| Data sheet designation | SIMATIC S7-1500, digital output module, DQ 8x24 V DC/5 A AUX, width 35 mm, 8 channels in groups of 4, 5 A / channel, 8 A / group, per group, two channels can be parallel-switched (2 x 8 A), 8 channels with pulse width modulation (PWM; max 12.5 kHz), front connector (screw terminal or push-in) to be ordered separately |
|---|---|
| General information / Product type designation | DQ 8x24VDC/5A HS |
| General information / HW functional status | from FS01 |
| General information / Firmware version | from V1.0.0 |
| General information / FW update possible | Yes |
| General information / Product function / I&M data | Yes; I&M0 to I&M3 |
| General information / Product function / Isochronous mode | Yes |
| General information / Product function / Prioritized startup | Yes |
| General information / Engineering with / STEP 7 TIA Portal configurable/integrated from version | V18 with HSP 0434 / V20 |
| General information / Engineering with / STEP 7 configurable/integrated from version | STEP 7 V5.7 or higher SP1 or higher |
| General information / Engineering with / PROFIBUS from GSD version/GSD revision | revision 3 / version 5.1 |
| General information / Engineering with / PROFINET from GSD version/GSD revision | V 2.43 / - |
| General information / Operating mode / DQ with energy-saving function | Yes; Valve control |
| General information / Operating mode / Cam control (switching at comparison values) | No |
| General information / Operating mode / Oversampling | Yes |
| General information / Operating mode / Integrated operating cycle counter | Yes |
| Напряжение питания | 24 V |
| Напряжение питания | 19.2 V |
| Напряжение питания | 28.8 V |
| Напряжение питания | Yes; through internal protection with 10 A per group |
| Input current / Current consumption, max. | 40 mA; 20 mA per group, no output is activated. |
| Напряжение питания | 24 V |
| Power / Power consumption from the backplane bus | 0.55 W |
| Power loss / Power loss, typ. | 2.4 W |
| Address area / Address space per module / Inputs | 0 byte; typical, maximum 7 bytes, see manual for details |
| Address area / Address space per module / Outputs | 1 byte; typical, maximum 18 bytes, see manual for details |
| Digital outputs / Type of digital output | Transistor |
| Digital outputs / Number of digital outputs | 8 |
| Digital outputs / Current-sinking | No |
| Digital outputs / Current-sourcing | Yes; Push-pull output |
| Digital outputs / Digital outputs, parameterizable | Yes |
| Digital outputs / Short-circuit protection | Yes |
| Digital outputs / Response threshold, typ. | 10 A; 4 us response time |
| Digital outputs / Open-circuit detection | No |
| Digital outputs / Overload protection | Thermal overload protection |
| Напряжение питания | M (-1 V) |
| Digital outputs / Controlling a digital input | Yes |
| Digital outputs / Digital output functions, parameterizable / Switching tripped by comparison values | No |
| Digital outputs / Digital output functions, parameterizable / Freely usable digital output | Yes |
| Digital outputs / Digital output functions, parameterizable / PWM output | Yes |
| Digital outputs / Digital output functions, parameterizable / Number, max. | 8 |
| Digital outputs / Digital output functions, parameterizable / Cycle duration, parameterizable | Yes; 0.08 ... 100 ms |
| Digital outputs / Digital output functions, parameterizable / ON period, min. | 0 % |
| Digital outputs / Digital output functions, parameterizable / ON period, max. | 100 % |
| Digital outputs / Digital output functions, parameterizable / Resolution of the duty cycle | 0.1 % |
| Digital outputs / Digital output functions, parameterizable / Minimum pulse duration | 30 µs |
| Digital outputs / Digital output functions, parameterizable / Digital output with oversampling | Yes |
| Digital outputs / Digital output functions, parameterizable / Values per cycle, max. | 16 |
| Digital outputs / Switching capacity of the outputs / with resistive load, max. | 5 A |
