Siemens AG 6GK5205-3BF00-2AB2
SCALANCE XB-200 managed
Категории:
Технические характеристики
| product type designation – product brand name | SCALANCE |
|---|---|
| product type designation – product type designation | XB205-3LD |
| product type designation – Technical Product Detail Page | https://i.siemens.com/1P6GK5205-3BF00-2AB2 |
| transfer rate – transfer rate | 10, 100 Mbit/s |
| interfaces / for communication / integrated – ● for network components or terminal equipment | 5; RJ45 |
| interfaces / for communication / integrated – ● for single mode (LD) | 3 |
| interfaces / for communication / integrated – transmission method / of the optical interface | 100BaseLX LD |
| interfaces / other – ● for operator console | 1 |
| interfaces / other – ● for power supply | 1 |
| interfaces / other – ● for operator console (2) | RJ11 |
| interfaces / other – ● for management purposes | RJ45 |
| Напряжение питания | Yes |
| Напряжение питания | DC |
| Напряжение питания | 24 V |
| Напряжение питания | 7 W |
| Напряжение питания | 19.2 ... 28.8 |
| Напряжение питания | 0.29 A |
| Напряжение питания | 6-pole terminal block |
| Напряжение питания | Yes |
| ambient conditions – ● during operation | 0 ... 60 °C |
| ambient conditions – ● during storage | -40 ... +70 °C |
| ambient conditions – ● during transport | -40 ... +70 °C |
| ambient conditions – ● at 25 °C / without condensation / during operation / maximum | 95 % |
| ambient conditions – protection class IP | IP20 |
| Масса | compact |
| Масса | 80 mm |
| Масса | 117 mm |
| Масса | 109 mm |
| Масса | 0.35 kg |
| Масса | Polycarbonate (PC-GF10) |
| Масса | Yes |
| product features, product functions, product components / general – cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s | 50 |
| product features, product functions, product components / general – cascading in cases of star topology | any (depending only on signal propagation time) |
| product functions / management, configuration, engineering – ● CLI | Yes |
| product functions / management, configuration, engineering – ● web-based management | Yes |
| product functions / management, configuration, engineering – ● MIB support | Yes |
| product functions / management, configuration, engineering – ● TRAPs via email | Yes |
| product functions / management, configuration, engineering – ● configuration with STEP 7 | Yes |
| product functions / management, configuration, engineering – ● RMON | Yes |
| product functions / management, configuration, engineering – ● port mirroring | Yes |
| product functions / management, configuration, engineering – ● multiport mirroring | Yes |
| product functions / management, configuration, engineering – ● CoS | Yes |
| product functions / management, configuration, engineering – ● PROFINET IO diagnosis | Yes |
| product functions / management, configuration, engineering – ● switch-managed | Yes |
| product functions / management, configuration, engineering – PROFINET conformity class | B |
| product functions / management, configuration, engineering – network load class / according to PROFINET | III |
| product functions / management, configuration, engineering – telegram length / for Ethernet / maximum | 1632 byte |
| product functions / management, configuration, engineering – ● Telnet | Yes |
| product functions / management, configuration, engineering – ● HTTP | Yes |
| product functions / management, configuration, engineering – ● HTTPS | Yes |
| product functions / management, configuration, engineering – ● TFTP | Yes |
| product functions / management, configuration, engineering – ● SFTP | Yes |
| product functions / management, configuration, engineering – ● BOOTP | Yes |
| product functions / management, configuration, engineering – ● DCP | Yes |
| product functions / management, configuration, engineering – ● LLDP | Yes |
| product functions / management, configuration, engineering – ● EtherNet/IP | Yes |
| product functions / management, configuration, engineering – ● SNMP v1 | Yes |
| product functions / management, configuration, engineering – ● SNMP v2 | Yes |
| product functions / management, configuration, engineering – ● SNMP v3 | Yes |
| product functions / management, configuration, engineering – ● IGMP (snooping/querier) | Yes |
| product functions / management, configuration, engineering – ● I&M0 - device-specific information | Yes |
| product functions / management, configuration, engineering – ● I&M1 - higher level designation/location designation | Yes |
| product functions / diagnostics – ● port diagnostics | Yes |
| product functions / diagnostics – ● statistics Packet Size | Yes |
| product functions / diagnostics – ● statistics packet type | Yes |
| product functions / diagnostics – ● error statistics | Yes |
| product functions / diagnostics – ● SysLog | Yes |
| product functions / VLAN – ● VLAN - port based | Yes |
| product functions / VLAN – number of VLANs / maximum | 257 |
| product functions / VLAN – number of VLANs - dynamic / maximum | 257 |
