Siemens AG 6GK5202-2BH00-2BD2
SCALANCE XF-200IRT managed
Категории:
Технические характеристики
| product type designation – product brand name | SCALANCE |
|---|---|
| product type designation – product type designation | XF202-2P IRT |
| product type designation – Technical Product Detail Page | https://i.siemens.com/1P6GK5202-2BH00-2BD2 |
| transfer rate – transfer rate | 10, 100 Mbit/s |
| interfaces / for communication / integrated – ● for network components or terminal equipment | 2 |
| interfaces / for communication / integrated – number of 100 Mbit/s SC-RJ-ports / for POF FOC / with push-pull connection system | 2 |
| interfaces / other – ● for signaling contact | 1 |
| interfaces / other – ● for power supply | 1 |
| interfaces / other – ● for signaling contact (2) | 2-pole terminal block |
| interfaces / other – ● for power supply (2) | 2-pole terminal block |
| interfaces / other – ● C-PLUG | Yes |
| interfaces / other – ● at DC / rated value | 24 V |
| interfaces / other – ● at DC / maximum | 0.1 A |
| Напряжение питания | DC |
| Напряжение питания | 24 V |
| Напряжение питания | 7.2 W |
| Напряжение питания | 19.2 ... 28.8 |
| Напряжение питания | 0.4 A |
| Напряжение питания | 2-pole terminal block |
| Напряжение питания | Yes |
| Напряжение питания | 2.5 A (cannot be replaced by user) |
| ambient conditions – ● during operation | 0 ... 50 °C |
| ambient conditions – ● during storage | -40 ... +70 °C |
| ambient conditions – ● during transport | -40 ... +70 °C |
| ambient conditions – ● at 25 °C / without condensation / during operation / maximum | 95 % |
| ambient conditions – protection class IP | IP20 |
| Масса | compact |
| Масса | 100 mm |
| Масса | 117 mm |
| Масса | 74 mm |
| Масса | 0.25 kg |
| Масса | Yes |
| Масса | No |
| Масса | No |
| Масса | No |
| product features, product functions, product components / general – cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s | 50 |
| product features, product functions, product components / general – cascading in cases of star topology | any (depending only on signal propagation time) |
| product functions / management, configuration, engineering – ● CLI | Yes |
| product functions / management, configuration, engineering – ● web-based management | Yes |
| product functions / management, configuration, engineering – ● MIB support | Yes |
| product functions / management, configuration, engineering – ● TRAPs via email | Yes |
| product functions / management, configuration, engineering – ● configuration with STEP 7 | Yes |
| product functions / management, configuration, engineering – ● port mirroring | No |
| product functions / management, configuration, engineering – ● multiport mirroring | No |
| product functions / management, configuration, engineering – ● with IRT / PROFINET IO switch | Yes |
| product functions / management, configuration, engineering – ● PROFINET IO diagnosis | Yes |
| product functions / management, configuration, engineering – ● switch-managed | Yes |
| product functions / management, configuration, engineering – PROFINET conformity class | C |
| product functions / management, configuration, engineering – ● Telnet | Yes |
| product functions / management, configuration, engineering – ● HTTP | Yes |
| product functions / management, configuration, engineering – ● HTTPS | Yes |
| product functions / management, configuration, engineering – ● TFTP | Yes |
| product functions / management, configuration, engineering – ● FTP | Yes |
| product functions / management, configuration, engineering – ● BOOTP | No |
| product functions / management, configuration, engineering – ● DCP | Yes |
| product functions / management, configuration, engineering – ● LLDP | Yes |
| product functions / management, configuration, engineering – ● SNMP v1 | Yes |
| product functions / management, configuration, engineering – ● SNMP v2 | Yes |
| product functions / management, configuration, engineering – ● SNMP v3 | Yes |
| product functions / management, configuration, engineering – ● I&M0 - device-specific information | Yes |
| product functions / management, configuration, engineering – ● I&M1 - higher level designation/location designation | Yes |
| product functions / diagnostics – ● port diagnostics | Yes |
| product functions / diagnostics – ● statistics Packet Size | Yes |
| product functions / diagnostics – ● statistics packet type | Yes |
| product functions / diagnostics – ● error statistics | Yes |
| product functions / DHCP – ● DHCP client | Yes |
| product functions / redundancy – protocol / is supported / Media Redundancy Protocol (MRP) | Yes |
| product functions / redundancy – ● media redundancy protocol (MRP) with redundancy manager | Yes |
| product functions / redundancy – ● Media Redundancy Protocol for Planned Duplication (MRPD) | Yes |
| product functions / redundancy – ● ring redundancy | Yes |
| product functions / redundancy – ● high speed redundancy protocol (HRP) with redundancy manager | Yes |
| product functions / redundancy – ● high speed redundancy protocol (HRP) with standby redundancy | Yes |
| product functions / redundancy – ● Parallel Redundancy Protocol (PRP)/operation in the PRP-network | Yes |
| product functions / redundancy – ● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA) | No |
| product functions / redundancy – ● passive listening | Yes |
| product functions / security – ● SSH | Yes |
| product functions / time – ● SICLOCK support | Yes |
| product functions / time – ● NTP | No |
| product functions / time – ● SNTP | Yes |
| standards, specifications, approvals – ● CE marking | Yes |
| standards, specifications, approvals – ● KC approval | Yes |
| standards, specifications, approvals – ● Regulatory Compliance Mark (RCM) | Yes |
| standards, specifications, approvals – ● for EMC interference emission | EN 61000-6-4 (Class A) |
| standards, specifications, approvals – ● for immunity to EMC | EN 61000-6-2 |
| standards, specifications, approvals – ● for safety / from CSA and UL | UL 60950-1 E115352, CSA C22.2 No. 60950-1 |
| standards, specifications, approvals / hazardous environments – ● ATEX | Yes |
| standards, specifications, approvals / hazardous environments – ● IECEx | Yes |
| standards, specifications, approvals / hazardous environments – ● ULhazloc approval | Yes |
| standards, specifications, approvals / hazardous environments – ● CCC / for hazardous zone according to GB standard | Yes |
| standards, specifications, approvals / other – ● railway application in accordance with EN 50155 | No |
| standards, specifications, approvals / other – ● railway application in accordance with EN 50124-1 | No |
| standards, specifications, approvals / other – ● RoHS conformity | Yes |
| standards, specifications, approvals / other – resistance to air pollution / conformity according to ANSI/ISA-71.04 | Yes; G3 |
| product functions / general – warranty period | 5 a |
| further information / internet links – ● to website: Selection guide for cables and connectors | https://support.industry.siemens.com/cs/ww/en/view/109766358 |
| further information / internet links – ● to web page: selection aid TIA Selection Tool | https://www.siemens.com/tstcloud |
| further information / internet links – ● to website: Industrial communication | https://www.siemens.com/simatic-net |
| further information / internet links – ● to web page: SiePortal | https://sieportal.siemens.com/ |
| further information / internet links – ● to website: Image database | https://www.automation.siemens.com/bilddb |
| further information / internet links – ● to website: CAx-Download-Manager | https://www.siemens.com/cax |
| further information / internet links – ● to website: Industry Online Support | https://support.industry.siemens.com |
| security information – security information | Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) |