ПЛК и системы автоматизации
SI

Siemens AG 6ES7518-4FX00-1AC0

Компонент системы автоматизации Siemens 6ES7518-4FX00-1AC0, серия S7-1500. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.

  • Бренд: Siemens AG
  • Артикул (MPN): 6ES7518-4FX00-1AC0
  • Серия: S7-1500 Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationSIMATIC S7-1500F, CPU Bundle consisting of: CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0), including C/C++ Runtime and OPC UA Runtime license, 9 MB work memory for program and 60 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: PROFINET basic services, 4th interface: PROFIBUS, 1 ns bit performance, SIMATIC Memory Card (min. 2 GB) required
General information / Product type designationCPU 1518F-4 PN/DP MFP
General information / HW functional statusFS04
General information / Firmware versionV3.0
General information / FW update possibleYes
Configuration control / via datasetYes
Display / Screen diagonal [cm]6.1 cm
Control elements / Number of keys6
Control elements / Mode selector switch1
Напряжение питания24 V
Напряжение питания19.2 V
Напряжение питания28.8 V
Напряжение питанияYes
Напряжение питания5 ms
Напряжение питания1/s
Input current / Current consumption (rated value)1.7 A
Input current / Current consumption, max.2 A
Input current / Inrush current, max.2 A; Rated value
Power / Infeed power to the backplane bus12 W
Power / Power consumption from the backplane bus (balanced)35 W
Power loss / Power loss, typ.29 W
Storage / Number of slots for SIMATIC memory card1
Storage / SIMATIC memory card requiredYes
Storage / Work memory / integrated (for program)9 Mbyte
Storage / Working memory for additional functions / available (for Linux runtime application)1 Gbyte
Storage / Load memory / Plug-in (SIMATIC Memory Card), max.32 Gbyte; the memory card must have at least 2 GB of space on it
Storage / Backup / maintenance-freeYes
CPU processing times / for bit operations, typ.1 ns
CPU processing times / for word operations, typ.2 ns
CPU processing times / for fixed point arithmetic, typ.2 ns
CPU processing times / for floating point arithmetic, typ.6 ns
CPU-blocks / Number of elements (total)20 000; Blocks (OB, FB, FC, DB) and UDTs
CPU-blocks / Nesting depth / per priority class24
Counters, timers and their retentivity / S7 counter / Number2 048
Counters, timers and their retentivity / S7 counter / Retentivity / adjustableYes
Counters, timers and their retentivity / IEC counter / NumberAny (only limited by the main memory)
Counters, timers and their retentivity / IEC counter / Retentivity / adjustableYes
Counters, timers and their retentivity / S7 timer / Number2 048
Counters, timers and their retentivity / S7 timer / Retentivity / adjustableYes
Counters, timers and their retentivity / IEC timer / NumberAny (only limited by the main memory)
Counters, timers and their retentivity / IEC timer / Retentivity / can be setYes
Data areas and their retentivity / Flag / Size, max.16 kbyte
Data areas and their retentivity / Flag / Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data areas and their retentivity / Data blocks / Retentivity adjustableYes
Data areas and their retentivity / Data blocks / Retentivity presetNo
Data areas and their retentivity / Local data / per priority class, max.64 kbyte; max. 16 KB per block
Address area / Number of IO modules16 384; max. number of modules / submodules
Address area / I/O address area / Inputs32 kbyte; All inputs are in the process image
Address area / I/O address area / Outputs32 kbyte; All outputs are in the process image
Address area / I/O address area / per integrated IO subsystem / Inputs (volume)32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
Address area / I/O address area / per integrated IO subsystem / Outputs (volume)32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
Address area / I/O address area / per CM/CP / Inputs (volume)8 kbyte
Address area / I/O address area / per CM/CP / Outputs (volume)8 kbyte
Address area / Subprocess images / Number of subprocess images, max.32
Hardware configuration / Rack / Number of lines, max.1
