| Data sheet designation | SIMATIC S7-1500, CPU Bundle consisting of: CPU 1518-4 PN/DP MFP (6ES7518- 4AX00-1AB0), including C/C++ Runtime and OPC UA Runtime license, 6 MB work memory for program and 60 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFINET basic services, 4th interface: PROFIBUS, 1 ns bit performance, SIMATIC Memory Card (min. 2 GB) required |
|---|---|
| General information / Product type designation | CPU 1518-4 PN/DP MFP |
| General information / HW functional status | FS04 |
| General information / Firmware version | V3.0 |
| Configuration control / via dataset | Yes |
| Display / Screen diagonal [cm] | 6.1 cm |
| Control elements / Number of keys | 6 |
| Control elements / Mode selector switch | 1 |
| Напряжение питания | 24 V |
| Напряжение питания | 19.2 V |
| Напряжение питания | 28.8 V |
| Напряжение питания | Yes |
| Напряжение питания | 5 ms |
| Напряжение питания | 1/s |
| Input current / Current consumption (rated value) | 1.7 A |
| Input current / Current consumption, max. | 2 A |
| Input current / Inrush current, max. | 2 A; Rated value |
| Power / Infeed power to the backplane bus | 12 W |
| Power / Power consumption from the backplane bus (balanced) | 35 W |
| Power loss / Power loss, typ. | 29 W |
| Storage / Number of slots for SIMATIC memory card | 1 |
| Storage / SIMATIC memory card required | Yes |
| Storage / Work memory / integrated (for program) | 6 Mbyte |
| Storage / Working memory for additional functions / available (for Linux runtime application) | 1 Gbyte |
| Storage / Load memory / Plug-in (SIMATIC Memory Card), max. | 32 Gbyte; the memory card must have at least 2 GB of space on it |
| Storage / Backup / maintenance-free | Yes |
| CPU processing times / for bit operations, typ. | 1 ns |
| CPU processing times / for word operations, typ. | 2 ns |
| CPU processing times / for fixed point arithmetic, typ. | 2 ns |
| CPU processing times / for floating point arithmetic, typ. | 6 ns |
| CPU-blocks / Number of elements (total) | 20 000; Blocks (OB, FB, FC, DB) and UDTs |
| CPU-blocks / Nesting depth / per priority class | 24 |
| Counters, timers and their retentivity / S7 counter / Number | 2 048 |
| Counters, timers and their retentivity / S7 counter / Retentivity / adjustable | Yes |
| Counters, timers and their retentivity / IEC counter / Number | Any (only limited by the main memory) |
| Counters, timers and their retentivity / IEC counter / Retentivity / adjustable | Yes |
| Counters, timers and their retentivity / S7 timer / Number | 2 048 |
| Data areas and their retentivity / Flag / Size, max. | 16 kbyte |
| Data areas and their retentivity / Flag / Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Data areas and their retentivity / Data blocks / Retentivity adjustable | Yes |
| Data areas and their retentivity / Data blocks / Retentivity preset | No |
| Data areas and their retentivity / Local data / per priority class, max. | 64 kbyte; max. 16 KB per block |
| Address area / Number of IO modules | 16 384; max. number of modules / submodules |
| Address area / I/O address area / Inputs | 32 kbyte; All inputs are in the process image |
| Address area / I/O address area / Outputs | 32 kbyte; All outputs are in the process image |
| Address area / I/O address area / per integrated IO subsystem / Inputs (volume) | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 |
| Address area / I/O address area / per integrated IO subsystem / Outputs (volume) | 32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4 |
| Address area / I/O address area / per CM/CP / Inputs (volume) | 8 kbyte |
| Address area / I/O address area / per CM/CP / Outputs (volume) | 8 kbyte |
| Address area / Subprocess images / Number of subprocess images, max. | 32 |
| Hardware configuration / Rack / Number of lines, max. | 1 |
| Time of day / Clock / Type | Hardware clock |
| Time of day / Clock / Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Time of day / Clock / Deviation per day, max. | 10 s; Typ.: 2 s |
| Time of day / Operating hours counter / Number | 16 |
| Time of day / Clock synchronization / supported | Yes |
| Time of day / Clock synchronization / to DP, master | Yes |
| Time of day / Clock synchronization / in AS, master | Yes |