| product functions / VLAN – number of VLANs / at ring redundancy (HRP; MRP; standby link) | 257 |
| product functions / DHCP – ● DHCP client | Yes |
| product functions / redundancy – protocol / is supported / Media Redundancy Protocol (MRP) | Yes |
| product functions / redundancy – ● media redundancy protocol (MRP) with redundancy manager | Yes |
| product functions / redundancy – ● Media Redundancy Protocol Interconnection (MRP-I) | Yes; LC mode |
| product functions / redundancy – ● of the PROFINET IO device / is supported / PROFINET system redundancy | No |
| product functions / redundancy – ● ring redundancy | Yes |
| product functions / redundancy – ● high speed redundancy protocol (HRP) with redundancy manager | Yes |
| product functions / redundancy – ● high speed redundancy protocol (HRP) with standby redundancy | Yes |
| product functions / redundancy – ● redundancy procedure STP | Yes |
| product functions / redundancy – ● redundancy procedure RSTP | Yes |
| product functions / redundancy – ● redundancy procedure RSTP+ | Yes |
| product functions / redundancy – ● Parallel Redundancy Protocol (PRP)/operation in the PRP-network | Yes |
| product functions / redundancy – ● passive listening | Yes |
| product functions / security – ● IEEE 802.1x (radius) | Yes |
| product functions / security – ● RADIUS client | Yes |
| product functions / security – ● broadcast/multicast/unicast limiter | Yes |
| product functions / security – ● broadcast blocking | Yes |
| product functions / security – ● SSH | Yes |
| product functions / security – ● SSL | Yes |
| product functions / time – ● SICLOCK support | Yes |
| product functions / time – ● NTP-client | Yes |
| product functions / time – ● SNTP client | Yes |
| product functions / time – ● SNTP | Yes |
| standards, specifications, approvals – ● CE marking | Yes |
| standards, specifications, approvals – ● cULus approval | Yes |
| standards, specifications, approvals – ● KC approval | Yes |
| standards, specifications, approvals – ● Regulatory Compliance Mark (RCM) | Yes |
| standards, specifications, approvals – ● for EMC interference emission | EN 61000-6-4 (Class A) |
| standards, specifications, approvals – ● for immunity to EMC | EN 61000-6-2 |
| standards, specifications, approvals – ● for safety / from CSA and UL | UL 60950-1 E115352, CSA C22.2 No. 60950-1 |
| standards, specifications, approvals / hazardous environments – ● ATEX | Yes |
| standards, specifications, approvals / hazardous environments – ● UKEX | Yes |
| standards, specifications, approvals / hazardous environments – ● IECEx | Yes |
| standards, specifications, approvals / hazardous environments – ● ULhazloc approval | Yes |
| standards, specifications, approvals / hazardous environments – ● CCC / for hazardous zone according to GB standard | Yes |
| standards, specifications, approvals / hazardous environments – ● FM registration | Yes |
| standards, specifications, approvals / other – ● RoHS conformity | Yes |
| standards, specifications, approvals / other – IT security for industrial automation systems / according to IEC 62443-4-2:2019 | Yes |
| standards, specifications, approvals / Environmental Product Declaration – Environmental Product Declaration | Yes |
| standards, specifications, approvals / Environmental Product Declaration – ● total | 260.76 kg |
| standards, specifications, approvals / Environmental Product Declaration – ● during manufacturing | 40.94 kg |
| standards, specifications, approvals / Environmental Product Declaration – ● during operation | 219.31 kg |
| standards, specifications, approvals / Environmental Product Declaration – ● after end of life | 0.51 kg |
| product functions / general – MTBF | 50 a |
| product functions / general – warranty period | 5 a |
| product functions / general – product function / is supported / identification link | Yes; acc. to IEC 61406-1:2022 |
| further information / internet links – ● to website: Selection guide for cables and connectors | https://support.industry.siemens.com/cs/ww/en/view/109766358 |
| further information / internet links – ● to web page: selection aid TIA Selection Tool | https://www.siemens.com/tstcloud |
| further information / internet links – ● to website: Industrial communication | https://www.siemens.com/simatic-net |
| further information / internet links – ● to web page: SiePortal | https://sieportal.siemens.com/ |
| further information / internet links – ● to website: Image database | https://www.automation.siemens.com/bilddb |
| further information / internet links – ● to website: CAx-Download-Manager | https://www.siemens.com/cax |
| further information / internet links – ● to website: Industry Online Support | https://support.industry.siemens.com |
| security information – security information | Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) |
| Сертификация | 40.94 kg |
| Сертификация | 219.31 kg |
| Сертификация | 0.51 kg |
| Сертификация | 260.76 kg |