Time of day / Clock / TypeHardware clock
Time of day / Clock / Backup time6 wk; At 40 °C ambient temperature, typically
Time of day / Clock / Deviation per day, max.10 s; Typ.: 2 s
Time of day / Operating hours counter / Number16
Time of day / Clock synchronization / supportedYes
Time of day / Clock synchronization / to DP, masterYes
Time of day / Clock synchronization / in AS, masterYes
Time of day / Clock synchronization / in AS, deviceYes
Time of day / Clock synchronization / on Ethernet via NTPYes
Interfaces / Number of PROFINET interfaces3
Interfaces / Number of PROFIBUS interfaces1
1. Interface / Interface types / RJ 45 (Ethernet)Yes; X1
1. Interface / Interface types / Number of ports2
1. Interface / Interface types / integrated switchYes
1. Interface / Protocols / IP protocolYes; IPv4
1. Interface / Protocols / PROFINET IO ControllerYes
1. Interface / Protocols / PROFINET IO deviceYes
1. Interface / Protocols / SIMATIC communicationYes
1. Interface / Protocols / Open IE communicationYes; Optionally also encrypted
1. Interface / Services / Isochronous modeYes
1. Interface / Services / Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
1. Interface / Services / Dynamic Frame Packing (DFP)Yes
1. Interface / Services / PROFIenergyYes; per user program
1. Interface / Services / of which in line, max.512
1. Interface / Services / Number of IO Devices that can be simultaneously8; in total across all interfaces
1. Interface / Update time for IRT / for send cycle of 187.5 µs187.5 µs
1. Interface / Update time for IRT / for send cycle of 250 µs250 µs to 4 ms
1. Interface / Update time for IRT / for send cycle of 500 µs500 µs to 8 ms
1. Interface / Update time for IRT / for send cycle of 1 ms1 ms to 16 ms
1. Interface / Update time for IRT / for send cycle of 2 ms2 ms to 32 ms
1. Interface / Update time for RT / for send cycle of 500 µs500 µs to 256 ms
1. Interface / Update time for RT / for send cycle of 1 ms1 ms to 512 ms
1. Interface / Services / Isochronous mode #2No
1. Interface / Services / Prioritized startupYes
1. Interface / Services / Shared deviceYes
1. Interface / Services / Number of IO Controllers with shared device, max.4
1. Interface / Services / activation/deactivation of I-devicesYes; per user program
1. Interface / Services / Asset management recordYes; per user program
2. Interface / Interface types / RJ 45 (Ethernet)Yes; X2
2. Interface / Interface types / Number of ports1
2. Interface / Interface types / integrated switchNo
2. Interface / Protocols / IP protocolYes; IPv4
2. Interface / Protocols / PROFINET IO ControllerYes
2. Interface / Protocols / PROFINET IO DeviceYes
2. Interface / Protocols / SIMATIC communicationYes
2. Interface / Protocols / Open IE communicationYes; Optionally also encrypted
2. Interface / Services / Isochronous modeNo
2. Interface / Services / Direct data exchangeNo
2. Interface / Services / Dynamic Frame Packing (DFP)No
2. Interface / Services / PROFIenergyYes; per user program
2. Interface / Services / Number of IO Devices that can be simultaneously8; in total across all interfaces
2. Interface / Services / IO Devices changing during operation (partnerYes
2. Interface / Services / Prioritized startupNo
2. Interface / Services / Shared deviceYes
2. Interface / Services / Number of IO Controllers with shared device, max.4
2. Interface / Services / activation/deactivation of I-devicesYes; per user program
2. Interface / Services / Asset management recordYes; per user program
3. Interface / Interface types / RJ 45 (Ethernet)Yes; X3
3. Interface / Interface types / Number of ports1; C/C++ Runtime can also be reached via this port
3. Interface / Interface types / integrated switchNo
3. Interface / Protocols / IP protocolYes; IPv4
3. Interface / Protocols / PROFINET IO ControllerNo
3. Interface / Protocols / PROFINET IO deviceNo
3. Interface / Protocols / SIMATIC communicationYes
3. Interface / Protocols / Open IE communicationYes; Optionally also encrypted
3. Interface / Protocols / Web serverYes
4. Interface / Interface types / RS 485Yes; X4
4. Interface / Interface types / Number of ports1