| Time of day / Clock synchronization / in AS, device | Yes |
| Time of day / Clock synchronization / on Ethernet via NTP | Yes |
| Interfaces / Number of PROFINET interfaces | 3 |
| Interfaces / Number of PROFIBUS interfaces | 1 |
| 1. Interface / Interface types / RJ 45 (Ethernet) | Yes; X1 |
| 1. Interface / Interface types / Number of ports | 2 |
| 1. Interface / Interface types / integrated switch | Yes |
| 1. Interface / Protocols / IP protocol | Yes; IPv4 |
| 1. Interface / Protocols / PROFINET IO Controller | Yes |
| 1. Interface / Protocols / PROFINET IO device | Yes |
| 1. Interface / Protocols / SIMATIC communication | Yes |
| 1. Interface / Protocols / Open IE communication | Yes; Optionally also encrypted |
| 1. Interface / Services / Isochronous mode | Yes |
| 1. Interface / Services / Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| 1. Interface / Services / Dynamic Frame Packing (DFP) | Yes |
| 1. Interface / Services / PROFIenergy | Yes; per user program |
| 1. Interface / Services / of which in line, max. | 512 |
| 1. Interface / Services / Number of IO Devices that can be simultaneously | 8; in total across all interfaces |
| 1. Interface / Update time for IRT / for send cycle of 187.5 µs | 187.5 µs |
| 1. Interface / Update time for IRT / for send cycle of 250 µs | 250 µs to 4 ms |
| 1. Interface / Update time for IRT / for send cycle of 500 µs | 500 µs to 8 ms |
| 1. Interface / Update time for IRT / for send cycle of 1 ms | 1 ms to 16 ms |
| 1. Interface / Update time for IRT / for send cycle of 2 ms | 2 ms to 32 ms |
| 1. Interface / Update time for RT / for send cycle of 500 µs | 500 µs to 256 ms |
| 1. Interface / Update time for RT / for send cycle of 1 ms | 1 ms to 512 ms |
| 1. Interface / Services / Isochronous mode #2 | No |
| 1. Interface / Services / Prioritized startup | Yes |
| 1. Interface / Services / Shared device | Yes |
| 1. Interface / Services / Number of IO Controllers with shared device, max. | 4 |
| 1. Interface / Services / activation/deactivation of I-devices | Yes; per user program |
| 1. Interface / Services / Asset management record | Yes; per user program |
| 2. Interface / Interface types / RJ 45 (Ethernet) | Yes; X2 |
| 2. Interface / Interface types / Number of ports | 1 |
| 2. Interface / Interface types / integrated switch | No |
| 2. Interface / Protocols / IP protocol | Yes; IPv4 |
| 2. Interface / Protocols / PROFINET IO Controller | Yes |
| 2. Interface / Protocols / PROFINET IO Device | Yes |
| 2. Interface / Protocols / SIMATIC communication | Yes |
| 2. Interface / Protocols / Open IE communication | Yes; Optionally also encrypted |
| 2. Interface / Services / Isochronous mode | No |
| 2. Interface / Services / Direct data exchange | No |
| 2. Interface / Services / Dynamic Frame Packing (DFP) | No |
| 2. Interface / Services / PROFIenergy | Yes; per user program |
| 2. Interface / Services / Number of IO Devices that can be simultaneously | 8; in total across all interfaces |
| 2. Interface / Services / IO Devices changing during operation (partner | Yes |
| 2. Interface / Services / Prioritized startup | No |
| 2. Interface / Services / Shared device | Yes |
| 2. Interface / Services / Number of IO Controllers with shared device, max. | 4 |
| 2. Interface / Services / activation/deactivation of I-devices | Yes; per user program |
| 2. Interface / Services / Asset management record | Yes; per user program |
| 3. Interface / Interface types / RJ 45 (Ethernet) | Yes; X3 |
| 3. Interface / Interface types / Number of ports | 1; C/C++ Runtime can also be reached via this port |
| 3. Interface / Interface types / integrated switch | No |
| 3. Interface / Protocols / IP protocol | Yes; IPv4 |
| 3. Interface / Protocols / PROFINET IO Controller | No |
| 3. Interface / Protocols / PROFINET IO device | No |
| 3. Interface / Protocols / SIMATIC communication | Yes |
| 3. Interface / Protocols / Open IE communication | Yes |
| 3. Interface / Protocols / Web server | Yes |
| 4. Interface / Interface types / RS 485 | Yes; X4 |
| 4. Interface / Interface types / Number of ports | 1 |
| 4. Interface / Protocols / PROFIBUS DP master | Yes |
| 4. Interface / Protocols / PROFIBUS DP device | No |
| 4. Interface / Protocols / SIMATIC communication | Yes |
