Siemens AG 6GK5204-0BS00-3LA3
SCALANCE X-200RNA managed
Категории:
Технические характеристики
| product type designation – product brand name | SCALANCE |
|---|---|
| product type designation – product type designation | X204RNA EEC |
| product type designation – Technical Product Detail Page | https://i.siemens.com/1P6GK5204-0BS00-3LA3 |
| transfer rate – transfer rate | 10, 100 Mbit/s |
| interfaces / for communication / integrated – ● for network components or terminal equipment | 2 |
| interfaces / for communication / integrated – number of combo ports / with RJ45 interface for optical plug-in transceiver | 2 |
| interfaces / other – ● for signaling contact | 1 |
| interfaces / other – ● for power supply | 1 |
| interfaces / other – ● for signaling contact (2) | 3-pole terminal block |
| interfaces / other – ● for power supply (2) | 3-pole terminal block |
| interfaces / other – ● C-PLUG | Yes |
| interfaces / other – ● at AC / rated value | 230 V |
| interfaces / other – ● at DC / rated value | 24 V |
| interfaces / other – ● at AC / maximum | 0.1 A |
| interfaces / other – ● at DC / maximum | 0.1 A |
| Напряжение питания | Yes |
| Напряжение питания | DC |
| Напряжение питания | 24 V |
| Напряжение питания | 6 W |
| Напряжение питания | 85 ... 276 |
| Напряжение питания | 0.25 A |
| Напряжение питания | 3-pole terminal block |
| Напряжение питания | Yes |
| Напряжение питания | 1,25 A |
| Напряжение питания | AC |
| Напряжение питания | 85 ... 276 |
| ambient conditions – ● during operation | -40 ... +70 °C |
| ambient conditions – ● during storage | -40 ... +70 °C |
| ambient conditions – ● during transport | -40 ... +70 °C |
| ambient conditions – ● note | A maximum operating temperature of +85 °C is permissible for a duration of 16 hours |
| ambient conditions – ● at 25 °C / without condensation / during operation / maximum | 95 % |
| ambient conditions – protection class IP | IP20 |
| Масса | compact |
| Масса | 70 mm |
| Масса | 147 mm |
| Масса | 123 mm |
| Масса | 0.78 kg |
| Масса | Yes |
| Масса | Yes |
| Масса | No |
| Масса | No |
| Масса | No |
| product functions / management, configuration, engineering – ● CLI | Yes |
| product functions / management, configuration, engineering – ● web-based management | Yes |
| product functions / management, configuration, engineering – ● MIB support | Yes |
| product functions / management, configuration, engineering – ● TRAPs via email | Yes |
| product functions / management, configuration, engineering – ● configuration with STEP 7 | No |
| product functions / management, configuration, engineering – ● port mirroring | No |
| product functions / management, configuration, engineering – ● multiport mirroring | No |
| product functions / management, configuration, engineering – ● with IRT / PROFINET IO switch | No |
| product functions / management, configuration, engineering – ● PROFINET IO diagnosis | No |
| product functions / management, configuration, engineering – ● switch-managed | No |
| product functions / management, configuration, engineering – ● Telnet | No |
| product functions / management, configuration, engineering – ● HTTP | Yes |
| product functions / management, configuration, engineering – ● HTTPS | Yes |
| product functions / management, configuration, engineering – ● TFTP | No |
| product functions / management, configuration, engineering – ● FTP | No |
| product functions / management, configuration, engineering – ● BOOTP | No |
| product functions / management, configuration, engineering – ● GMRP | No |
| product functions / management, configuration, engineering – ● DCP | Yes |
| product functions / management, configuration, engineering – ● LLDP | No |
| product functions / management, configuration, engineering – ● SNMP v1 | Yes |
| product functions / management, configuration, engineering – ● SNMP v2 | Yes |
| product functions / management, configuration, engineering – ● SNMP v3 | Yes |
| product functions / management, configuration, engineering – ● IGMP (snooping/querier) | No |
| product functions / management, configuration, engineering – ● I&M0 - device-specific information | Yes |