4. Interface / Protocols / PROFIBUS DP masterYes
4. Interface / Protocols / PROFIBUS DP deviceNo
4. Interface / Protocols / SIMATIC communicationYes
4. Interface / PROFIBUS DP master / Services / EquidistanceYes
4. Interface / PROFIBUS DP master / Services / Isochronous modeYes
4. Interface / PROFIBUS DP master / Services / activation/deactivation of DP devicesYes
Interface types / RJ 45 (Ethernet) / 100 MbpsYes
Interface types / RJ 45 (Ethernet) / 1000 MbpsYes; Only possible at the X3 interface of the CPU 1518
Interface types / RJ 45 (Ethernet) / AutonegotiationYes
Interface types / RJ 45 (Ethernet) / AutocrossingYes
Interface types / RJ 45 (Ethernet) / Industrial Ethernet status LEDYes
Interface types / RS 485 / Transmission rate, max.12 Mbit/s
Protocols / PROFIsafeYes; V2.4 / V2.6
Protocols / Number of connections / Number of connections, max.384; via integrated interfaces of the CPU and connected CPs / CMs
Protocols / Number of connections / Number of connections reserved for ES/HMI/web10
Protocols / Number of connections / Number of connections via integrated interfaces320
Protocols / Number of connections / Number of S7 routing paths64; in total, only 16 S7-Routing connections are supported via PROFIBUS
Protocols / Redundancy mode / PROFINET system redundancy (S2)No
Protocols / Redundancy mode / PROFINET system redundancy (R1)No
Protocols / Redundancy mode / H-Sync forwardingYes
Protocols / Redundancy mode / Media redundancy / Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
Protocols / Redundancy mode / Media redundancy / Number of stations in the ring, max.50
Protocols / SIMATIC communication / PG/OP communicationYes; encryption with TLS V1.3 pre-selected
Protocols / SIMATIC communication / S7 routingYes
Protocols / SIMATIC communication / Data record routingYes
Protocols / SIMATIC communication / S7 communication, as serverYes
Protocols / SIMATIC communication / S7 communication, as clientYes
Protocols / SIMATIC communication / User data per job, max.See online help (S7 communication, user data size)
Protocols / Open IE communication / TCP/IPYes
Protocols / Open IE communication / Data length, max.64 kbyte
Protocols / Open IE communication / several passive connections per port, supportedYes
Protocols / Open IE communication / ISO-on-TCP (RFC1006)Yes
Protocols / Open IE communication / Data length, max. #22 kbyte; 1 472 bytes for UDP broadcast
Protocols / Open IE communication / UDP multicastYes; 128 multicast circuits (of which max. 5 via X1)
Protocols / Open IE communication / DHCPYes
Protocols / Open IE communication / SNMPYes; disconnected by default
Protocols / Open IE communication / LLDPYes
Protocols / Open IE communication / EncryptionYes; Optional
Protocols / Web server / HTTPYes; Standard and user pages
Protocols / Web server / HTTPSYes; Standard and user pages
Protocols / OPC UA / Runtime license requiredYes; "Large" license required
Protocols / OPC UA / OPC UA ClientYes; Data Access (registered Read/Write), Method Call
Protocols / OPC UA / Number of nodes of the client interfaces,5 000
Protocols / OPC UA / Number of elements for one call of100
Protocols / OPC UA / Number of registerable nodes, max.5 000
Protocols / OPC UA / Number of registerable method calls of100
Protocols / OPC UA / Number of sessions, max.64
Protocols / OPC UA / Number of accessible variables, max.200 000
Protocols / OPC UA / Number of registerable nodes, max. #250 000
Protocols / OPC UA / Number of subscriptions per session, max.50
Protocols / OPC UA / Sampling interval, min.10 ms
Protocols / OPC UA / Publishing interval, min.10 ms
Protocols / OPC UA / Number of server methods, max.100
Protocols / OPC UA / Number of inputs/outputs per server method, max.20
Protocols / OPC UA / Number of alarms for system diagnostics200
Protocols / Further protocols / MODBUSYes; MODBUS TCP
Isochronous mode / EquidistanceYes
S7 message functions / Number of login stations for message functions, max.64
S7 message functions / Number of simultaneously active program alarms / Number of program alarms4 000
