / to DP, master | Yes; via PROFIBUS CM / CP |
| Time of day / Clock synchronization / on DP, device | Yes; via PROFIBUS CM / CP |
| Time of day / Clock synchronization / in AS, master | Yes |
| Time of day / Clock synchronization / in AS, device | Yes |
| Time of day / Clock synchronization / on Ethernet via NTP | Yes |
| Digital inputs / integrated channels (DI) | 32 |
| Digital inputs / Digital inputs, parameterizable | Yes |
| Digital inputs / Sourcing/sinking input | P-reading |
| Digital inputs / Input characteristic curve in accordance with IEC 61131, type 3 | Yes |
| Digital inputs / Digital input functions, parameterizable / Gate start/stop | Yes |
| Digital inputs / Digital input functions, parameterizable / Capture | Yes |
| Digital inputs / Digital input functions, parameterizable / Synchronization | Yes |
| Напряжение питания | DC |
| Напряжение питания | 24 V |
| Напряжение питания | -3 to +5V |
| Напряжение питания | +11 to +30V |
| Digital inputs / for standard inputs / at "0" to "1", min. | 4 µs; for parameterization "none" |
| Digital inputs / for standard inputs / at "0" to "1", max. | 20 ms |
| Digital inputs / for standard inputs / at "1" to "0", min. | 4 µs; for parameterization "none" |
| Digital inputs / for standard inputs / at "1" to "0", max. | 20 ms |
| Digital inputs / for interrupt inputs / Parameterizable | Yes; Same as for standard inputs |
| Digital inputs / for technological functions / Parameterizable | Yes; Same as for standard inputs |
| Digital outputs / Type of digital output | Transistor |
| Digital outputs / integrated channels (DO) | 32 |
| Digital outputs / Current-sourcing | Yes; Push-pull output |
| Digital outputs / Short-circuit protection | Yes; electronic/thermal |
| Digital outputs / Response threshold, typ. | 1.6 A with standard output, 0.5 A with high-speed output; see manual for details |
| Напряжение питания | Connector X11: -0.8 V; connector X12: L+ (-53 V) |
| Digital outputs / Controlling a digital input | Yes |
| Digital outputs / Accuracy of pulse duration | Up to ±100 ppm ±2 μs at high-speed output; see manual for details |
| Digital outputs / minimum pulse duration | 2 µs; With High Speed output |
| Digital outputs / Digital output functions, parameterizable / Switching tripped by comparison values | Yes; As output signal of a high-speed counter |
| Digital outputs / Digital output functions, parameterizable / PWM output | Yes |
| Digital outputs / Digital output functions, parameterizable / Number, max. | 4 |
| Digital outputs / Digital output functions, parameterizable / Cycle duration, parameterizable | Yes |
| Digital outputs / Digital output functions, parameterizable / ON period, min. | 0 % |
| Digital outputs / Digital output functions, parameterizable / ON period, max. | 100 % |
| Digital outputs / Digital output functions, parameterizable / Resolution of the duty cycle | 0.0036 %; For S7 analog format, min. 40 ns |
| Digital outputs / Digital output functions, parameterizable / Frequency output | Yes |
| Digital outputs / Output delay with resistive load / "0" to "1", max. | 200 µs |
| Digital outputs / Output delay with resistive load / "1" to "0", max. | 500 µs; Load-dependent |
| Digital outputs / Output delay with resistive load / for technological functions / "0" to "1", max. | 5 µs; Depending on the output used, see additional description in manual |
| Digital outputs / Output delay with resistive load / for technological functions / "1" to "0", max. | 5 µs; Depending on the output used, see additional description in manual |
| Digital outputs / Parallel switching of two outputs / for logic links | Yes; for technological functions: No |
| Digital outputs / Parallel switching of two outputs / for uprating | No |
| Digital outputs / Parallel switching of two outputs / for redundant control of a load | Yes; for technological functions: No |
| Digital outputs / Switching frequency / with resistive load, max. | 100 kHz; For high-speed output, 100 Hz for standard output |
| Digital outputs / Switching frequency / with inductive load, max. | 0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve |
| Digital outputs / Switching frequency / on lamp load, max. | 10 Hz |
| Digital outputs / Total current of the outputs / Current per channel, max. | 0.5 A; see additional description in the manual |
| Digital outputs / Relay outputs / Number of relay outputs | 0 |
| Analog inputs / Number of analog inputs | 5; 4x for U/I, 1x for R/RTD |
| Analog inputs / For current measurement | 4; max. |
| Напряжение питания | 4; max. |
| Analog inputs / For resistance/resistance thermometer measurement | 1 |
| Напряжение питания | Yes; Physical measuring range: ± 10 V |
| Напряжение питания | 100 kΩ |
| Напряжение питания | Yes; Physical measuring range: ± 10 V |