| product functions / management, configuration, engineering – ● I&M1 - higher level designation/location designation | Yes |
| product functions / diagnostics – ● port diagnostics | Yes |
| product functions / diagnostics – ● statistics Packet Size | Yes |
| product functions / diagnostics – ● statistics packet type | Yes |
| product functions / diagnostics – ● error statistics | Yes |
| product functions / redundancy – protocol / is supported / Media Redundancy Protocol (MRP) | No |
| product functions / redundancy – ● media redundancy protocol (MRP) with redundancy manager | No |
| product functions / redundancy – ● ring redundancy | No |
| product functions / redundancy – ● high speed redundancy protocol (HRP) with redundancy manager | No |
| product functions / redundancy – ● high speed redundancy protocol (HRP) with standby redundancy | No |
| product functions / redundancy – ● High-availability Seamless Redundancy (HSR) | No |
| product functions / redundancy – ● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA) | Yes |
| product functions / redundancy – ● High-availability Seamless Redundancy (HSR) and Parallel Redundancy Protocol (PRP) coupling | No |
| product functions / redundancy – ● passive listening | No |
| product functions / security – ● SSH | Yes |
| product functions / time – ● SICLOCK support | No |
| product functions / time – ● NTP | No |
| product functions / time – ● SNTP | Yes |
| standards, specifications, approvals – ● CE marking | Yes |
| standards, specifications, approvals – ● UKCA marking | Yes |
| standards, specifications, approvals – ● cULus approval | Yes |
| standards, specifications, approvals – ● KC approval | Yes |
| standards, specifications, approvals – ● Regulatory Compliance Mark (RCM) | Yes |
| standards, specifications, approvals – ● for EMC | IEC 61850, IEEE 1613 |
| standards, specifications, approvals – ● for EMC interference emission | EN 61000-6-4:2001 (Class A) |
| standards, specifications, approvals – ● for immunity to EMC | EN 61000-6-4:2001 |
| standards, specifications, approvals – ● for safety / from CSA and UL | UL 508 E85972, CSA C22.2 no. 142-M1987 |
| standards, specifications, approvals / other – ● railway application in accordance with EN 50155 | Yes |
| standards, specifications, approvals / other – ● railway application in accordance with EN 50121-4 | Yes |
| standards, specifications, approvals / other – ● railway application in accordance with EN 50124-1 | No |
| standards, specifications, approvals / other – ● fire protection in accordance with EN 45545-2 | Yes |
| standards, specifications, approvals / other – ● IEC 61850-3 | Yes |
| standards, specifications, approvals / other – ● IEEE 1613 | Yes |
| standards, specifications, approvals / other – ● RoHS conformity | Yes |
| standards, specifications, approvals / marine classification – ● Royal Institution of Naval Architects (RINA) | Yes |
| product functions / general – MTBF | 67.64 a |
| product functions / general – warranty period | 5 a |
| product functions / general – product function / is supported / identification link | Yes; acc. to IEC 61406-1:2022 |
| further information / internet links – ● to website: Selection guide for cables and connectors | https://support.industry.siemens.com/cs/ww/en/view/109766358 |
| further information / internet links – ● to web page: selection aid TIA Selection Tool | https://www.siemens.com/tstcloud |
| further information / internet links – ● to website: Industrial communication | https://www.siemens.com/simatic-net |
| further information / internet links – ● to web page: SiePortal | https://sieportal.siemens.com/ |
| further information / internet links – ● to website: Image database | https://www.automation.siemens.com/bilddb |
| further information / internet links – ● to website: CAx-Download-Manager | https://www.siemens.com/cax |
| further information / internet links – ● to website: Industry Online Support | https://support.industry.siemens.com |
| security information – security information | Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) |