| 4. Interface / PROFIBUS DP master / Services / Equidistance | Yes |
| 4. Interface / PROFIBUS DP master / Services / Isochronous mode | Yes |
| 4. Interface / PROFIBUS DP master / Services / activation/deactivation of DP devices | Yes |
| Interface types / RJ 45 (Ethernet) / 100 Mbps | Yes |
| Interface types / RJ 45 (Ethernet) / 1000 Mbps | Yes; Only possible at the X3 interface of the CPU 1518 |
| Interface types / RJ 45 (Ethernet) / Autonegotiation | Yes |
| Interface types / RJ 45 (Ethernet) / Autocrossing | Yes |
| Interface types / RJ 45 (Ethernet) / Industrial Ethernet status LED | Yes |
| Interface types / RS 485 / Transmission rate, max. | 12 Mbit/s |
| Protocols / PROFIsafe | No |
| Protocols / Number of connections / Number of connections, max. | 384; via integrated interfaces of the CPU and connected CPs / CMs |
| Protocols / Number of connections / Number of connections reserved for ES/HMI/web | 10 |
| Protocols / Number of connections / Number of connections via integrated interfaces | 320 |
| Protocols / Number of connections / Number of S7 routing paths | 64; in total, only 16 S7-Routing connections are supported via PROFIBUS |
| Protocols / Redundancy mode / PROFINET system redundancy (S2) | No |
| Protocols / Redundancy mode / PROFINET system redundancy (R1) | No |
| Protocols / Redundancy mode / H-Sync forwarding | Yes |
| Protocols / Redundancy mode / Media redundancy / Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| Protocols / Redundancy mode / Media redundancy / Number of stations in the ring, max. | 50 |
| Protocols / SIMATIC communication / PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| Protocols / SIMATIC communication / S7 routing | Yes |
| Protocols / SIMATIC communication / Data record routing | Yes |
| Protocols / SIMATIC communication / S7 communication, as server | Yes |
| Protocols / SIMATIC communication / S7 communication, as client | Yes |
| Protocols / SIMATIC communication / User data per job, max. | See online help (S7 communication, user data size) |
| Protocols / Open IE communication / TCP/IP | Yes |
| Protocols / Open IE communication / Data length, max. | 64 kbyte |
| Protocols / Open IE communication / several passive connections per port, supported | Yes |
| Protocols / Open IE communication / ISO-on-TCP (RFC1006) | Yes |
| Protocols / Open IE communication / Data length, max. #2 | 2 kbyte; 1 472 bytes for UDP broadcast |
| Protocols / Open IE communication / UDP multicast | Yes; 128 multicast circuits (of which max. 5 via X1) |
| Protocols / Open IE communication / DHCP | Yes |
| Protocols / Open IE communication / SNMP | Yes; disconnected by default |
| Protocols / Open IE communication / LLDP | Yes |
| Protocols / Open IE communication / Encryption | Yes; Optional |
| Protocols / Web server / HTTP | Yes; Standard and user pages |
| Protocols / Web server / HTTPS | Yes; Standard and user pages |
| Protocols / OPC UA / Runtime license required | Yes; "Large" license required |
| Protocols / OPC UA / OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
| Protocols / OPC UA / Number of nodes of the client interfaces, | 5 000 |
| Protocols / OPC UA / Number of elements for one call of | 100 |
| Protocols / OPC UA / Number of registerable nodes, max. | 5 000 |
| Protocols / OPC UA / Number of registerable method calls of | 100 |
| Protocols / OPC UA / Number of sessions, max. | 64 |
| Protocols / OPC UA / Number of accessible variables, max. | 200 000 |
| Protocols / OPC UA / Number of registerable nodes, max. #2 | 50 000 |
| Protocols / OPC UA / Number of subscriptions per session, max. | 50 |
| Protocols / OPC UA / Sampling interval, min. | 10 ms |
| Protocols / OPC UA / Publishing interval, min. | 10 ms |
| Protocols / OPC UA / Number of server methods, max. | 100 |
| Protocols / OPC UA / Number of inputs/outputs per server method, max. | 20 |
| Protocols / OPC UA / Number of alarms for system diagnostics | 200 |
| Protocols / Further protocols / MODBUS | Yes; MODBUS TCP |
| Isochronous mode / Equidistance | Yes |
| S7 message functions / Number of login stations for message functions, max. | 64 |
| S7 message functions / Number of simultaneously active program alarms / Number of program alarms | 4 000 |