| Напряжение питания | 100 kΩ |
| Напряжение питания | Yes |
| Напряжение питания | 100 kΩ |
| Напряжение питания | Yes; Physical measuring range: ± 10 V |
| Напряжение питания | 100 kΩ |
| Analog inputs / Input ranges (rated values), currents / 0 to 20 mA | Yes; Physical measuring range: ± 20 mA |
| Analog inputs / Input ranges (rated values), currents / Input resistance (0 to 20 mA) | 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC |
| Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mA | Yes |
| Analog inputs / Input ranges (rated values), currents / Input resistance (-20 mA to +20 mA) | 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC |
| Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mA | Yes; Physical measuring range: ± 20 mA |
| Analog inputs / Input ranges (rated values), currents / Input resistance (4 mA to 20 mA) | 50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC |
| Analog inputs / Input ranges (rated values), resistance thermometer / Ni 100 | Yes; Standard/climate |
| Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Ni 100) | 10 MΩ |
| Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100 | Yes; Standard/climate |
| Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Pt 100) | 10 MΩ |
| Analog inputs / Input ranges (rated values), resistors / 0 to 150 ohms | Yes; Physical measuring range: 0 ... 600 ohms |
| Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 150 ohms) | 10 MΩ |
| Analog inputs / Input ranges (rated values), resistors / 0 to 300 ohms | Yes; Physical measuring range: 0 ... 600 ohms |
| Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 300 ohms) | 10 MΩ |
| Analog inputs / Input ranges (rated values), resistors / 0 to 600 ohms | Yes |
| Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 600 ohms) | 10 MΩ |
| Analog inputs / Cable length / shielded, max. | 800 m; for U/I, 200 m for R/RTD |
| Analog outputs / integrated channels (AO) | 2 |
| Напряжение питания | Yes |
| Напряжение питания | Yes |
| Analog outputs / Output ranges, current / 0 to 20 mA | Yes |
| Analog outputs / Output ranges, current / -20 mA to +20 mA | Yes |
| Analog outputs / Output ranges, current / 4 mA to 20 mA | Yes |
| Напряжение питания | 1 kΩ |
| Напряжение питания | 100 nF |
| Analog outputs / Load impedance (in rated range of output) / with current outputs, max. | 500 Ω |
| Analog outputs / Load impedance (in rated range of output) / with current outputs, inductive load, max. | 1 mH |
| Analog outputs / Cable length / shielded, max. | 200 m |
| Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 16 bit |
| Analog value generation for the inputs / Smoothing of measured values / Step: None | Yes |
| Analog value generation for the inputs / Smoothing of measured values / Step: low | Yes |
| Analog value generation for the inputs / Smoothing of measured values / Step: Medium | Yes |
| Analog value generation for the inputs / Smoothing of measured values / Step: High | Yes |
| Analog value generation for the outputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max. | 16 bit |
| Analog value generation for the outputs / Settling time / for resistive load | 1.5 ms |
| Analog value generation for the outputs / Settling time / for capacitive load | 2.5 ms |
| Analog value generation for the outputs / Settling time / for inductive load | 2.5 ms |
| Напряжение питания | Yes |
| Encoder / Connection of signal encoders / for current measurement as 4-wire transducer | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with two-wire connection | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with three-wire connection | Yes |
| Encoder / Connection of signal encoders / for resistance measurement with four-wire connection | Yes |
| Encoder / Connectable encoders / 2-wire sensor | Yes |
| Encoder / Connectable encoders / permissible quiescent current (2-wire sensor), max. | 1.5 mA |
| Напряжение питания | 24 V |
| Encoder / Encoder signals, incremental encoder (asymmetrical) / Input frequency, max. | 100 kHz |
| Encoder / Encoder signals, incremental encoder (asymmetrical) / Counting frequency, max. | 400 kHz; with quadruple evaluation |
| Encoder / Encoder signals, incremental encoder (asymmetrical) / Signal filter, parameterizable | Yes |
| Encoder / Encoder signals, incremental encoder (asymmetrical) / Incremental encoder with A/B tracks, 90° phase offset | Yes |
| Encoder / Encoder signals, incremental encoder (asymmetrical) / pulse encoder | Yes |
| Encoder / Encoder signals, incremental encoder (asymmetrical) / pulse encoder with direction | Yes |
| Encoder / Encoder signals, incremental encoder (asymmetrical) / pulse encoder with one impulse signal per count direction | Yes |
| Errors/accuracies / Linearity error (relative to input range), (+/-) | 0.1 % |