S7 message functions / Number of simultaneously active program alarms / Number of alarms for system diagnostics1 000
S7 message functions / Number of simultaneously active program alarms / Number of alarms for motion technology objects480
Test commissioning functions / Joint commission (Team Engineering)Yes; Parallel online access possible for up to 10 engineering systems
Test commissioning functions / Status blockYes; Up to 16 simultaneously (in total across all ES clients)
Test commissioning functions / Single stepNo
Test commissioning functions / Number of breakpoints20
Test commissioning functions / Status/control / Status/control variableYes
Test commissioning functions / Status/control / VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Test commissioning functions / Status/control / Number of variables, max. / of which status variables, max.200; per job
Test commissioning functions / Status/control / Number of variables, max. / of which control variables, max.200; per job
Test commissioning functions / Forcing / ForcingYes
Test commissioning functions / Forcing / Forcing, variablesperipheral inputs/outputs (without fail-safe)
Test commissioning functions / Forcing / Number of variables, max.200
Test commissioning functions / Diagnostic buffer / presentYes
Test commissioning functions / Diagnostic buffer / Number of entries, max.3 200
Test commissioning functions / Diagnostic buffer / of which powerfail-proof1 000
Test commissioning functions / Traces / Number of configurable Traces8; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information / Diagnostics indication LED / RUN/STOP LEDYes
Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LEDYes
Interrupts/diagnostics/status information / Diagnostics indication LED / MAINT LEDYes
Interrupts/diagnostics/status information / Diagnostics indication LED / Connection display LINK TX/RXYes
Supported technology objects / Required Motion Control resources / per speed-controlled axis40
Supported technology objects / Required Motion Control resources / per positioning axis80
Supported technology objects / Required Motion Control resources / per synchronous axis160
Supported technology objects / Required Motion Control resources / per external encoder80
Supported technology objects / Required Motion Control resources / per output cam20
Supported technology objects / Required Motion Control resources / per cam track160
Supported technology objects / Required Motion Control resources / per probe40
Supported technology objects / Positioning axis / Number of positioning axes at motion control cycle140
Supported technology objects / Controller / PID_3StepYes; PID controller with integrated optimization for valves
Supported technology objects / Controller / PID-TempYes; PID controller with integrated optimization for temperature
Supported technology objects / Counting and measuring / High-speed counterYes
СертификацияYes
Сертификация570 kg
Сертификация96.9 kg
Сертификация483 kg
СертификацияSIL 3
Сертификацияof 100 hours)
Сертификация< 2.00E-05
Ambient conditions / Ambient temperature during storage/transportation / max.70 °C
Configuration / Programming language / GRAPHYes
Configuration / Know-how protection / User program protection/password protectionYes
Configuration / Know-how protection / Copy protectionYes
Configuration / Know-how protection / Block protectionYes
Configuration / Access protection / protection of confidential configuration dataYes
Configuration / Access protection / Password for displayYes
Configuration / Access protection / Protection level: Write protectionYes
Configuration / Access protection / Protection level: Read/write protectionYes
Configuration / Access protection / Protection level: Complete protectionYes
Configuration / Cycle time monitoring / lower limitadjustable minimum cycle time
Configuration / Cycle time monitoring / upper limitadjustable maximum cycle time
Configuration / Open Development interfaces / Size of ODK SO file, max.9.8 Mbyte
Dimensions / Width175 mm
Dimensions / Height147 mm
Dimensions / Depth129 mm
Получить предложение по этой позиции