| Digital outputs / Switching capacity of the outputs / with inductive load, max. | 5 A |
| Digital outputs / Switching capacity of the outputs / on lamp load, max. | 10 W |
| Digital outputs / Load resistance range / lower limit | 4.8 Ω |
| Digital outputs / Load resistance range / upper limit | 4 kΩ |
| Напряжение питания | L+ (-0.8 V) |
| Digital outputs / Output current / for signal "1" rated value | 5 A |
| Digital outputs / Output current / for signal "1" permissible range, max. | 6 A; note derating data in the manual |
| Digital outputs / Output current / for signal "0" residual current, max. | 0.5 mA |
| Digital outputs / Output delay with resistive load / "0" to "1", typ. | 3 µs |
| Digital outputs / Output delay with resistive load / "1" to "0", typ. | 3 µs |
| Digital outputs / Parallel switching of two outputs / for logic links | No |
| Digital outputs / Parallel switching of two outputs / for uprating | Yes; 8A for parallel connection of channel 0 and 1 / channel 4 and 5 |
| Digital outputs / Parallel switching of two outputs / for redundant control of a load | No |
| Digital outputs / Switching frequency / with resistive load, max. | 12.5 kHz |
| Digital outputs / Switching frequency / with inductive load, max. | 12.5 kHz; According to IEC 60947-5-1, DC-13 |
| Digital outputs / Switching frequency / on lamp load, max. | 12.5 kHz |
| Digital outputs / Total current of the outputs / Current per channel, max. | 5 A; see additional description in the manual |
| Digital outputs / horizontal installation / up to 60 °C, max. | 5 A |
| Digital outputs / vertical installation / up to 40 °C, max. | 5 A |
| Digital outputs / Cable length / shielded, max. | 1 000 m |
| Digital outputs / Cable length / unshielded, max. | 600 m |
| Isochronous mode / Bus cycle time (TDP), min. | 250 µs |
| Interrupts/diagnostics/status information / Diagnostics function | Yes |
| Interrupts/diagnostics/status information / Substitute values connectable | Yes |
| Interrupts/diagnostics/status information / Alarms / Diagnostic alarm | Yes |
| Interrupts/diagnostics/status information / Alarms / Maintenance interrupt | Yes; maintenance alarm for switching cycle counter |
| Напряжение питания | Yes |
| Interrupts/diagnostics/status information / Diagnoses / Wire break | No |
| Interrupts/diagnostics/status information / Diagnoses / short-circuit | Yes |
| Interrupts/diagnostics/status information / Diagnoses / Group error | Yes |
| Interrupts/diagnostics/status information / Diagnostics indication LED / RUN LED | Yes; green LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LED | Yes; red LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / MAINT LED | Yes; Yellow LED |
| Напряжение питания | Yes; green LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / Channel status display | Yes; green LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / for channel diagnostics | Yes; red LED |
| Interrupts/diagnostics/status information / Diagnostics indication LED / for module diagnostics | Yes; red LED |
| Potential separation / Potential separation channels / between the channels | No |
| Potential separation / Potential separation channels / between the channels, in groups of | 4 |
| Potential separation / Potential separation channels / between the channels and backplane bus | Yes |
| Isolation / Isolation tested with | 707 V DC (type test) |
| Сертификация | Siemens EcoTech |
| Сертификация | No |
| Сертификация | No |
| Сертификация | Yes |
| Сертификация | 43.8 kg |
| Сертификация | 9.5 kg |
| Сертификация | 34.5 kg |
| Security / safely removing data | No |
| Security / data integrity | Yes; Firmware V3.0.0 or higher |
| Рабочая температура | -30 °C |
| Рабочая температура | 60 °C |
| Рабочая температура | -30 °C |
| Рабочая температура | 40 °C |
| Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Ambient conditions / Absolute humidity / dew point, min. | -60 °C; suitable for dry room applications |
| Dimensions / Width | 35 mm |
| Dimensions / Height | 147 mm |
| Dimensions / Depth | 129 mm |