| Errors/accuracies / Temperature error (relative to input range), (+/-) | 0.005 %/K |
| Errors/accuracies / Operational error limit in overall temperature range / Current, relative to input range, (+/-) | 0.3 % |
| Напряжение питания | 0.2 % |
| Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-) | 0.2 % |
| Напряжение питания | frequency |
| Errors/accuracies / Series mode interference (peak value of interference < | 30 dB |
| Напряжение питания | 10 V |
| Errors/accuracies / Common mode interference, min. | 60 dB; at 400 Hz: 50 dB |
| Interfaces / Number of PROFINET interfaces | 1 |
| 1. Interface / Interface types / RJ 45 (Ethernet) | Yes; X1 |
| 1. Interface / Interface types / Number of ports | 2 |
| 1. Interface / Interface types / integrated switch | Yes |
| 1. Interface / Protocols / IP protocol | Yes; IPv4 |
| 1. Interface / Protocols / PROFINET IO Controller | Yes |
| 1. Interface / Protocols / PROFINET IO device | Yes |
| 1. Interface / Protocols / SIMATIC communication | Yes |
| 1. Interface / Protocols / Open IE communication | Yes; Optionally also encrypted |
| 1. Interface / Services / Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| 1. Interface / Services / Dynamic Frame Packing (DFP) | Yes |
| 1. Interface / Services / PROFIenergy | Yes; per user program |
| 1. Interface / Services / of which in line, max. | 128 |
| 1. Interface / Services / Number of IO Devices that can be simultaneously | 8; in total across all interfaces |
| 1. Interface / Update time for IRT / for send cycle of 2 ms | 2 ms to 32 ms |
| 1. Interface / Update time for RT / for send cycle of 500 µs | 500 µs to 256 ms |
| 1. Interface / Update time for RT / for send cycle of 1 ms | 1 ms to 512 ms |
| 1. Interface / Services / Dynamic Frame Packing (DFP) #2 | No |
| 1. Interface / Services / Prioritized startup | Yes |
| 1. Interface / Services / Shared device | Yes |
| 1. Interface / Services / Number of IO Controllers with shared device, max. | 4 |
| 1. Interface / Services / activation/deactivation of I-devices | Yes; per user program |
| 1. Interface / Services / Asset management record | Yes; per user program |
| Interface types / RJ 45 (Ethernet) / Autonegotiation | Yes |
| Interface types / RJ 45 (Ethernet) / Autocrossing | Yes |
| Interface types / RJ 45 (Ethernet) / Industrial Ethernet status LED | Yes |
| Protocols / Number of connections / Number of connections, max. | 128; via integrated interfaces of the CPU and connected CPs / CMs |
| Protocols / Number of connections / Number of connections reserved for ES/HMI/web | 10 |
| Protocols / Number of connections / Number of connections via integrated interfaces | 88 |
| Protocols / Number of connections / Number of S7 routing paths | 16 |
| Protocols / Redundancy mode / PROFINET system redundancy (S2) | No |
| Protocols / Redundancy mode / PROFINET system redundancy (R1) | No |
| Protocols / Redundancy mode / H-Sync forwarding | Yes |
| Protocols / Redundancy mode / Media redundancy / Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| Protocols / Redundancy mode / Media redundancy / Number of stations in the ring, max. | 50 |
| Protocols / SIMATIC communication / PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| Protocols / SIMATIC communication / S7 routing | Yes |
| Protocols / SIMATIC communication / Data record routing | Yes |
| Protocols / SIMATIC communication / S7 communication, as server | Yes |
| Protocols / SIMATIC communication / S7 communication, as client | Yes |
| Protocols / SIMATIC communication / User data per job, max. | See online help (S7 communication, user data size) |
| Protocols / Open IE communication / TCP/IP | Yes |
| Protocols / Open IE communication / Data length, max. | 64 kbyte |
| Protocols / Open IE communication / several passive connections per port, supported | Yes |
| Protocols / Open IE communication / ISO-on-TCP (RFC1006) | Yes |
| Protocols / Open IE communication / Data length, max. #2 | 2 kbyte; 1 472 bytes for UDP broadcast |
| Protocols / Open IE communication / UDP multicast | Yes; max. 78 multicast circuits |
| Protocols / Open IE communication / DHCP | Yes |
| Protocols / Open IE communication / SNMP | Yes |
| Protocols / Open IE communication / LLDP | Yes |
| Protocols / Open IE communication / Encryption | Yes; Optional |
| Protocols / Web server / HTTP | Yes; Standard and user pages |
| Protocols / Web server / HTTPS | Yes; Standard and user pages |
| Protocols / Web server / web API / Number of sessions, max. | 50 |
| Protocols / Web server / web API / number of simultaneous HTTP calls, max. | 4 |
| Protocols / Web server / web API / HTTP request body, max. | 131 072 byte |
| Protocols / OPC UA / Runtime license required | Yes; "Small" license required |
