product type designation – product brand nameSCALANCE
product type designation – product type designationXF202-2P IRT
product type designation – Technical Product Detail Pagehttps://i.siemens.com/1P6GK5202-2BH00-2BD2
transfer rate – transfer rate10, 100 Mbit/s
interfaces / for communication / integrated – ● for network components or terminal equipment2
interfaces / for communication / integrated – number of 100 Mbit/s SC-RJ-ports / for POF FOC / with push-pull connection system2
interfaces / other – ● for signaling contact1
interfaces / other – ● for power supply1
interfaces / other – ● for signaling contact (2)2-pole terminal block
interfaces / other – ● for power supply (2)2-pole terminal block
interfaces / other – ● C-PLUGYes
interfaces / other – ● at DC / rated value24 V
interfaces / other – ● at DC / maximum0.1 A
Напряжение питанияDC
Напряжение питания24 V
Напряжение питания7.2 W
Напряжение питания19.2 ... 28.8
Напряжение питания0.4 A
Напряжение питания2-pole terminal block
Напряжение питанияYes
Напряжение питания2.5 A (cannot be replaced by user)
ambient conditions – ● during operation0 ... 50 °C
ambient conditions – ● during storage-40 ... +70 °C
ambient conditions – ● during transport-40 ... +70 °C
ambient conditions – ● at 25 °C / without condensation / during operation / maximum95 %
ambient conditions – protection class IPIP20
Массаcompact
Масса100 mm
Масса117 mm
Масса74 mm
Масса0.25 kg
МассаYes
МассаNo
МассаNo
МассаNo
product features, product functions, product components / general – cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s50
product features, product functions, product components / general – cascading in cases of star topologyany (depending only on signal propagation time)
product functions / management, configuration, engineering – ● CLIYes
product functions / management, configuration, engineering – ● web-based managementYes
product functions / management, configuration, engineering – ● MIB supportYes
product functions / management, configuration, engineering – ● TRAPs via emailYes
product functions / management, configuration, engineering – ● configuration with STEP 7Yes
product functions / management, configuration, engineering – ● port mirroringNo
product functions / management, configuration, engineering – ● multiport mirroringNo
product functions / management, configuration, engineering – ● with IRT / PROFINET IO switchYes
product functions / management, configuration, engineering – ● PROFINET IO diagnosisYes
product functions / management, configuration, engineering – ● switch-managedYes
product functions / management, configuration, engineering – PROFINET conformity classC
product functions / management, configuration, engineering – ● TelnetYes
product functions / management, configuration, engineering – ● HTTPYes
product functions / management, configuration, engineering – ● HTTPSYes
product functions / management, configuration, engineering – ● TFTPYes
product functions / management, configuration, engineering – ● FTPYes
product functions / management, configuration, engineering – ● BOOTPNo
product functions / management, configuration, engineering – ● DCPYes
product functions / management, configuration, engineering – ● LLDPYes
product functions / management, configuration, engineering – ● SNMP v1Yes
product functions / management, configuration, engineering – ● SNMP v2Yes
product functions / management, configuration, engineering – ● SNMP v3Yes
product functions / management, configuration, engineering – ● I&M0 - device-specific informationYes
product functions / management, configuration, engineering – ● I&M1 - higher level designation/location designationYes
product functions / diagnostics – ● port diagnosticsYes
product functions / diagnostics – ● statistics Packet SizeYes
product functions / diagnostics – ● statistics packet typeYes
product functions / diagnostics – ● error statisticsYes
product functions / DHCP – ● DHCP clientYes
product functions / redundancy – protocol / is supported / Media Redundancy Protocol (MRP)Yes
product functions / redundancy – ● media redundancy protocol (MRP) with redundancy managerYes
product functions / redundancy – ● Media Redundancy Protocol for Planned Duplication (MRPD)Yes
product functions / redundancy – ● ring redundancyYes
product functions / redundancy – ● high speed redundancy protocol (HRP) with redundancy managerYes
product functions / redundancy – ● high speed redundancy protocol (HRP) with standby redundancyYes
product functions / redundancy – ● Parallel Redundancy Protocol (PRP)/operation in the PRP-networkYes
product functions / redundancy – ● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)No
product functions / redundancy – ● passive listeningYes
product functions / security – ● SSHYes
product functions / time – ● SICLOCK supportYes
product functions / time – ● NTPNo
product functions / time – ● SNTPYes
standards, specifications, approvals – ● CE markingYes
standards, specifications, approvals – ● KC approvalYes
standards, specifications, approvals – ● Regulatory Compliance Mark (RCM)Yes
standards, specifications, approvals – ● for EMC interference emissionEN 61000-6-4 (Class A)
standards, specifications, approvals – ● for immunity to EMCEN 61000-6-2
standards, specifications, approvals – ● for safety / from CSA and ULUL 60950-1 E115352, CSA C22.2 No. 60950-1
standards, specifications, approvals / hazardous environments – ● ATEXYes
standards, specifications, approvals / hazardous environments – ● IECExYes
standards, specifications, approvals / hazardous environments – ● ULhazloc approvalYes
standards, specifications, approvals / hazardous environments – ● CCC / for hazardous zone according to GB standardYes
standards, specifications, approvals / other – ● railway application in accordance with EN 50155No
standards, specifications, approvals / other – ● railway application in accordance with EN 50124-1No
standards, specifications, approvals / other – ● RoHS conformityYes
standards, specifications, approvals / other – resistance to air pollution / conformity according to ANSI/ISA-71.04Yes; G3
product functions / general – warranty period5 a
further information / internet links – ● to website: Selection guide for cables and connectorshttps://support.industry.siemens.com/cs/ww/en/view/109766358
further information / internet links – ● to web page: selection aid TIA Selection Toolhttps://www.siemens.com/tstcloud
further information / internet links – ● to website: Industrial communicationhttps://www.siemens.com/simatic-net
further information / internet links – ● to web page: SiePortalhttps://sieportal.siemens.com/
further information / internet links – ● to website: Image databasehttps://www.automation.siemens.com/bilddb
further information / internet links – ● to website: CAx-Download-Managerhttps://www.siemens.com/cax
further information / internet links – ● to website: Industry Online Supporthttps://support.industry.siemens.com
security information – security informationSiemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)
Получить предложение по этой позиции