Siemens AG 6ES7531-7QF00-0AB0

Модуль ввода-вывода Siemens 6ES7531-7QF00-0AB0, серия S7-1500. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.

  • Бренд: Siemens AG
  • Артикул (MPN): 6ES7531-7QF00-0AB0
  • Серия: S7-1500 Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationSIMATIC S7-1500 Analog input module, AI 8xU/I/R/RTD BA, 16 bit resolution, Accuracy 0.5%, 8 channels in groups of 8; Common mode voltage 4 V DC, Diagnostics; Hardware interrupts; Delivery including infeed element, shield bracket and shield terminal: Front connector (screw terminals or push-in) to be ordered separately
General information / Product type designationAI 8xU/I/R/RTD BA
General information / HW functional statusFS01
General information / Firmware versionV1.0.0
General information / FW update possibleYes
General information / Product function / I&M dataYes; I&M0 to I&M3
General information / Product function / Isochronous modeNo
General information / Product function / Prioritized startupNo
General information / Product function / Measuring range scalableNo
General information / Product function / Scalable measured valuesNo
General information / Product function / Adjustment of measuring rangeNo
General information / Engineering with / STEP 7 TIA Portal configurable/integrated from versionV15.1 / V16
General information / Engineering with / STEP 7 configurable/integrated from versionV5.5 SP3 / -
General information / Engineering with / PROFIBUS from GSD version/GSD revisionV1.0 / V5.1
General information / Engineering with / PROFINET from GSD version/GSD revisionV2.3 / -
General information / Operating mode / OversamplingNo
CiR - Configuration in RUN / Reparameterization possible in RUNYes
CiR - Configuration in RUN / Calibration possible in RUNNo
Input current / Current consumption, max.0 mA; no supply required
Power / Power consumption from the backplane bus0.85 W
Power loss / Power loss, typ.0.9 W
Address area / Address space per module / Inputs16 byte; typical, maximum 68 bytes, see manual for details
Address area / Address space per module / Outputs0 byte
Analog inputs / Number of analog inputs8
Analog inputs / For current measurement8
Напряжение питания8
Analog inputs / Standardization of measured valuesNo
Напряжение питанияNo
Напряжение питанияNo
Напряжение питанияYes
Напряжение питания10 MΩ
Напряжение питанияYes
Напряжение питания10 MΩ
Напряжение питанияYes
Напряжение питания10 MΩ
Напряжение питанияNo
Напряжение питанияNo
Напряжение питанияNo
Напряжение питанияYes
Напряжение питания10 MΩ
Напряжение питанияYes
Напряжение питания10 MΩ
Напряжение питанияYes
Напряжение питания10 MΩ
Напряжение питанияNo
Analog inputs / Input ranges (rated values), currents / 0 to 20 mAYes
Analog inputs / Input ranges (rated values), currents / Input resistance (0 to 20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Analog inputs / Input ranges (rated values), currents / -20 mA to +20 mAYes
Analog inputs / Input ranges (rated values), currents / Input resistance (-20 mA to +20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Analog inputs / Input ranges (rated values), currents / 4 mA to 20 mAYes
Analog inputs / Input ranges (rated values), currents / Input resistance (4 mA to 20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Analog inputs / Input ranges (rated values), thermocouples / Type BNo
Analog inputs / Input ranges (rated values), thermocouples / Type CNo
Analog inputs / Input ranges (rated values), thermocouples / Type ENo
Analog inputs / Input ranges (rated values), thermocouples / Type JNo
Analog inputs / Input ranges (rated values), thermocouples / Type KNo
Analog inputs / Input ranges (rated values), thermocouples / Type LNo
Analog inputs / Input ranges (rated values), thermocouples / Type NNo
Analog inputs / Input ranges (rated values), thermocouples / Type RNo
Analog inputs / Input ranges (rated values), thermocouples / Type SNo
Analog inputs / Input ranges (rated values), thermocouples / Type TNo
Analog inputs / Input ranges (rated values), thermocouples / Type UNo
Analog inputs / Input ranges (rated values), thermocouples / Type TXK/TXK(L) to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Cu 10No
Analog inputs / Input ranges (rated values), resistance thermometer / Cu 10 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Cu 50No
Analog inputs / Input ranges (rated values), resistance thermometer / Cu 50 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Cu 100No
Analog inputs / Input ranges (rated values), resistance thermometer / Cu 100 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 10No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 10 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 100Yes; Standard/climate
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Ni 100)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 100 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 1000Yes; Standard/climate
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Ni 1000)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 1000 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / LG-Ni 1000Yes; Standard/climate
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (LG-Ni 1000)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 120No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 120 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 200No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 200 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 500No