| Protocols / OPC UA / OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
| Protocols / OPC UA / Number of nodes of the client interfaces, | 1 000 |
| Protocols / OPC UA / Number of elements for one call of | 100 |
| Protocols / OPC UA / Number of registerable nodes, max. | 5 000 |
| Protocols / OPC UA / Number of registerable method calls of | 100 |
| Protocols / OPC UA / Number of sessions, max. | 32 |
| Protocols / OPC UA / Number of accessible variables, max. | 50 000 |
| Protocols / OPC UA / Number of registerable nodes, max. #2 | 10 000 |
| Protocols / OPC UA / Number of subscriptions per session, max. | 50 |
| Protocols / OPC UA / Sampling interval, min. | 100 ms |
| Protocols / OPC UA / Number of alarms for system diagnostics | 50 |
| Protocols / Further protocols / MODBUS | Yes; MODBUS TCP |
| S7 message functions / Number of login stations for message functions, max. | 32 |
| S7 message functions / number of subscriptions, max. | 250 |
| S7 message functions / number of tags/attributes for subscriptions, max. | 2 000 |
| S7 message functions / Number of simultaneously active program alarms / Number of program alarms | 600 |
| S7 message functions / Number of simultaneously active program alarms / Number of alarms for system diagnostics | 100 |
| S7 message functions / Number of simultaneously active program alarms / Number of alarms for motion technology objects | 160 |
| Test commissioning functions / Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems |
| Test commissioning functions / Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
| Test commissioning functions / Single step | No |
| Test commissioning functions / Number of breakpoints | 8 |
| Test commissioning functions / Profiling | Yes |
| Test commissioning functions / Status/control / Status/control variable | Yes |
| Test commissioning functions / Status/control / Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Test commissioning functions / Status/control / Number of variables, max. / of which status variables, max. | 200; per job |
| Test commissioning functions / Status/control / Number of variables, max. / of which control variables, max. | 200; per job |
| Test commissioning functions / Forcing / Forcing | Yes |
| Test commissioning functions / Forcing / Forcing, variables | Peripheral inputs/outputs |
| Test commissioning functions / Forcing / Number of variables, max. | 200 |
| Test commissioning functions / Diagnostic buffer / present | Yes |
| Test commissioning functions / Diagnostic buffer / Number of entries, max. | 1 000 |
| Test commissioning functions / Diagnostic buffer / of which powerfail-proof | 500 |
| Test commissioning functions / Traces / Number of configurable Traces | 4 |
| Test commissioning functions / Traces / Memory size per trace, max. | 512 kbyte |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | Yes |
| Interrupts/diagnostics/status information / Alarms / Hardware interrupt | Yes |
| Напряжение питания | Yes |
| Interrupts/diagnostics/status information / Diagnoses / Wire break | Yes; for analog inputs/outputs, see description in manual |
| Interrupts/diagnostics/status information / Diagnoses / short-circuit | Yes; for analog outputs, see description in manual |
| Interrupts/diagnostics/status information / Diagnoses / A/B transition error at incremental encoder | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / RUN/STOP LED | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LED | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / MAINT LED | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / STOP ACTIVE LED | Yes |
| Напряжение питания | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Channel status display | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / for channel diagnostics | Yes; For analog inputs/outputs |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Connection display LINK TX/RX | Yes |
| Supported technology objects / Required Motion Control resources / per speed-controlled axis | 40 |
| Supported technology objects / Required Motion Control resources / per positioning axis | 80 |
| Supported technology objects / Required Motion Control resources / per synchronous axis | 160 |
| Supported technology objects / Required Motion Control resources / per external encoder | 80 |
| Supported technology objects / Required Motion Control resources / per output cam | 20 |
| Supported technology objects / Required Motion Control resources / per cam track | 160 |
| Supported technology objects / Required Motion Control resources / per probe | 40 |
| Supported technology objects / Positioning axis / Number of positioning axes at motion control cycle | 11 |
| Supported technology objects / Controller / PID_3Step | Yes; PID controller with integrated optimization for valves |