| S7 message functions / Number of simultaneously active program alarms / Number of alarms for system diagnostics | 1 000 |
| S7 message functions / Number of simultaneously active program alarms / Number of alarms for motion technology objects | 480 |
| Test commissioning functions / Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 10 engineering systems |
| Test commissioning functions / Status block | Yes; Up to 16 simultaneously (in total across all ES clients) |
| Test commissioning functions / Single step | No |
| Test commissioning functions / Number of breakpoints | 20 |
| Test commissioning functions / Status/control / Status/control variable | Yes |
| Test commissioning functions / Status/control / Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Test commissioning functions / Status/control / Number of variables, max. / of which status variables, max. | 200; per job |
| Test commissioning functions / Status/control / Number of variables, max. / of which control variables, max. | 200; per job |
| Test commissioning functions / Forcing / Forcing | Yes |
| Test commissioning functions / Forcing / Forcing, variables | Peripheral inputs/outputs |
| Test commissioning functions / Forcing / Number of variables, max. | 200 |
| Test commissioning functions / Diagnostic buffer / present | Yes |
| Test commissioning functions / Diagnostic buffer / Number of entries, max. | 3 200 |
| Test commissioning functions / Diagnostic buffer / of which powerfail-proof | 1 000 |
| Test commissioning functions / Traces / Number of configurable Traces | 8; Up to 512 KB of data per trace are possible |
| Interrupts/diagnostics/status information / Diagnostics indication LED / RUN/STOP LED | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LED | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / MAINT LED | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Connection display LINK TX/RX | Yes |
| Supported technology objects / Required Motion Control resources / per speed-controlled axis | 40 |
| Supported technology objects / Required Motion Control resources / per positioning axis | 80 |
| Supported technology objects / Required Motion Control resources / per synchronous axis | 160 |
| Supported technology objects / Required Motion Control resources / per external encoder | 80 |
| Supported technology objects / Required Motion Control resources / per output cam | 20 |
| Supported technology objects / Required Motion Control resources / per cam track | 160 |
| Supported technology objects / Required Motion Control resources / per probe | 40 |
| Supported technology objects / Positioning axis / Number of positioning axes at motion control cycle | 140 |
| Supported technology objects / Controller / PID_3Step | Yes; PID controller with integrated optimization for valves |
| Supported technology objects / Controller / PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Supported technology objects / Counting and measuring / High-speed counter | Yes |
| Сертификация | Yes |
| Сертификация | 570 kg |
| Сертификация | 96.9 kg |
| Сертификация | 483 kg |
| Ambient conditions / Ambient temperature during storage/transportation / max. | 70 °C |
| Configuration / Programming language / GRAPH | Yes |
| Configuration / Know-how protection / User program protection/password protection | Yes |
| Configuration / Know-how protection / Copy protection | Yes |
| Configuration / Know-how protection / Block protection | Yes |
| Configuration / Access protection / protection of confidential configuration data | Yes |
| Configuration / Access protection / Password for display | Yes |
| Configuration / Access protection / Protection level: Write protection | Yes |
| Configuration / Access protection / Protection level: Read/write protection | Yes |
| Configuration / Access protection / Protection level: Complete protection | Yes |
| Configuration / Cycle time monitoring / lower limit | adjustable minimum cycle time |
| Configuration / Cycle time monitoring / upper limit | adjustable maximum cycle time |
| Configuration / Open Development interfaces / Size of ODK SO file, max. | 9.8 Mbyte |
| Dimensions / Width | 175 mm |
| Dimensions / Height | 147 mm |
| Dimensions / Depth | 129 mm |