Analog inputs / Input ranges (rated values), resistance thermometer / Ni 500 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 10No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 10 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 50No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 50 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100Yes; Standard/climate
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Pt 100)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 100 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 1000Yes; Standard/climate
Analog inputs / Input ranges (rated values), resistance thermometer / Input resistance (Pt 1000)10 MΩ
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 1000 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 200No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 200 according to GOSTNo
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 500No
Analog inputs / Input ranges (rated values), resistance thermometer / Pt 500 according to GOSTNo
Analog inputs / Input ranges (rated values), resistors / 0 to 150 ohmsNo
Analog inputs / Input ranges (rated values), resistors / 0 to 300 ohmsNo
Analog inputs / Input ranges (rated values), resistors / 0 to 600 ohmsYes
Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 600 ohms)10 MΩ
Analog inputs / Input ranges (rated values), resistors / 0 to 3000 ohmsNo
Analog inputs / Input ranges (rated values), resistors / 0 to 6000 ohmsYes
Analog inputs / Input ranges (rated values), resistors / Input resistance (0 to 6000 ohms)10 MΩ
Analog inputs / Input ranges (rated values), resistors / Input resistance (PTC)10 MΩ
Analog inputs / Cable length / shielded, max.200 m; 50 m at 50 mV
Analog value generation for the inputs / Measurement principleintegrating
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Resolution with overrange (bit including sign), max.16 bit
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time, parameterizableYes
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Integration time (ms)2,5 / 16,67 / 20 / 100 ms
Analog value generation for the inputs / Integration and conversion time/resolution per channel / Basic conversion time, including integration time (ms)10 / 24 / 27 / 107 ms
Analog value generation for the inputs / Smoothing of measured values / parameterizableYes
Analog value generation for the inputs / Smoothing of measured values / Step: NoneYes
Analog value generation for the inputs / Smoothing of measured values / Step: lowYes
Analog value generation for the inputs / Smoothing of measured values / Step: MediumYes
Analog value generation for the inputs / Smoothing of measured values / Step: HighYes
Напряжение питанияYes
Encoder / Connection of signal encoders / for current measurement as 2-wire transducerYes; with external supply
Encoder / Connection of signal encoders / for current measurement as 4-wire transducerYes
Errors/accuracies / Linearity error (relative to input range), (+/-)0.1 %
Errors/accuracies / Temperature error (relative to input range), (+/-)0.006 %/K
Errors/accuracies / Operational error limit in overall temperature range / Current, relative to input range, (+/-)0.5 %
Errors/accuracies / Basic error limit (operational limit at 25 °C) / Current, relative to input range, (+/-)0.3 %
Напряжение питания4 V
Errors/accuracies / Common mode interference, min.60 dB
Interrupts/diagnostics/status information / Diagnostics functionYes
Interrupts/diagnostics/status information / Alarms / Diagnostic alarmYes
Interrupts/diagnostics/status information / Alarms / Limit value alarmYes; two upper and two lower limit values in each case
Напряжение питанияNo
Interrupts/diagnostics/status information / Diagnoses / Wire breakYes; Only for 1 ... 5 V, 4 ... 20 mA, R, and RTD
Interrupts/diagnostics/status information / Diagnoses / Short-circuitNo
Interrupts/diagnostics/status information / Diagnoses / Group errorNo
Interrupts/diagnostics/status information / Diagnoses / Overflow/UnderflowYes
Interrupts/diagnostics/status information / Diagnostics indication LED / RUN LEDYes; green LED
Interrupts/diagnostics/status information / Diagnostics indication LED / ERROR LEDYes; red LED
Interrupts/diagnostics/status information / Diagnostics indication LED / MAINT LEDNo
Напряжение питанияNo
Interrupts/diagnostics/status information / Diagnostics indication LED / Channel status displayYes; green LED
Interrupts/diagnostics/status information / Diagnostics indication LED / for channel diagnosticsYes; red LED
Interrupts/diagnostics/status information / Diagnostics indication LED / for module diagnosticsYes; red LED
Potential separation / Potential separation channels / between the channelsNo
Potential separation / Potential separation channels / between the channels, in groups of8
Potential separation / Potential separation channels / between the channels and backplane busYes
Permissible potential difference / between the inputs (UCM)8 V DC
Permissible potential difference / Between the inputs and MANA (UCM)4 V DC
Isolation / Isolation tested with707 V DC (type test)
СертификацияSiemens EcoTech
СертификацияNo
СертификацияNo
СертификацияYes
Сертификация38.6 kg
Сертификация14.4 kg
Сертификация24.6 kg
Security / securely removing dataNo
Security / data integrityNo
Рабочая температура-30 °C; From FS05
Рабочая температура60 °C
Рабочая температура-30 °C; From FS05
Рабочая температура40 °C
Ambient conditions / Altitude during operation relating to sea level / Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Ambient conditions / Absolute humidity / dew point, min.-60 °C; suitable for dry room applications
Dimensions / Width35 mm
Dimensions / Height147 mm
Dimensions / Depth129 mm
Масса250 g
Получить предложение по этой позиции