| Supported technology objects / Controller / PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Supported technology objects / Counting and measuring / High-speed counter | Yes |
| Integrated Functions / Counter / Number of counters | 6 |
| Integrated Functions / Counter / Counting frequency, max. | 400 kHz; with quadruple evaluation |
| Integrated Functions / Counting functions / Continuous counting | Yes |
| Integrated Functions / Counting functions / Counter response parameterizable | Yes |
| Integrated Functions / Counting functions / Hardware gate via digital input | Yes |
| Integrated Functions / Counting functions / Software gate | Yes |
| Integrated Functions / Counting functions / Event-controlled stop | Yes |
| Integrated Functions / Counting functions / Synchronization via digital input | Yes |
| Integrated Functions / Counting functions / Counting range, parameterizable | Yes |
| Integrated Functions / Counting functions / Comparator / Number of comparators | 2; per count channel; see manual for details |
| Integrated Functions / Counting functions / Comparator / Direction dependency | Yes |
| Integrated Functions / Counting functions / Comparator / Can be changed from user program | Yes |
| Integrated Functions / Position detection / Incremental acquisition | Yes |
| Integrated Functions / Position detection / Suitable for S7-1500 Motion Control | Yes |
| Integrated Functions / Measuring functions / Measuring time, parameterizable | Yes |
| Integrated Functions / Measuring functions / Dynamic measurement period adjustment | Yes |
| Integrated Functions / Measuring functions / Number of thresholds, parameterizable | 2 |
| Integrated Functions / Measuring functions / Measuring range / Frequency measurement, min. | 0.04 Hz |
| Integrated Functions / Measuring functions / Measuring range / Frequency measurement, max. | 400 kHz; with quadruple evaluation |
| Integrated Functions / Measuring functions / Measuring range / Cycle duration measurement, min. | 2.5 µs |
| Integrated Functions / Measuring functions / Measuring range / Cycle duration measurement, max. | 25 s |
| Integrated Functions / Measuring functions / Accuracy / Frequency measurement | 100 ppm; depending on measuring interval and signal evaluation |
| Integrated Functions / Measuring functions / Accuracy / Cycle duration measurement | 100 ppm; depending on measuring interval and signal evaluation |
| Integrated Functions / Measuring functions / Accuracy / Velocity measurement | 100 ppm; depending on measuring interval and signal evaluation |
| Potential separation / Potential separation digital inputs / between the channels | No |
| Potential separation / Potential separation digital inputs / between the channels, in groups of | 16 |
| Potential separation / Potential separation digital outputs / between the channels | No |
| Potential separation / Potential separation digital outputs / between the channels, in groups of | 16 |
| Potential separation / Potential separation channels / between the channels and backplane bus | Yes |
| Напряжение питания | No |
| Сертификация | Yes |
| Сертификация | Yes |
| Сертификация | 145 kg |
| Сертификация | 60.1 kg |
| Сертификация | 90.4 kg |
| Security / signed firmware update | Yes |
| Security / Secure Boot | Yes |
| Security / safely removing data | Yes |
| Ambient conditions / Ambient temperature during storage/transportation / max. | 70 °C |
| Configuration / Programming language / GRAPH | Yes |
| Configuration / Know-how protection / User program protection/password protection | Yes |
| Configuration / Know-how protection / Copy protection | Yes |
| Configuration / Know-how protection / Block protection | Yes |
| Configuration / Access protection / protection of confidential configuration data | Yes |
| Configuration / Access protection / Password for display | Yes |
| Configuration / Access protection / Protection level: Write protection | Yes |
| Configuration / Access protection / Protection level: Read/write protection | Yes |
| Configuration / Access protection / Protection level: Write protection for Failsafe | No |
| Configuration / Access protection / Protection level: Complete protection | Yes |
| Configuration / Access protection / User administration | Yes; device-wide and centralized |
| Configuration / Access protection / Number of users | 100 |
| Configuration / Access protection / Number of groups | 100 |
| Configuration / Access protection / Number of roles | 50 |
| Configuration / Cycle time monitoring / lower limit | adjustable minimum cycle time |
| Configuration / Cycle time monitoring / upper limit | adjustable maximum cycle time |
| Dimensions / Width | 110 mm |
| Dimensions / Height | 147 mm |
| Dimensions / Depth | 129 mm |